Literature DB >> 18718398

Policy of routine titanium miniplate removal after maxillofacial trauma.

Hanna Thorén1, Johanna Snäll, Wock Hallermann, Eeva Kormi, Jyrki Törnwall.   

Abstract

PURPOSE: The literature shows that hardware removal rates after the fixation of maxillofacial fractures with miniplates are not insignificant. The aim of the present survey was to clarify the policies of Finnish oral and maxillofacial consultants for the removal of titanium miniplates after the treatment of facial fractures in adults. Additional aims were to clarify the factors influencing plate removal policy in general, and the reasons for routine plate removal in particular.
MATERIALS AND METHODS: Twenty-six consultant oral and maxillofacial surgeons responded to a questionnaire about miniplate removal policy after treating 5 types of simple, noncomminuted fractures.
RESULTS: Overall, routine plate removal was uncommon. However, 12 consultants (46.2%) routinely removed the plate after treating mandibular angle fractures, and simultaneously extracted the third molar because of an increased risk of infection. Most respondents (88.5%) stated that clinical experience guided their plate-removal policy. A policy of routine plate removal was most infrequent among the consultants who had the most experience.
CONCLUSIONS: The literature provides no definitive answer to the question of whether routine removal of miniplates could or should be indicated, and in what situations. Considering the fairly significant frequency of plate-related complications in general and infection-related complications in particular, long-term follow-up after treatment is indicated.

Entities:  

Mesh:

Year:  2008        PMID: 18718398     DOI: 10.1016/j.joms.2008.03.009

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  4 in total

1.  Titanium osteosynthesis hardware in maxillofacial trauma surgery: to remove or remain? A retrospective study.

Authors:  Z Pan; P M Patil
Journal:  Eur J Trauma Emerg Surg       Date:  2013-11-19       Impact factor: 3.693

2.  Locoregional anesthesia for removal osteosynthesis hardware from healed corpus mandibularis fractures: A descriptive study of a series of 40 cases.

Authors:  Rachid Aloua; Ouassime Kerdoud; Amine Kaouani; Ousmane Belem; Tarcissus Konsem; Faiçal Slimani
Journal:  Ann Med Surg (Lond)       Date:  2021-07-27

3.  Routine removal of the plate after surgical treatment for mandibular angle fracture with a third molar in relation to the fracture line.

Authors:  Kazuhiko Yamamoto; Yumiko Matsusue; Satoshi Horita; Kazuhiro Murakami; Tsutomu Sugiura; Tadaaki Kirita
Journal:  Ann Maxillofac Surg       Date:  2015 Jan-Jun

4.  Is Mini-Plate Removal Necessary for Oral and Maxillofacial Surgery Patients? A Five-Year Case-Control Study.

Authors:  Mehdi Fani; Sahand Samieirad; Zahra Shooshtari; Maryam Jamali; Elahe Tohidi
Journal:  Front Dent       Date:  2020-04-07
  4 in total