Literature DB >> 18763834

Label-free electronic detection of the antigen-specific T-cell immune response.

Eric Stern1, Erin R Steenblock, Mark A Reed, Tarek M Fahmy.   

Abstract

Detection of antigen-specific T-cells is critical for diagnostic assessment and design of therapeutic strategies for many disease states. Effective monitoring of these cells requires technologies that assess their numbers as well as functional response. Current detection of antigen-specific T-cells involves flow cytometry and functional assays and requires fluorescently labeled, soluble forms of peptide-loaded major histocompatability complexes (MHC). We demonstrate that nanoscale solid-state complementary metal-oxide-semiconductor (CMOS) technology can be employed to allow direct, label-free electronic detection of antigen-specific T-cell responses within seconds after stimulation. Our approach relies on detection of extracellular acidification arising from a small number of T-cells (as few as approximately 200), whose activation is induced by triggering the T-cell antigen receptor. We show that T-cell triggering by a nonspecific anti-CD3 stimulus can be detected within 10 s after exposure to the stimulus. In contrast, antigen-specific T-cell responses are slower with response times greater than 40 s after exposure to peptide/MHC agonists. The speed and sensitivity of this technique has the potential to elucidate new understandings of the kinetics of activation-induced T-cell responses. This combined with its ease of integration into conventional electronics potentially enable rapid clinical testing and high-throughput epitope and drug screening.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18763834      PMCID: PMC2714189          DOI: 10.1021/nl801693k

Source DB:  PubMed          Journal:  Nano Lett        ISSN: 1530-6984            Impact factor:   11.189


  28 in total

1.  Increased TCR avidity after T cell activation: a mechanism for sensing low-density antigen.

Authors:  T M Fahmy; J G Bieler; M Edidin; J P Schneck
Journal:  Immunity       Date:  2001-02       Impact factor: 31.745

Review 2.  T cell receptor-MHC interactions up close.

Authors:  J Hennecke; D C Wiley
Journal:  Cell       Date:  2001-01-12       Impact factor: 41.582

3.  Continuous monitoring of receptor-mediated changes in the metabolic rates of living cells.

Authors:  J C Owicki; J W Parce; K M Kercso; G B Sigal; V C Muir; J C Venter; C M Fraser; H M McConnell
Journal:  Proc Natl Acad Sci U S A       Date:  1990-05       Impact factor: 11.205

Review 4.  Tracking T cells with tetramers: new tales from new tools.

Authors:  Paul Klenerman; Vincenzo Cerundolo; P Rod Dunbar
Journal:  Nat Rev Immunol       Date:  2002-04       Impact factor: 53.106

5.  Efficient T cell activation requires an optimal dwell-time of interaction between the TCR and the pMHC complex.

Authors:  A M Kalergis; N Boucheron; M A Doucey; E Palmieri; E C Goyarts; Z Vegh; I F Luescher; S G Nathenson
Journal:  Nat Immunol       Date:  2001-03       Impact factor: 25.606

6.  Effector function of human tumor-specific CD8 T cells in melanoma lesions: a state of local functional tolerance.

Authors:  Alfred Zippelius; Pascal Batard; Verena Rubio-Godoy; Gilles Bioley; Danielle Liénard; Ferdy Lejeune; Donata Rimoldi; Philippe Guillaume; Norbert Meidenbauer; Andreas Mackensen; Nathalie Rufer; Norbert Lubenow; Daniel Speiser; Jean-Charles Cerottini; Pedro Romero; Mikaël J Pittet
Journal:  Cancer Res       Date:  2004-04-15       Impact factor: 12.701

Review 7.  Central memory and effector memory T cell subsets: function, generation, and maintenance.

Authors:  Federica Sallusto; Jens Geginat; Antonio Lanzavecchia
Journal:  Annu Rev Immunol       Date:  2004       Impact factor: 28.527

Review 8.  Clonal sketches of the immune response.

Authors:  A Lanzavecchia
Journal:  EMBO J       Date:  1988-10       Impact factor: 11.598

9.  Detection and characterization of cellular immune responses using peptide-MHC microarrays.

Authors:  Yoav Soen; Daniel S Chen; Daniel L Kraft; Mark M Davis; Patrick O Brown
Journal:  PLoS Biol       Date:  2003-12-22       Impact factor: 8.029

Review 10.  Antigen-specific T cells: analyses of the needles in the haystack.

Authors:  Jill E Slansky
Journal:  PLoS Biol       Date:  2003-12-22       Impact factor: 8.029

View more
  12 in total

1.  Label-free biosensing with functionalized nanopipette probes.

Authors:  Senkei Umehara; Miloslav Karhanek; Ronald W Davis; Nader Pourmand
Journal:  Proc Natl Acad Sci U S A       Date:  2009-03-05       Impact factor: 11.205

2.  High-k dielectric Al₂O₃ nanowire and nanoplate field effect sensors for improved pH sensing.

Authors:  Bobby Reddy; Brian R Dorvel; Jonghyun Go; Pradeep R Nair; Oguz H Elibol; Grace M Credo; Jonathan S Daniels; Edmond K C Chow; Xing Su; Madoo Varma; Muhammad A Alam; Rashid Bashir
Journal:  Biomed Microdevices       Date:  2011-04       Impact factor: 2.838

3.  Multiplexed SOI BioFETs.

Authors:  Aleksandar Vacic; Jason M Criscione; Eric Stern; Nitin K Rajan; Tarek Fahmy; Mark A Reed
Journal:  Biosens Bioelectron       Date:  2011-07-23       Impact factor: 10.618

4.  Design and Implementation of Functional Nanoelectronic Interfaces With Biomolecules, Cells, and Tissue Using Nanowire Device Arrays.

Authors:  Brian P Timko; Tzahi Cohen-Karni; Quan Qing; Bozhi Tian; Charles M Lieber
Journal:  IEEE Trans Nanotechnol       Date:  2010-05       Impact factor: 2.570

Review 5.  A Review of Single-Cell Adhesion Force Kinetics and Applications.

Authors:  Ashwini Shinde; Kavitha Illath; Pallavi Gupta; Pallavi Shinde; Ki-Taek Lim; Moeto Nagai; Tuhin Subhra Santra
Journal:  Cells       Date:  2021-03-05       Impact factor: 6.600

6.  Controlling influenza by cytotoxic T-cells: calling for help from destroyers.

Authors:  Michael Schotsaert; Lorena Itatí Ibañez; Walter Fiers; Xavier Saelens
Journal:  J Biomed Biotechnol       Date:  2010-05-24

7.  A nanoelectronic enzyme-linked immunosorbent assay for detection of proteins in physiological solutions.

Authors:  Eric Stern; Aleksandar Vacic; Chao Li; Fumiaki N Ishikawa; Chongwu Zhou; Mark A Reed; Tarek M Fahmy
Journal:  Small       Date:  2010-01       Impact factor: 13.281

8.  A calibration method for nanowire biosensors to suppress device-to-device variation.

Authors:  Fumiaki N Ishikawa; Marco Curreli; Hsiao-Kang Chang; Po-Chiang Chen; Rui Zhang; Richard J Cote; Mark E Thompson; Chongwu Zhou
Journal:  ACS Nano       Date:  2009-12-22       Impact factor: 15.881

Review 9.  Application of nanotechnologies for improved immune response against infectious diseases in the developing world.

Authors:  Michael Look; Arunima Bandyopadhyay; Jeremy S Blum; Tarek M Fahmy
Journal:  Adv Drug Deliv Rev       Date:  2009-11-14       Impact factor: 15.470

Review 10.  CMOS cell sensors for point-of-care diagnostics.

Authors:  Yekbun Adiguzel; Haluk Kulah
Journal:  Sensors (Basel)       Date:  2012-07-25       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.