Literature DB >> 18761582

Hardness, flexural strength, and flexural modulus comparisons of three differently cured denture base systems.

Isma Liza Ali1, Norsiah Yunus, Mohamed Ibrahim Abu-Hassan.   

Abstract

PURPOSE: This study compared the surface hardness, flexural strength, and flexural modulus of a light- and heat-cured urethane dimethacrylate (UDMA) to two conventional polymethyl methacrylate (PMMA) denture base resins. The effect of less-than-optimal processing condition on the hardness of internal and external surfaces of UDMA specimens was also investigated.
MATERIALS AND METHODS: The materials tested were Eclipse (light- and heat-cured UDMA), Meliodent (heat-cured PMMA), and Probase Cold (auto-cured PMMA). Eclipse specimens were prepared by adapting the material onto the master cast and light curing in the processing unit for 10 minutes. Meliodent and Probase Cold specimens were prepared according to the manufacturers' instructions. Twenty rectangular specimens measuring 65 x 10 x 2.5 mm(3) were prepared for each material. They were stored in water at 37 degrees C for 30 days before testing. The surface hardness was measured using Vickers Hardness (VHN) test, and flexural strength and flexural modulus were measured using a 3-point bending test. Twenty-five additional Eclipse specimens were similarly prepared and were processed at various times of less than 20 minutes of curing. Vickers Hardness was determined on both the external and internal surfaces of specimens. Data were analyzed using a one-way ANOVA for comparisons of hardness, flexural strength, and flexural modulus between the three denture base materials and for hardness values of both the internal and external surface of Eclipse specimens with curing times. Post hoc analyses (Scheffé test) determined the difference between the groups. Student t-test was used for comparison of hardness between the external and internal surfaces of Eclipse specimens.
RESULTS: The hardness (VHN) values were 19.4 +/- 0.7, 17.0 +/- 0.4, and 16.0 +/- 0.4; the flexural strengths (MPa) were 103 +/- 4, 78 +/- 3, and 63 +/- 4; and the flexural moduli (MPa) were 2498 +/- 143, 1969 +/- 55, and 1832 +/- 89 for Eclipse, Meliodent, and Probase Cold materials, respectively. A comparison among the three polymers showed there were significant differences in surface hardness, flexural strength, and flexural modulus (p < 0.05). No significant difference in surface hardness (VHN) between the internal (19.1 +/- 0.6 to 19.4 +/- 0.7) and external surfaces (18.9 +/- 0.4 to 19.2 +/- 0.6) of irradiated Eclipse specimens was observed at 10-, 12-, and 14-minute polymerization times.
CONCLUSION: The surface hardness, flexural strength, and flexural modulus of light- and heat-cured UDMA (Eclipse) were significantly higher than the values obtained for heat-only cured (Meliodent) and auto-cured (Probase Cold) PMMA denture base systems.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18761582     DOI: 10.1111/j.1532-849X.2008.00357.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  21 in total

1.  Tensile bond strength of silicone-based soft denture liner to two chemically different denture base resins after various surface treatments.

Authors:  Hakan Akin; Faik Tugut; Umit Guney; Omer Kirmali; Turker Akar
Journal:  Lasers Med Sci       Date:  2012-03-25       Impact factor: 3.161

2.  Flexural Properties, Impact Strength, and Hardness of Nanodiamond-Modified PMMA Denture Base Resin.

Authors:  Shaimaa M Fouda; Mohammed M Gad; Passent Ellakany; Maram A Al Ghamdi; Soban Q Khan; Sultan Akhtar; Mohamed S Ali; Fahad A Al-Harbi
Journal:  Int J Biomater       Date:  2022-07-09

3.  The residual monomer content and mechanical properties of CAD\CAM resins used in the fabrication of complete dentures as compared to heat cured resins.

Authors:  Al-Dharrab Ayman
Journal:  Electron Physician       Date:  2017-07-25

4.  Analysis of bond strength between a nylon reinforcement structure and dental resins.

Authors:  Leonardo-Jiro-Nomura Nakano; Guilherme-da Rocha-Scalzer Lopes; Aline-Silva Firmino; Jefferson-David-Melo de Matos; Rubens-Nisie Tango; Tarcisio-José-de Arruda Paes-Junior
Journal:  J Clin Exp Dent       Date:  2021-05-01

5.  Flexural properties of a light-cure and a self-cure denture base materials compared to conventional alternatives.

Authors:  Emre Mumcu; Altug Cilingir; Burc Gencel; Tonguc Sülün
Journal:  J Adv Prosthodont       Date:  2011-09-25       Impact factor: 1.904

6.  Argon Ion Laser Polymerized Acrylic Resin: A Comparative Analysis of Mechanical Properties of Laser Cured, Light Cured and Heat Cured Denture Base Resins.

Authors:  S Srinivasa Murthy; Gargi S Murthy
Journal:  J Int Oral Health       Date:  2015-06

7.  Effect of surface treatments on shear bond strength of denture teeth to denture base resins.

Authors:  Farideh Bahrani; Amir Ali Reza Khaledi
Journal:  Dent Res J (Isfahan)       Date:  2014-01

Review 8.  Polyamide as a Denture Base Material: A Literature Review.

Authors:  Mahroo Vojdani; Rashin Giti
Journal:  J Dent (Shiraz)       Date:  2015-03

9.  Impact of household vinegar on calculus removal and mechanical properties of orthodontic resin.

Authors:  Binit Shrestha; Wassana Wichai; Toemsak Srikhirin; Surachai Dechkunakorn; Niwat Anuwongnukroh
Journal:  J Orofac Orthop       Date:  2020-10-26       Impact factor: 1.938

10.  Flexural Strength and Hardness of Filler-Reinforced PMMA Targeted for Denture Base Application.

Authors:  Abdulaziz Alhotan; Julian Yates; Saleh Zidan; Julfikar Haider; Nikolaos Silikas
Journal:  Materials (Basel)       Date:  2021-05-19       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.