Literature DB >> 18726550

The Bath metrology index as assessed by a trained and an untrained rater in patients with spondylarthropathy: a study of intra- and inter-rater agreements.

O R Madsen1, L B Hansen, A Rytter, C Suetta, C Egsmose.   

Abstract

The Bath ankylosing spondylitis metrology index (BASMI; range 0-10) has gained widespread use in daily clinical practice as an objective measure of spinal stiffness not only in patients with ankylosing spondylitis (AS) but also in patients with other spondylarthropathies (SpA). We examined intra-rater and inter-rater reproducibility of BASMI scoring in 30 Danish patients with SpA (median age 40 years, range 22-56 years) fulfilling the European Spondylarthropathy Study Group criteria, 25 of them satisfying the modified New York Criteria for AS. Measurements were performed twice on two different days (median interval 7 days, range 4-11) by a trained physiotherapist (PT) and by an untrained nurse who had undergone a single 1-h training session with the PT. The median BASMI score obtained by the PT on the two test days was 3.5 (range 1-8) and 3.0 (range 1-8), respectively (NS). Test-retest BASMI scores from the PT were significantly correlated (r(s) = 0.95, p < 0.0001). The 95% likely range for the difference between a patient's BASMI scores from two tests was +/-1.4 corresponding to a minimal detectable difference of +/-2 in the individual patient as the scale consists of intervals of 1. Similar results were achieved by the nurse. BASMI scores obtained by the two raters were significantly inter-correlated (r(s) = 0.95, p < 0.0001). The mean difference between paired BASMI scores obtained by the nurse and the PT on test day 1 was -0.2 with a minimal detectable difference of +/-2. A similar result was found using data from test day 2. In conclusion, a change in BASMI less than 2 may be due solely to expected random measurement error. A single 1-h training session allowed an untrained nurse to obtain BASMI results almost identical to those of an experienced PT.

Entities:  

Mesh:

Year:  2008        PMID: 18726550     DOI: 10.1007/s10067-008-0978-x

Source DB:  PubMed          Journal:  Clin Rheumatol        ISSN: 0770-3198            Impact factor:   2.980


  21 in total

1.  DANBIO: a nationwide registry of biological therapies in Denmark.

Authors:  M L Hetland
Journal:  Clin Exp Rheumatol       Date:  2005 Sep-Oct       Impact factor: 4.473

2.  Measurement error and correlation coefficients.

Authors:  J M Bland; D G Altman
Journal:  BMJ       Date:  1996-07-06

3.  Efficacy and safety of adalimumab in patients with ankylosing spondylitis: results of a multicenter, randomized, double-blind, placebo-controlled trial.

Authors:  Désirée van der Heijde; Alan Kivitz; Michael H Schiff; Joachim Sieper; Ben A C Dijkmans; Jürgen Braun; Maxime Dougados; John D Reveille; Robert L Wong; Hartmut Kupper; John C Davis
Journal:  Arthritis Rheum       Date:  2006-07

4.  The Swedish version of the Bath ankylosing spondylitis functional index. Reliability and validity.

Authors:  H Cronstedt; A Waldner; C H Stenström
Journal:  Scand J Rheumatol Suppl       Date:  1999

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Evaluation of diagnostic criteria for ankylosing spondylitis. A proposal for modification of the New York criteria.

Authors:  S van der Linden; H A Valkenburg; A Cats
Journal:  Arthritis Rheum       Date:  1984-04

7.  The European Spondylarthropathy Study Group preliminary criteria for the classification of spondylarthropathy.

Authors:  M Dougados; S van der Linden; R Juhlin; B Huitfeldt; B Amor; A Calin; A Cats; B Dijkmans; I Olivieri; G Pasero
Journal:  Arthritis Rheum       Date:  1991-10

8.  A new approach to defining functional ability in ankylosing spondylitis: the development of the Bath Ankylosing Spondylitis Functional Index.

Authors:  A Calin; S Garrett; H Whitelock; L G Kennedy; J O'Hea; P Mallorie; T Jenkinson
Journal:  J Rheumatol       Date:  1994-12       Impact factor: 4.666

9.  Proposal of a linear definition of the Bath Ankylosing Spondylitis Metrology Index (BASMI) and comparison with the 2-step and 10-step definitions.

Authors:  D van der Heijde; R Landewé; E Feldtkeller
Journal:  Ann Rheum Dis       Date:  2007-08-29       Impact factor: 19.103

10.  Spinal mobility in ankylosing spondylitis: reliability, validity and responsiveness.

Authors:  K L Haywood; A M Garratt; K Jordan; K Dziedzic; P T Dawes
Journal:  Rheumatology (Oxford)       Date:  2004-04-07       Impact factor: 7.580

View more
  6 in total

1.  Validation of a new objective index to measure spinal mobility: the University of Cordoba Ankylosing Spondylitis Metrology Index (UCOASMI).

Authors:  Juan L Garrido-Castro; Alejandro Escudero; Rafael Medina-Carnicer; Alfonso M Galisteo; Cristina Gonzalez-Navas; Loreto Carmona; Eduardo Collantes-Estevez
Journal:  Rheumatol Int       Date:  2013-12-20       Impact factor: 2.631

2.  Spinal inflammation by magnetic resonance imaging in patients with ankylosing spondylitis: association with disease activity and outcome parameters.

Authors:  Sefika Konca; Dilek Keskin; Deniz Cılız; Hatice Bodur; Bülent Sakman
Journal:  Rheumatol Int       Date:  2011-12-11       Impact factor: 2.631

3.  An exploration of the inter- and intra-rater reliability of the Bath Ankylosing Spondylitis Metrology Index.

Authors:  Jane H Martindale; Chris J Sutton; Lynne Goodacre
Journal:  Clin Rheumatol       Date:  2012-08-15       Impact factor: 2.980

4.  Reproducibility of the Bath Ankylosing Spondylitis Indices of disease activity (BASDAI), functional status (BASFI) and overall well-being (BAS-G) in anti-tumour necrosis factor-treated spondyloarthropathy patients.

Authors:  Ole R Madsen; Anne Rytter; Lonnie B Hansen; Charlotte Suetta; Charlotte Egsmose
Journal:  Clin Rheumatol       Date:  2010-03-21       Impact factor: 2.980

5.  Inter-rater reliability of clinical mobility measures in ankylosing spondylitis.

Authors:  J Calvo-Gutiérrez; J L Garrido-Castro; C González-Navas; M C Castro-Villegas; R Ortega-Castro; C López-Medina; P Font-Ugalde; A Escudero-Contreras; E Collantes-Estévez
Journal:  BMC Musculoskelet Disord       Date:  2016-09-05       Impact factor: 2.362

6.  A Wearable System Based on Multiple Magnetic and Inertial Measurement Units for Spine Mobility Assessment: A Reliability Study for the Evaluation of Ankylosing Spondylitis.

Authors:  Adriana Martínez-Hernández; Juan S Perez-Lomelí; Ruben Burgos-Vargas; Miguel A Padilla-Castañeda
Journal:  Sensors (Basel)       Date:  2022-02-10       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.