Literature DB >> 3031439

A review of 1H nuclear magnetic resonance relaxation in pathology: are T1 and T2 diagnostic?

P A Bottomley, C J Hardy, R E Argersinger, G Allen-Moore.   

Abstract

The longitudinal (T1) and transverse (T2) proton (1H) nuclear magnetic resonance (NMR) relaxation times of pathological human and animal tissues in the frequency range 1-100 MHz are archived, reviewed, and analyzed as a function of tissue of origin, NMR frequency, temperature, species, and in vivo versus in vitro status. T1 data from specific disease states of the bone, brain, breast, kidney, liver, muscle, pancreas, and spleen can be characterized by simple dispersions of the form T1 = AvB in the range 1-100 MHz with A and B empirically determined pathology-dependent constants. Pathological tissue T2 values are essentially independent of NMR frequency. Raw relaxation data, best-fit T1 parameters A and B, and the mean T2 values, are tabulated along with standard deviations and sample size to establish the normal range of pathological tissue relaxation times applicable to NMR imaging or in vitro NMR examination. Statistical analysis of relaxation data, assumed independent, reveals that most tumor and edematous tissue T1 values and some breast, liver, and muscle tumor T2 values are significantly elevated (p greater than or equal to 0.95) relative to normal, but do not differ significantly from other tumors and pathologies. Statistically significant abnormalities in the T1 values of some brain, breast, and lung tumors, and most pathological tissue T2 values could not, however, be demonstrated in the presence of large statistical errors. Both T1 and T2 in uninvolved tissue from tumor-bearing animals or organs do not demonstrate statistically significant differences from normal when considered as a group, suggesting no appreciable systemic effects associated with the presence of tumors compared to the statistical uncertainty. Statistical prediction analysis for both T1 and T2 indicates that of all the tissues studied, only liver hepatoma can be reliably distinguished from normal liver based on a single T1 measurement (p greater than or equal to 0.95) given the scatter in the current published data. Indeed, data scatter, not easily attributable to temperature, species, in vivo versus in vitro status, the inclusion of implanted or chemical induced tumors, or the possible existence of multiple component relaxation, is recognized as the major factor inhibiting the diagnostic utility of quantitative NMR relaxation measurements. Malignancy indexes that combine T1 and T2 data as a diagnostic indicator suffer similar problems of uncertainty. The literature review reveals a dearth of information on the temperature and frequency dependence of pathological tissue relaxation and the possible existence of multiple relaxation components.(ABSTRACT TRUNCATED AT 400 WORDS)

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3031439     DOI: 10.1118/1.596111

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  70 in total

1.  1H spin-lattice relaxation parameters in the length of human intestine resected for cancer.

Authors:  P Fantazzini; A Sarra
Journal:  MAGMA       Date:  1996 Sep-Dec       Impact factor: 2.310

2.  Novel whole brain segmentation and volume estimation using quantitative MRI.

Authors:  J West; J B M Warntjes; P Lundberg
Journal:  Eur Radiol       Date:  2011-11-24       Impact factor: 5.315

3.  Towards quantitative measurements of relaxation times and other parameters in the brain.

Authors:  P S Tofts; E P du Boulay
Journal:  Neuroradiology       Date:  1990       Impact factor: 2.804

4.  NMR spin grouping and correlation exchange analysis. Application to low hydration NaDNA paracrystals.

Authors:  L J Schreiner; J C MacTavish; M M Pintar; A Rupprecht
Journal:  Biophys J       Date:  1991-01       Impact factor: 4.033

5.  Time spatial labeling inversion pulse cerebral MR angiography without subtraction by use of dual inversion recovery background suppression.

Authors:  Yoshiyuki Ishimori; Masahiko Monma; Hiraku Kawamura; Tomoko Miyata
Journal:  Radiol Phys Technol       Date:  2010-12-01

6.  MDEFT imaging of the human brain at 8 T.

Authors:  D G Norris; A Kangarlu; C Schwarzbauer; A M Abduljalil; G Christoforidis; P M Robitaille
Journal:  MAGMA       Date:  1999-10       Impact factor: 2.310

7.  Anthropomorphic breast phantoms for testing elastography systems.

Authors:  Ernest L Madsen; Maritza A Hobson; Gary R Frank; Hairong Shi; Jingfeng Jiang; Timothy J Hall; Tomy Varghese; Marvin M Doyley; John B Weaver
Journal:  Ultrasound Med Biol       Date:  2006-06       Impact factor: 2.998

8.  Studies of the T1 and T2 of intracellular water as a function of frequency in normal and transformed fetal cells.

Authors:  D E Callahan; T L Trapane; S F Deamond; G Kao; P O Ts'o; L S Kan
Journal:  Cell Biophys       Date:  1991-06

9.  Invasive breast cancer: predicting disease recurrence by using high-spatial-resolution signal enhancement ratio imaging.

Authors:  Ka-Loh Li; Savannah C Partridge; Bonnie N Joe; Jessica E Gibbs; Ying Lu; Laura J Esserman; Nola M Hylton
Journal:  Radiology       Date:  2008-07       Impact factor: 11.105

Review 10.  Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers.

Authors:  Jessica Wahsner; Eric M Gale; Aurora Rodríguez-Rodríguez; Peter Caravan
Journal:  Chem Rev       Date:  2018-10-16       Impact factor: 60.622

View more