Literature DB >> 1875209

Influence of prosthetic joint line position on knee kinematics and patellar position.

I Yoshii1, L A Whiteside, S E White, M T Milliano.   

Abstract

Prosthetic joint line position after total knee arthroplasty (TKA) was investigated using sagittal roentgenograms obtained from six fresh frozen cadaver knees. A specially designed knee testing device was developed that allowed for a controlled flexion angle while maintaining a constant quadriceps force. Pre- and postoperative roentgenograms were obtained from 30 degrees to 120 degrees in 15 degrees intervals. Steinman pins inserted into the medial femoral condyle and patella were used as reference points in the roentgenograms. A displacement vector between the medial femoral condyle and tibial plateau was used to analyze the tibiofemoral joint relationship. The functional patellar length (Insall-Salvati ratio), was used to determine correct patellar height. Another displacement vector was used to measure the patellofemoral joint relationship, and the angle between the patellar cut surface and femoral long axis was also calculated. Bone resection thickness from the femoral, tibial, and patellar surfaces was equal to the prosthetic thickness. This reconstructive scheme produced correct ligament balance and flexibility of the knee without the aid of tensioning devices or special measurements. Patellar tracking appeared to be identical before and after surgery. This accurate but simple surgical technique also reproduced normal knee extensor mechanisms that may influence longevity and long-term results of TKA.

Entities:  

Mesh:

Year:  1991        PMID: 1875209     DOI: 10.1016/s0883-5403(11)80013-6

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  27 in total

1.  Posterior cruciate ligament function following total knee arthroplasty: the effect of joint line elevation.

Authors:  G J Emodi; J J Callaghan; D R Pedersen; T D Brown
Journal:  Iowa Orthop J       Date:  1999

2.  Restoration of the distal femur impacts patellar height in revision TKA.

Authors:  Saurabh Khakharia; Giles R Scuderi
Journal:  Clin Orthop Relat Res       Date:  2012-01       Impact factor: 4.176

Review 3.  No difference in mechanical alignment and femoral component placement between patient-specific instrumentation and conventional instrumentation in TKA.

Authors:  Huichao Fu; Jiaxing Wang; Shenyuan Zhou; Tao Cheng; Wen Zhang; Qi Wang; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-06-11       Impact factor: 4.342

4.  Joint line is well restored when navigation surgery is performed for total knee arthroplasty.

Authors:  A Ensini; F Catani; N Biasca; C Belvedere; S Giannini; A Leardini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-05-28       Impact factor: 4.342

Review 5.  Causes of failure and etiology of painful primary total knee arthroplasty.

Authors:  Romain Seil; Dietrich Pape
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-08-11       Impact factor: 4.342

6.  Comparison of joint line position changes after primary bilateral total knee arthroplasty performed using the navigation-assisted measured gap resection or gap balancing techniques.

Authors:  Han Jun Lee; Jae Sung Lee; Ho Joong Jung; Kwang Sup Song; Jae Jun Yang; Chi Woo Park
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-03-23       Impact factor: 4.342

7.  The shape and orientation of the trochlea run more parallel to the posterior condylar line than generally believed.

Authors:  C Vercruysse; H Vandenneucker; J Bellemans; L Scheys; T Luyckx
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-08-28       Impact factor: 4.342

8.  No benefit of patient-specific instrumentation in TKA on functional and gait outcomes: a randomized clinical trial.

Authors:  Matthew P Abdel; Sébastien Parratte; Guillaume Blanc; Matthieu Ollivier; Vincent Pomero; Elke Viehweger; Jean-Noël A Argenson
Journal:  Clin Orthop Relat Res       Date:  2014-03-07       Impact factor: 4.176

9.  Pseudo-patella baja: a minor yet frequent complication of total knee arthroplasty.

Authors:  Giulia Bugelli; Francesco Ascione; Niki Cazzella; Edoardo Franceschetti; Francesco Franceschi; Giacomo Dell'Osso; Eleonor Svantesson; Kristian Samuelsson; Stefano Giannotti
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-12-23       Impact factor: 4.342

10.  Patient-specific guides do not improve accuracy in total knee arthroplasty: a prospective randomized controlled trial.

Authors:  Jan Victor; Jan Dujardin; Hilde Vandenneucker; Nele Arnout; Johan Bellemans
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.