Literature DB >> 18757957

Evaluation of impingement of the anterior tibial post during gait in a posteriorly-stabilised total knee replacement.

S Hamai1, H Miura, H Higaki, T Shimoto, S Matsuda, Y Iwamoto.   

Abstract

Mechanical failure because of wear or fracture of the polyethylene tibial post in posteriorly-stabilised total knee replacements has been extensively described. In this study of 12 patients with a clinically and radiologically successful NexGen LPS posteriorly-stabilised prosthesis impingement of the anterior tibial post was evaluated in vivo in three dimensions during gait using radiologically-based image-matching techniques. Impingement was observed in all images of the patients during the stance phase, although the NexGen LPS was designed to accommodate 14 degrees of hyperextension of the component before impingement occurred. Impingement arises as a result of posterior translation of the femur during the stance phase. Further attention must therefore be given to the configuration of the anterior portion of the femoral component and the polyethylene post when designing posteriorly-stabilised total knee replacements.

Entities:  

Mesh:

Year:  2008        PMID: 18757957     DOI: 10.1302/0301-620X.90B9.20298

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  12 in total

1.  Increased flexion position of the femoral component reduces the flexion gap in total knee arthroplasty.

Authors:  Georg Matziolis; Robert Hube; Carsten Perka; Doerte Matziolis
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-22       Impact factor: 4.342

2.  The effect of posterior tibial slope on knee flexion in posterior-stabilized total knee arthroplasty.

Authors:  Xiaojun Shi; Bin Shen; Pengde Kang; Jing Yang; Zongke Zhou; Fuxing Pei
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-06-02       Impact factor: 4.342

3.  Implant design influences tibial post wear damage in posterior-stabilized knees.

Authors:  Mark M Dolan; Natalie H Kelly; Joseph T Nguyen; Timothy M Wright; Steven B Haas
Journal:  Clin Orthop Relat Res       Date:  2011-01       Impact factor: 4.176

4.  Factors affecting range of motion after total knee arthroplasty in patients with more than 120 degrees of preoperative flexion angle.

Authors:  Kazuya Sugitani; Yuji Arai; Hisatake Takamiya; Ryu Terauchi; Shuji Nakagawa; Keiichiro Ueshima; Toshikazu Kubo
Journal:  Int Orthop       Date:  2015-02-27       Impact factor: 3.075

5.  Bone-femoral component interface gap after sagittal mechanical axis alignment is filled with new bone after cementless total knee arthroplasty.

Authors:  Shinichi Kuriyama; Katsufumi Hyakuna; Satoshi Inoue; Yasutsugu Kawai; Yasuyuki Tamaki; Hiromu Ito; Shuichi Matsuda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-02-14       Impact factor: 4.342

6.  Knee kinematics in bi-cruciate stabilized total knee arthroplasty during squatting and stair-climbing activities.

Authors:  Koji Murakami; Satoshi Hamai; Ken Okazaki; Hirotaka Gondo; Yifeng Wang; Satoru Ikebe; Hidehiko Higaki; Takeshi Shimoto; Hideki Mizu-Uchi; Yukio Akasaki; Yasuharu Nakashima
Journal:  J Orthop       Date:  2018-05-07

7.  In vivo kinematics of gait in posterior-stabilized and bicruciate-stabilized total knee arthroplasties using image-matching techniques.

Authors:  Koji Murakami; Satoshi Hamai; Ken Okazaki; Yifeng Wang; Satoru Ikebe; Hidehiko Higaki; Takeshi Shimoto; Hideki Mizu-Uchi; Yukio Akasaki; Yasuharu Nakashima
Journal:  Int Orthop       Date:  2018-04-05       Impact factor: 3.075

8.  No influence of coronal laxity and alignment on lift-off after well-balanced and aligned total knee arthroplasty.

Authors:  Satoshi Hamai; Hiromasa Miura; Ken Okazaki; Takeshi Shimoto; Hidehiko Higaki; Yukihide Iwamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-04-17       Impact factor: 4.342

Review 9.  Anterior knee pain following primary total knee arthroplasty.

Authors:  David Shervin; Katelyn Pratt; Travis Healey; Samantha Nguyen; William M Mihalko; Mouhanad M El-Othmani; Khaled J Saleh
Journal:  World J Orthop       Date:  2015-11-18

10.  Severe impingement of lumbar disc replacements increases the functional biological activity of polyethylene wear debris.

Authors:  Ryan M Baxter; Daniel W Macdonald; Steven M Kurtz; Marla J Steinbeck
Journal:  J Bone Joint Surg Am       Date:  2013-06-05       Impact factor: 5.284

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.