Literature DB >> 18759367

Magnetization transfer induced biexponential longitudinal relaxation.

Andrew M Prantner1, G Larry Bretthorst, Jeffrey J Neil, Joel R Garbow, Joseph J H Ackerman.   

Abstract

Longitudinal relaxation of brain water (1)H magnetization in mammalian brain in vivo is typically analyzed on a per-voxel basis using a monoexponential model, thereby assigning a single relaxation time constant to all (1)H magnetization within a given voxel. This approach was tested by obtaining inversion recovery (IR) data from gray matter of rats at 64 exponentially spaced recovery times. Using Bayesian probability for model selection, brain water data were best represented by a biexponential function characterized by fast and slow relaxation components. At 4.7T, the amplitude fraction of the rapidly relaxing component is 3.4% +/- 0.7% with a rate constant of 44 +/- 12 s(-1) (mean +/- SD; 174 voxels from four rats). The rate constant of the slow relaxing component is 0.66 +/- 0.04 s(-1). At 11.7T, the corresponding values are 6.9% +/- 0.9%, 19 +/- 5 s(-1), and 0.48 +/- 0.02 s(-1) (151 voxels from four rats). Several putative mechanisms for biexponential relaxation behavior were evaluated, and magnetization transfer (MT) between bulk water protons and nonaqueous protons was determined to be the source of biexponential longitudinal relaxation. MR methods requiring accurate quantification of longitudinal relaxation may need to take this effect explicitly into account.

Entities:  

Mesh:

Year:  2008        PMID: 18759367      PMCID: PMC2702166          DOI: 10.1002/mrm.21671

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  23 in total

1.  Absolute cerebral blood volume and blood flow measurements based on synchrotron radiation quantitative computed tomography.

Authors:  Jean-François Adam; Hélène Elleaume; Géraldine Le Duc; Stéphanie Corde; Anne-Marie Charvet; Irène Troprès; Jean-François Le Bas; François Estève
Journal:  J Cereb Blood Flow Metab       Date:  2003-04       Impact factor: 6.200

Review 2.  Biophysical basis of magnetic resonance imaging of small animals.

Authors:  Bruce M Damon; John C Gore
Journal:  Methods Enzymol       Date:  2004       Impact factor: 1.600

3.  Perfusion imaging with NMR contrast agents.

Authors:  B R Rosen; J W Belliveau; J M Vevea; T J Brady
Journal:  Magn Reson Med       Date:  1990-05       Impact factor: 4.668

4.  Applicability of magnetization transfer nuclear magnetic resonance to study chemical exchange reactions.

Authors:  J J Led; H Gesmar; F Abildgaard
Journal:  Methods Enzymol       Date:  1989       Impact factor: 1.600

5.  The effects of changes in PaCO2 on cerebral blood volume, blood flow, and vascular mean transit time.

Authors:  R L Grubb; M E Raichle; J O Eichling; M M Ter-Pogossian
Journal:  Stroke       Date:  1974 Sep-Oct       Impact factor: 7.914

6.  Magnetization transfer in cross-linked bovine serum albumin solutions at 200 MHz: a model for tissue.

Authors:  S H Koenig; R D Brown; R Ugolini
Journal:  Magn Reson Med       Date:  1993-03       Impact factor: 4.668

7.  On the treatment of the transient response of a heterogeneous spin system to selective RF saturation.

Authors:  H N Yeung
Journal:  Magn Reson Med       Date:  1993-07       Impact factor: 4.668

8.  Quantitative interpretation of magnetization transfer.

Authors:  R M Henkelman; X Huang; Q S Xiang; G J Stanisz; S D Swanson; M J Bronskill
Journal:  Magn Reson Med       Date:  1993-06       Impact factor: 4.668

Review 9.  A review of 1H nuclear magnetic resonance relaxation in pathology: are T1 and T2 diagnostic?

Authors:  P A Bottomley; C J Hardy; R E Argersinger; G Allen-Moore
Journal:  Med Phys       Date:  1987 Jan-Feb       Impact factor: 4.071

10.  Recognition of cancer in vivo by nuclear magnetic resonance.

Authors:  I D Weisman; L H Bennett; L R Maxwell; M W Woods; D Burk
Journal:  Science       Date:  1972-12-22       Impact factor: 47.728

View more
  21 in total

1.  Visualization of intra-thalamic nuclei with optimized white-matter-nulled MPRAGE at 7T.

Authors:  Thomas Tourdias; Manojkumar Saranathan; Ives R Levesque; Jason Su; Brian K Rutt
Journal:  Neuroimage       Date:  2013-09-07       Impact factor: 6.556

2.  Non-contrast myocardial infarct scar assessment using a hybrid native T1 and magnetization transfer imaging sequence at 1.5T.

Authors:  Chong Duan; Yanjie Zhu; Jihye Jang; Jennifer Rodriguez; Ulf Neisius; Ahmed S Fahmy; Reza Nezafat
Journal:  Magn Reson Med       Date:  2018-12-18       Impact factor: 4.668

3.  Rapid high-resolution three-dimensional mapping of T1 and age-dependent variations in the non-human primate brain using magnetization-prepared rapid gradient-echo (MPRAGE) sequence.

Authors:  Junjie V Liu; Nicholas A Bock; Afonso C Silva
Journal:  Neuroimage       Date:  2011-03-03       Impact factor: 6.556

Review 4.  Studying brain microstructure with magnetic susceptibility contrast at high-field.

Authors:  Jeff H Duyn
Journal:  Neuroimage       Date:  2017-02-24       Impact factor: 6.556

5.  Magnetic resonance microdynamic imaging reveals distinct tissue microenvironments.

Authors:  Dan Benjamini; Peter J Basser
Journal:  Neuroimage       Date:  2017-09-22       Impact factor: 6.556

6.  Multi-parametric MRI characterization of inflammation in murine skeletal muscle.

Authors:  Nathan D Bryant; Ke Li; Mark D Does; Stephanie Barnes; Daniel F Gochberg; Thomas E Yankeelov; Jane H Park; Bruce M Damon
Journal:  NMR Biomed       Date:  2014-04-29       Impact factor: 4.044

7.  Evaluation and comparison of diffusion MR methods for measuring apparent transcytolemmal water exchange rate constant.

Authors:  Xin Tian; Hua Li; Xiaoyu Jiang; Jingping Xie; John C Gore; Junzhong Xu
Journal:  J Magn Reson       Date:  2016-12-01       Impact factor: 2.229

8.  Analysis and correction of biases in cross-relaxation MRI due to biexponential longitudinal relaxation.

Authors:  Pouria Mossahebi; Vasily L Yarnykh; Alexey Samsonov
Journal:  Magn Reson Med       Date:  2014-02       Impact factor: 4.668

9.  The radial diffusivity and magnetization transfer pool size ratio are sensitive markers for demyelination in a rat model of type III multiple sclerosis (MS) lesions.

Authors:  Vaibhav A Janve; Zhongliang Zu; Song-Yi Yao; Ke Li; Fang Lin Zhang; Kevin J Wilson; Xiawei Ou; Mark D Does; Sriram Subramaniam; Daniel F Gochberg
Journal:  Neuroimage       Date:  2013-02-26       Impact factor: 6.556

10.  Simultaneous multi-angular relaxometry of tissue with MRI (SMART MRI): Theoretical background and proof of concept.

Authors:  Alexander L Sukstanskii; Jie Wen; Anne H Cross; Dmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2016-03-15       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.