Literature DB >> 18721709

Comparison of anterior capsule contraction between 5 foldable intraocular lens models.

Mayumi Nagata1, Hiroyuki Matsushima, Koichiro Mukai, Wataru Terauchi, Norihito Gotoh, Eichiro Matsui.   

Abstract

PURPOSE: To compare anterior capsule contraction in cataract patients having implantation of 1 of 5 foldable intraocular lens (IOL) models and evaluate lens epithelial cell (LEC) adhesion to each model.
SETTING: Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan.
METHODS: This study comprised 115 patients (126 eyes) without systemic or ocular complications who had phacoemulsification with IOL implantation. The eyes were randomly assigned to receive 1 of the following IOLs: acrylic MA60BM (Alcon), SA60AT (Alcon), AR40e (Advanced Medical Optics), or YA-60BBR (Hoya) or a silicone AQ310NV (Canon). Two weeks and 1, 3, and 6 months postoperatively, the anterior capsule opening area was measured using an anterior segment analysis system (EAS-1000, Nidek) and the percentage of anterior capsule contraction was compared for each postoperative period and IOL. Cell adhesion to each IOL type was evaluated using LECs from albino rabbits.
RESULTS: The mean age of the patients was 73.6 years +/- 5.6 (SD). Eyes with the AQ310NV and AR40e IOLs had statistically significantly greater anterior capsule contraction. The rabbit study showed statistically significantly less LEC adhesion on these 2 IOL models.
CONCLUSIONS: Anterior capsule contraction was significantly greater with the AQ310NV and AR40e IOLs than with the other IOLs. Results indicate that cell adhesion to the IOL is an important factor in preventing anterior capsule contraction.

Entities:  

Mesh:

Year:  2008        PMID: 18721709     DOI: 10.1016/j.jcrs.2008.04.039

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  4 in total

1.  [Evaluation of methodological quality in published RCTs on cataract surgery : Pilot study on the degree of adherence to CONSORT statement requirements and their qualitative validity].

Authors:  C Baulig; F Krummenauer; S Knippschild
Journal:  Ophthalmologe       Date:  2018-01       Impact factor: 1.059

2.  Femtosecond laser assisted capsulotomy in the treatment of capsule contraction case report.

Authors:  Pablo Larco Recalde; Carolina Larco; Daniel Torres; Pablo Larco
Journal:  Am J Ophthalmol Case Rep       Date:  2020-08-23

Review 3.  Biomaterial Influence on Intraocular Lens Performance: An Overview.

Authors:  Cari Pérez-Vives
Journal:  J Ophthalmol       Date:  2018-03-15       Impact factor: 1.909

4.  Comparison Study of Anterior Capsule Contraction of Hydrophilic and Hydrophobic Intraocular Lenses Under the Same Size Capsulotomy.

Authors:  Yuyan Wang; Wei Wang; Yanan Zhu; Jia Xu; Chenqi Luo; Ke Yao
Journal:  Transl Vis Sci Technol       Date:  2022-01-03       Impact factor: 3.283

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.