Temporary metallic stent placement in the treatment of refractory benign esophageal strictures: results and factors associated with outcome in 55 patients.

Jin Hyoung Kim1, Ho-Young Song, Eugene K Choi, Kyung Rae Kim, Ji Hoon Shin, Jin-Oh Lim.   

Abstract

The purpose of this study was to evaluate the effectiveness of temporary metallic stenting in 55 patients with treatment-resistant benign esophageal strictures and to identify factors associated with clinical outcomes. Under fluoroscopic guidance, covered retrievable stents were placed in 55 patients with benign esophageal strictures and were removed with retrieval hook 1 week to 6 months after placement. Stent placement was successful in all patients, and the mean dysphagia score was reduced from 2.8 to 1.3 (p<0.001). The most common complications were tissue hyperproliferation (31%), severe pain (24%), and stent migration (25%). During follow-up (mean: 38 months), recurrence of the stricture necessitating balloon dilation was seen in 38 (69%) of 55 patients. Maintained patency rates after temporary stenting at 1, 3, and 6 months and 1, 2, and 4 years were 58%, 43%, 38%, 33%, 26%, and 21%, respectively. In multivariate analysis, length (p=0.003) of the stricture was the only significant factor associated with maintained patency after temporary stenting. In conclusion, temporary metallic stenting for refractory benign esophageal strictures may be effective during the period of stent placement, but is disadvantaged by the high recurrence rates after stent removal, particularly in patients with a long length of stricture (>7 cm).

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18726598     DOI: 10.1007/s00330-008-1151-2

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  26 in total

1.  Temporary placement of an expandable polyester silicone-covered stent for treatment of refractory benign esophageal strictures.

Authors:  Alessandro Repici; Massimo Conio; Claudio De Angelis; Edda Battaglia; Alessandro Musso; Rinaldo Pellicano; Matteo Goss; Giovanna Venezia; Mario Rizzetto; Giorgio Saracco
Journal:  Gastrointest Endosc       Date:  2004-10       Impact factor: 9.427

2.  Surgical management of peptic esophageal stricture. Twenty-year experience.

Authors:  C D Mercer; L D Hill
Journal:  J Thorac Cardiovasc Surg       Date:  1986-03       Impact factor: 5.209

3.  Surgical management of esophageal strictures.

Authors:  A G Little; K S Naunheim; M K Ferguson; D B Skinner
Journal:  Ann Thorac Surg       Date:  1988-02       Impact factor: 4.330

4.  Covered retrievable expandable nitinol stents in patients with benign esophageal strictures: initial experience.

Authors:  H Y Song; H Y Jung; S I Park; S B Kim; D H Lee; S G Kang; Y Il Min
Journal:  Radiology       Date:  2000-11       Impact factor: 11.105

5.  Evolving role of self-expanding metal stents in the treatment of malignant dysphagia and fistulas.

Authors:  William A Ross; Firas Alkassab; Patrick M Lynch; Gregory D Ayers; Jaffer Ajani; Jeffrey H Lee; Mike Bismar
Journal:  Gastrointest Endosc       Date:  2007-01       Impact factor: 9.427

6.  Factors influencing clinical applications of endoscopic balloon dilation for benign esophageal strictures.

Authors:  Y-C Chiu; C-C Hsu; K-W Chiu; S-K Chuah; C-S Changchien; K-L Wu; Y-P Chou
Journal:  Endoscopy       Date:  2004-07       Impact factor: 10.093

Review 7.  Corrosive ingestion in adults.

Authors:  Kovil Ramasamy; Vivek V Gumaste
Journal:  J Clin Gastroenterol       Date:  2003-08       Impact factor: 3.062

8.  Use of self-expandable metallic stents in benign GI diseases.

Authors:  Raju P Wadhwa; Richard A Kozarek; Renee E France; John J Brandabur; Michael Gluck; Donald E Low; L William Traverso; Ravi Moonka; William L Traverso
Journal:  Gastrointest Endosc       Date:  2003-08       Impact factor: 9.427

9.  Recurrent traumatic urethral strictures near the external sphincter: treatment with a covered, retrievable, expandable nitinol stent--initial results.

Authors:  Ho-Young Song; Hyungkeun Park; Tae-Suk Suh; Gi-Young Ko; Tae-Hyung Kim; Eun-Sang Kim; Taehan Park
Journal:  Radiology       Date:  2003-02       Impact factor: 11.105

10.  Use of large-diameter metallic stents to seal traumatic nonmalignant perforations of the esophagus.

Authors:  Peter D Siersema; Marjolein Y V Homs; Jelle Haringsma; Huug W Tilanus; Ernst J Kuipers
Journal:  Gastrointest Endosc       Date:  2003-09       Impact factor: 9.427

View more
  30 in total

1.  Endoscopic balloon dilatation for benign fibrotic strictures after curative nonsurgical treatment for esophageal cancer.

Authors:  Yusuke Yoda; Tomonori Yano; Kazuhiro Kaneko; Shinya Tsuruta; Yasuhiro Oono; Takashi Kojima; Keiko Minashi; Hiroaki Ikematsu; Atsushi Ohtsu
Journal:  Surg Endosc       Date:  2012-04-28       Impact factor: 4.584

2.  What is the optimal duration of stent placement for refractory, benign esophageal strictures?

Authors:  Peter D Siersema; Meike M C Hirdes
Journal:  Nat Clin Pract Gastroenterol Hepatol       Date:  2009-02-10

3.  Indwelling esophageal balloon catheter for benign esophageal stenosis in infants and children.

Authors:  David van der Zee; Caroline Hulsker
Journal:  Surg Endosc       Date:  2013-11-08       Impact factor: 4.584

4.  Metal stenting to resolve post-photodynamic therapy stricture in early esophageal cancer.

Authors:  Young Koog Cheon
Journal:  World J Gastroenterol       Date:  2011-03-14       Impact factor: 5.742

Review 5.  Useful strategies to prevent severe stricture after endoscopic submucosal dissection for superficial esophageal neoplasm.

Authors:  Kaname Uno; Katsunori Iijima; Tomoyuki Koike; Tooru Shimosegawa
Journal:  World J Gastroenterol       Date:  2015-06-21       Impact factor: 5.742

6.  Clinical outcomes of self-expandable stent placement for benign esophageal diseases: A pooled analysis of the literature.

Authors:  Emo E van Halsema; Jeanin E van Hooft
Journal:  World J Gastrointest Endosc       Date:  2015-02-16

7.  Micro-endoscopy for Live Small Animal Fluorescent Imaging.

Authors:  Bjorn Paulson; Jun Ki Kim
Journal:  Adv Exp Med Biol       Date:  2021       Impact factor: 2.622

8.  Preventing stricture formation by covered esophageal stent placement after endoscopic submucosal dissection for early esophageal cancer.

Authors:  Jing Wen; Zhongsheng Lu; Yunsheng Yang; Qingsen Liu; Jing Yang; Shufang Wang; Xiangdong Wang; Hong Du; Jiangyun Meng; Hongbin Wang; Enqiang Linghu
Journal:  Dig Dis Sci       Date:  2013-12-10       Impact factor: 3.199

9.  Newly designed "pieced" stent in a rabbit model of benign esophageal stricture.

Authors:  Jin Liu; Liang Shang; Ji-Yong Liu; Cheng-Yong Qin
Journal:  World J Gastroenterol       Date:  2015-07-28       Impact factor: 5.742

10.  Benign esophageal stricture after thermal injury treated with esophagectomy and ileocolon interposition.

Authors:  Toshihiro Kitajima; Kota Momose; Seigi Lee; Shusuke Haruta; Hisashi Shinohara; Masaki Ueno; Takeshi Fujii; Harushi Udagawa
Journal:  World J Gastroenterol       Date:  2014-07-21       Impact factor: 5.742