Variables that affect platelet function analyzer-100 (PFA-100) closure times and establishment of reference intervals in Korean adults.

Young-Uk Cho1, Seongsoo Jang, Chan-Jeoung Park, Hyun-Sook Chi.   

Abstract

The PFA-100 is an in vitro system for measurement of platelet function in whole blood. To establish reference intervals in the Korean population, we investigated the relationships between PFA-100 closure times and gender, ABO blood group, citrate concentration, and time of blood collection in 120 well-characterized healthy Korean adults. Gender did not affect closure time values. Blood group O was associated with longer collagen/epinephrine (CEPI) and collagen/ADP (CADP) closure times than non-O groups (p <0.0001 for both). Closure times were shorter in samples obtained in the morning vs the afternoon. Regression analysis showed an association between CEPI and CADP closure times (p <0.0001), but there were no associations between PFA-100 results and WBC count, hemoglobin, hematocrit, platelet count, and platelet-associated parameters. The reference intervals for CEPI and CADP closure times of 3.2% citrated blood were 80-162 and 64-121 sec, respectively. The reference intervals for PFA-100 closure times in healthy Korean adults were similar to those in Western populations. Flow obstruction was observed in 31 of 480 (6.5%) measurements, but routine performance of duplicate measurements was otherwise unnecessary because of acceptable CV values. PFA-100 closure time should be interpreted with consideration of the patient's clinical presentation and factors such as ABO blood group and diurnal variation.

Entities:  

Mesh:

Year:  2008        PMID: 18715853

Source DB:  PubMed          Journal:  Ann Clin Lab Sci        ISSN: 0091-7370            Impact factor:   1.256


  6 in total

1.  Acute effects of 30 minutes of exposure to a smartphone call on in vitro platelet function.

Authors:  Giuseppe Lippi; Elisa Danese; Giorgio Brocco; Matteo Gelati; Gian Luca Salvagno; Martina Montagnana
Journal:  Blood Transfus       Date:  2017-05-06       Impact factor: 3.443

Review 2.  The genetics of common variation affecting platelet development, function and pharmaceutical targeting.

Authors:  A D Johnson
Journal:  J Thromb Haemost       Date:  2011-07       Impact factor: 5.824

3.  Variables that Influence Platelet Function Analyzer-100™ Closure Times in Healthy Algerian Adults.

Authors:  Malika Belkacemi; Yassine Merad
Journal:  Int J Appl Basic Med Res       Date:  2021-07-19

4.  The role of platelet function analyzer-200 in predicting perioperative bleeding risk.

Authors:  Eun Sang Yu; Min Ji Jeon; Ka-Won Kang; Byung-Hyun Lee; Eun Joo Kang; Yong Park; Se Ryeon Lee; Hwa Jung Sung; Chul Won Choi; Byung Soo Kim; Dae Sik Kim
Journal:  Korean J Intern Med       Date:  2020-02-06       Impact factor: 2.884

5.  Establishment of reference intervals for Platelet Function Analyzer -100 closure time in Algerian adults.

Authors:  Malika Belkacemi; Yassine Merad; Mohamed Amine Merbouh
Journal:  PLoS One       Date:  2021-04-12       Impact factor: 3.240

6.  Primary hemostasis in fetal growth restricted neonates studied via PFA-100 in cord blood samples.

Authors:  Maria Kollia; Nicoletta Iacovidou; Zoi Iliodromiti; Abraham Pouliakis; Rozeta Sokou; Vasiliki Mougiou; Maria Boutsikou; Marianna Politou; Theodora Boutsikou; Serena Valsami
Journal:  Front Pediatr       Date:  2022-09-08       Impact factor: 3.569

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.