Literature DB >> 18724023

Clinical utility of 3-dimensional echocardiography in the evaluation of tricuspid regurgitation caused by pacemaker leads.

Yoshihiro Seo1, Tomoko Ishizu, Hideki Nakajima, Yukio Sekiguchi, Shigeyuki Watanabe, Kazutaka Aonuma.   

Abstract

BACKGROUND: This study evaluated the usefulness of 3-dimensional echocardiography (3-DE) for identifying permanent pacemaker (PPM) or implantable cardioverter defibrillator (ICD) lead-related symptomatic tricuspid regurgitation (TR). METHODS AND
RESULTS: Eighty-seven patients underwent 3-DE examination: 50 patients with PPM, 17 with ICD, and 20 with cardiac resynchronization therapy devices. TR severity was classified as trivial/mild, moderate, or severe according to the ratio of TR area to right atrium area. The 3-DE identified the lead route and position at the tricuspid valve in 82 patients (94.2%). In 5 patients, images without lead-induced artifacts could not be obtained. TR severity was trivial/mild in 50 patients, moderate in 20 patients, and severe in 12 patients. In all patients with trivial/mild TR and all but 1 patient with moderate TR, leads were positioned on the annulus side between leaflets. Lead-induced obstruction to tricuspid valve closing was identified in 1 patient with moderate TR and in 7 of 12 patients with severe TR: 4 patients had septal leaflet obstruction, and 4 had posterior leaflet obstruction.
CONCLUSIONS: The 3-DE can identify the lead route and position at the tricuspid valve and lead-related severe TR, so may be a useful technique of diagnosing the cause of severe TR in patients with PPM or ICD.

Entities:  

Mesh:

Year:  2008        PMID: 18724023     DOI: 10.1253/circj.cj-08-0227

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  17 in total

Review 1.  Evaluation of tricuspid valve morphology and function by transthoracic three-dimensional echocardiography.

Authors:  Denisa Muraru; Luigi P Badano; Cristiano Sarais; Elena Soldà; Sabino Iliceto
Journal:  Curr Cardiol Rep       Date:  2011-06       Impact factor: 2.931

Review 2.  Tricuspid valve incompetence following implantation of ventricular leads.

Authors:  Giselle A Baquero; Jerry Luck; Gerald V Naccarelli; Mario D Gonzalez; Javier E Banchs
Journal:  Curr Heart Fail Rep       Date:  2015-04

3.  The mechanism of endocardial lead-induced tricuspid regurgitation.

Authors:  Espeed Khoshbin; Abdelrahman Abdelbar; Stuart Allen; Ragheb Hasan
Journal:  BMJ Case Rep       Date:  2013-04-09

4.  Impact of implantable transvenous device lead location on severity of tricuspid regurgitation.

Authors:  Karima Addetia; Francesco Maffessanti; Anuj Mediratta; Megan Yamat; Lynn Weinert; Joshua D Moss; Hemal M Nayak; Martin C Burke; Amit R Patel; Eric Kruse; Valluvan Jeevanandam; Victor Mor-Avi; Roberto M Lang
Journal:  J Am Soc Echocardiogr       Date:  2014-08-14       Impact factor: 5.251

5.  Three-dimensional echocardiography in the diagnosis of pacemaker lead perforation.

Authors:  Akinori Sugano; Yoshihiro Seo; Akiko Atsumi; Masayoshi Yamamoto; Tomoko Machino-Ohtuska; Ryo Kawamura; Hideki Nakajima; Tomoko Ishizu; Kazutaka Aonuma
Journal:  J Echocardiogr       Date:  2012-10-01

6.  Massive tricuspid regurgitation due to pacemaker-lead puncture of the tricuspid valve: successful diagnosis by 3-dimensional echocardiography.

Authors:  Rina Tamai; Tomoya Hara; Hirotsugu Yamada; Susumu Nishio; Mika Bando; Junko Hotchi; Shuji Hayashi; Toshiyuki Niki; Tetsuya Kitagawa; Masataka Sata
Journal:  J Med Ultrason (2001)       Date:  2013-05-31       Impact factor: 1.314

7.  Pacing lead extraction in the management of tricuspid regurgitation: a case report.

Authors:  Lynn Khor; Kedar Madan; Choon Huat Lee; Martin K C Ng
Journal:  Eur Heart J Case Rep       Date:  2022-05-17

8.  Tricuspid stenosis: An emerging disease in cardiac implantable electronic devices era. Case report and literature review.

Authors:  Aysha Husain; Faris Tufail Raja; Ahmed Fatallah; Bahaa Fadel; Aly Alsanei; Fahad Tufail Raja; Bandar AlGhamdi
Journal:  J Cardiol Cases       Date:  2017-04-14

Review 9.  Echocardiography in Infective Endocarditis: State of the Art.

Authors:  Luis Afonso; Anupama Kottam; Vivek Reddy; Anirudh Penumetcha
Journal:  Curr Cardiol Rep       Date:  2017-10-25       Impact factor: 2.931

Review 10.  Tricuspid regurgitation following implantation of a pacemaker/cardioverter-defibrillator.

Authors:  Maha A Al-Mohaissen; Kwan Leung Chan
Journal:  Curr Cardiol Rep       Date:  2013-05       Impact factor: 2.931

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.