Jin Liu1, Liang Shang1, Ji-Yong Liu1, Cheng-Yong Qin1. 1. Jin Liu, Ji-Yong Liu, Cheng-Yong Qin, Department of Gastroenterology, Shandong Provincial Hospital Affiliated to Shandong University, Jinan 250021, Shandong Province, China.
Abstract
AIM: To investigate a newly designed stent and its dilatation effect in a rabbit model of benign esophageal stricture. METHODS: Thirty-four New Zealand white rabbits underwent a corrosive injury in the middle esophagus for esophageal stricture formation. Thirty rabbits with a successful formation of esophageal strictures were randomly allocated into two groups. The control group (n = 15) was implanted with a conventional stent, and the study group (n = 15) was implanted with a detachable "pieced" stent. The study stent (30 mm in length, 10 mm in diameter) was composed of three covered metallic pieces connected by surgical suture lines. The stent was collapsed by pulling the suture lines out of the mesh. Two weeks after stricture formation, endoscopic placement of a conventional stent or the new stent was performed. Endoscopic extraction was carried out four weeks later. The extraction rate, ease of extraction, migration, complications, and survival were evaluated. RESULTS: Stent migration occurred in 3/15 (20%) animals in the control group and 2/15 (13%) animals in the study group; the difference between the two groups was not statistically significant. At the end of four weeks, the remaining stents were successfully extracted with the endoscope in 100% (11/11) of the animals in the study group, and 60% (6/10) of the animals in the control group; this difference was statistically significant (P < 0.05). There was no difference in the mean number of follow-up days between the control and study groups (25.33 vs 25.85). Minor bleeding was reported in five cases in the study group and four in the control group. There were no severe complications directly associated with stent implantation or extraction in either of the two groups. CONCLUSION: In this experimental protocol of benign esophageal strictures, the novel "pieced" stent demonstrated a superior removal rate with a similar migration rate compared to a conventional stent.
AIM: To investigate a newly designed stent and its dilatation effect in a rabbit model of benign esophageal stricture. METHODS: Thirty-four New Zealand white rabbits underwent a corrosive injury in the middle esophagus for esophageal stricture formation. Thirty rabbits with a successful formation of esophageal strictures were randomly allocated into two groups. The control group (n = 15) was implanted with a conventional stent, and the study group (n = 15) was implanted with a detachable "pieced" stent. The study stent (30 mm in length, 10 mm in diameter) was composed of three covered metallic pieces connected by surgical suture lines. The stent was collapsed by pulling the suture lines out of the mesh. Two weeks after stricture formation, endoscopic placement of a conventional stent or the new stent was performed. Endoscopic extraction was carried out four weeks later. The extraction rate, ease of extraction, migration, complications, and survival were evaluated. RESULTS: Stent migration occurred in 3/15 (20%) animals in the control group and 2/15 (13%) animals in the study group; the difference between the two groups was not statistically significant. At the end of four weeks, the remaining stents were successfully extracted with the endoscope in 100% (11/11) of the animals in the study group, and 60% (6/10) of the animals in the control group; this difference was statistically significant (P < 0.05). There was no difference in the mean number of follow-up days between the control and study groups (25.33 vs 25.85). Minor bleeding was reported in five cases in the study group and four in the control group. There were no severe complications directly associated with stent implantation or extraction in either of the two groups. CONCLUSION: In this experimental protocol of benign esophageal strictures, the novel "pieced" stent demonstrated a superior removal rate with a similar migration rate compared to a conventional stent.
Authors: Els M L Verschuur; Marjolein Y V Homs; Ewout W Steyerberg; Jelle Haringsma; Peter J Wahab; Ernst J Kuipers; Peter D Siersema Journal: Gastrointest Endosc Date: 2006-01 Impact factor: 9.427
Authors: Adrian N Holm; Jose G de la Mora Levy; Christopher J Gostout; Mark D Topazian; Todd H Baron Journal: Gastrointest Endosc Date: 2007-10-22 Impact factor: 9.427
Authors: Ivana Dzeletovic; David E Fleischer; Michael D Crowell; Rahul Pannala; Lucinda A Harris; Francisco C Ramirez; George E Burdick; Lauri A Rentz; Robert V Spratley; Susan D Helling; Jeffrey A Alexander Journal: Dig Dis Sci Date: 2013-08-08 Impact factor: 3.199
Authors: Els M L Verschuur; Alessandro Repici; Ernst J Kuipers; Ewout W Steyerberg; Peter D Siersema Journal: Am J Gastroenterol Date: 2007-09-25 Impact factor: 10.864