A technique for generating phase-space-based Monte Carlo beamlets in radiotherapy applications.

K Bush1, I A Popescu, S Zavgorodni.   

Abstract

As radiotherapy treatment planning moves toward Monte Carlo (MC) based dose calculation methods, the MC beamlet is becoming an increasingly common optimization entity. At present, methods used to produce MC beamlets have utilized a particle source model (PSM) approach. In this work we outline the implementation of a phase-space-based approach to MC beamlet generation that is expected to provide greater accuracy in beamlet dose distributions. In this approach a standard BEAMnrc phase space is sorted and divided into beamlets with particles labeled using the inheritable particle history variable. This is achieved with the use of an efficient sorting algorithm, capable of sorting a phase space of any size into the required number of beamlets in only two passes. Sorting a phase space of five million particles can be achieved in less than 8 s on a single-core 2.2 GHz CPU. The beamlets can then be transported separately into a patient CT dataset, producing separate dose distributions (doselets). Methods for doselet normalization and conversion of dose to absolute units of Gy for use in intensity modulated radiation therapy (IMRT) plan optimization are also described.

Entities:  

Mesh:

Year:  2008        PMID: 18711246     DOI: 10.1088/0031-9155/53/18/N01

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Design and development of a new micro-beam treatment planning system: effectiveness of algorithms of optimization and dose calculations and potential of micro-beam treatment.

Authors:  Hidenobu Tachibana; Hiroyuki Kojima; Noritaka Yusa; Satoshi Miyajima; Akihisa Tsuda; Takashi Yamashita
Journal:  Radiol Phys Technol       Date:  2012-04-29

2.  Generation of a novel phase-space-based cylindrical dose kernel for IMRT optimization.

Authors:  Hualiang Zhong; Indrin J Chetty
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

Review 3.  Monte Carlo systems used for treatment planning and dose verification.

Authors:  Lorenzo Brualla; Miguel Rodriguez; Antonio M Lallena
Journal:  Strahlenther Onkol       Date:  2016-11-25       Impact factor: 3.621

4.  Full Monte Carlo-Based Biologic Treatment Plan Optimization System for Intensity Modulated Carbon Ion Therapy on Graphics Processing Unit.

Authors:  Nan Qin; Chenyang Shen; Min-Yu Tsai; Marco Pinto; Zhen Tian; Georgios Dedes; Arnold Pompos; Steve B Jiang; Katia Parodi; Xun Jia
Journal:  Int J Radiat Oncol Biol Phys       Date:  2017-09-12       Impact factor: 7.038

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.