Literature DB >> 18721705

Microincision multifocal intraocular lens with and without a capsular tension ring: optical quality and clinical outcomes.

Jorge L Alió1, Bassam Elkady, Dolores Ortiz, Gonzalo Bernabeu.   

Abstract

PURPOSE: To study the effect of a capsular tension ring (CTR) on the visual, refractive, and intraocular optical quality of a multifocal intraocular lens (IOL) with diffractive asymmetrical light distribution.
SETTING: Vissum-Instituto de Oftalmológico de Alicante, Alicante, Spain.
METHODS: An Acri.Lisa 366D IOL was implanted without CTR implantation in 54 eyes (Group 1) or with Acri. Ring BR 11 CTR implantation in 40 eyes (Group 2). Intraocular optical quality in vivo was characterized by the difference between the postoperative total and corneal optical aberrations. Visual, refractive, and intraocular optical outcomes were evaluated 3 months postoperatively. Main outcome measures included postoperative residual refraction, uncorrected and corrected far and near visual acuities, intraocular aberrations, the Strehl ratio, and the modulation transfer function (MTF).
RESULTS: The postoperative means in Group 1 were spherical equivalent, 0.31 +/- 0.45 diopters (D); uncorrected distance acuity, 0.79 +/- 0.19; best corrected distance acuity, 0.95 +/- 0.11; uncorrected near acuity, 0.77 +/- 0.21; best corrected near acuity, 0.89 +/- 0.14; best distance-corrected acuity, 0.90 +/- 0.12. The Group 2 means were -0.18 +/- 0.60 D, 0.74 +/- 0.23, 0.98 +/- 0.07, 0.72 +/- 0.22, 0.86 +/- 0.14, and 0.86 +/- 0.14, respectively. Group 2 had a statistically significant reduction in intraocular aberrations and a significant increase in MTF values and Strehl ratios compared with Group 1.
CONCLUSION: Combined use of the CTR and Acri.Lisa 366D IOL provided good efficacy, predictability, and safety and increased the intraocular optical performance, suggesting better IOL stability.

Entities:  

Mesh:

Year:  2008        PMID: 18721705     DOI: 10.1016/j.jcrs.2008.05.042

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  6 in total

1.  Effect of capsular tension ring implantation on predicted refractive error after cataract surgery in patients with pseudoexfoliation syndrome.

Authors:  Mohammad Malekahmadi; Sadegh Kazemi; Farideh Sharifipour; Farshad Ostadian; Atefeh Mahdian Rad; Mohammad Sadegh Mirdehghan
Journal:  Int J Ophthalmol       Date:  2020-04-18       Impact factor: 1.779

2.  Effect of Co-Implantation of a Capsular Tension Ring on Clinical Outcomes after Cataract Surgery with Monofocal Intraocular Lens Implantation.

Authors:  Hyun Ju Park; Hun Lee; Do Wook Kim; Eung Kweon Kim; Kyoung Yul Seo; Tae Im Kim
Journal:  Yonsei Med J       Date:  2016-09       Impact factor: 2.759

3.  Effect of capsular tension ring implantation on capsular stability after phacoemulsification in patients with weak zonules: a randomized controlled trial. CTR implantation in cataract patients with weak zonules.

Authors:  Shangfei Yang; Hui Jiang; Kailai Nie; Liwen Feng; Wei Fan
Journal:  BMC Ophthalmol       Date:  2021-01-07       Impact factor: 2.209

4.  How to Manage the Cortex After CTR Insertion.

Authors:  Kazuki Matsuura; Teruyuki Miyoshi; Hironori Yoshida; Takahiro Shimowake
Journal:  Clin Ophthalmol       Date:  2022-04-08

5.  Clinical outcomes with a new microincisional diffractive multifocal IOL.

Authors:  Jorge L Alió; Alfredo Vega-Estrada; Ana B Plaza-Puche
Journal:  Eye Vis (Lond)       Date:  2015-01-31

6.  Effects of capsular tension ring on surgical outcomes of premium intraocular lens in patients with suspected zonular weakness.

Authors:  Teruyuki Miyoshi; Shuhei Fujie; Hironori Yoshida; Hiroshi Iwamoto; Hideki Tsukamoto; Tetsuro Oshika
Journal:  PLoS One       Date:  2020-02-24       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.