Literature DB >> 18713694

Preliminary feasibility study of an in-line phase contrast X-ray imaging prototype.

Da Zhang1, Molly Donovan, Laurie L Fajardo, Ann Archer, Xizeng Wu, Hong Liu.   

Abstract

In this study, a series of imaging experiments on biological specimens, including human breast core biopsies, lumpectomy, and chicken tissues, as well as standard phantoms, were performed in an effort to investigate the feasibility of an in-line phase contrast X-ray imaging prototype. The prototype system employed in the study consists of a microfocus X-ray source with tungsten target and a digital flat panel detector, and it can be operated in both conventional attenuation-based imaging mode and in-line phase contrast imaging mode. Biological specimens were imaged in the conventional mode and phase contrast mode with the same source-to-image-detector distance (SID), and phase contrast images exhibited both improved image quality compared with conventional images, and the overshooting patterns along the boundaries in the specimens, which revealed the occurrence of the edge enhancement effect provided by the phase contrast technique. In addition, the performance of the phase contrast mode and conventional mode was compared based on the American College of Radiology (ACR) phantom imaging and contrast detail mammography (CDMAM) phantom-based contrast detail analysis with two experimental settings: one with the same SID and the other with the same object entrance exposure. In both pairs of comparison under our experimental conditions, the phase contrast imaging mode exhibited improved image quality as compared to the conventional mode, which further supported the feasibility of the prototype.

Entities:  

Mesh:

Year:  2008        PMID: 18713694     DOI: 10.1109/TBME.2008.919136

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  19 in total

1.  Small-angle scattering computed tomography (SAS-CT) using a Talbot-Lau interferometerand a rotating anode x-ray tube:theory and experiments.

Authors:  Guang-Hong Chen; Nicholas Bevins; Joseph Zambelli; Zhihua Qi
Journal:  Opt Express       Date:  2010-06-07       Impact factor: 3.894

2.  Performance analysis of the attenuation-partition based iterative phase retrieval algorithm for in-line phase-contrast imaging.

Authors:  Aimin Yan; Xizeng Wu; Hong Liu
Journal:  Opt Express       Date:  2010-07-19       Impact factor: 3.894

3.  A robust general phase retrieval method for medical applications.

Authors:  A Yan; X Wu; H Liu
Journal:  J Instrum       Date:  2013-05-24       Impact factor: 1.415

4.  Characterization of Continuous and Pulsed Emission modes of a Hybrid Micro Focus X-ray Source for Medical Imaging Applications.

Authors:  Muhammad U Ghani; Molly D Wong; Liqiang Ren; Di Wu; Bin Zheng; John X Rong; Xizeng Wu; Hong Liu
Journal:  Nucl Instrum Methods Phys Res A       Date:  2017-02-16       Impact factor: 1.455

5.  Characterization of a high-energy in-line phase contrast tomosynthesis prototype.

Authors:  Di Wu; Aimin Yan; Yuhua Li; Molly D Wong; Bin Zheng; Xizeng Wu; Hong Liu
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

6.  Phantom-based comparison of conventional versus phase-contrast mammography for LCD soft-copy diagnosis.

Authors:  Akiko Ihori; Naotoshi Fujita; Akihiro Sugiura; Naruomi Yasuda; Yoshie Kodera
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-12-23       Impact factor: 2.924

7.  Low dose high energy x-ray in-line phase sensitive imaging prototype: Investigation of optimal geometric conditions and design parameters.

Authors:  Muhammad U Ghani; Aimin Yan; Molly D Wong; Yuhua Li; Liqiang Ren; Xizeng Wu; Hong Liu
Journal:  J Xray Sci Technol       Date:  2015       Impact factor: 1.535

8.  Feasibility testing of a pre-clinical coded aperture phase contrast imaging configuration using a simple fast Monte Carlo simulator.

Authors:  Anthony Kavanagh; Alessandro Olivo; Robert Speller; Borivoj Vojnovic
Journal:  Biomed Opt Express       Date:  2013-12-04       Impact factor: 3.732

9.  Dose and detectability improvements with high energy phase sensitive x-ray imaging in comparison to low energy conventional imaging.

Authors:  Molly Donovan Wong; Aimin Yan; Muhammad Ghani; Yuhua Li; Laurie Fajardo; Xizeng Wu; Hong Liu
Journal:  Phys Med Biol       Date:  2014-04-15       Impact factor: 3.609

10.  Image quality and dose efficiency of high energy phase sensitive x-ray imaging: phantom studies.

Authors:  Molly Donovan Wong; Xizeng Wu; Hong Liu
Journal:  J Xray Sci Technol       Date:  2014       Impact factor: 1.535

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.