Literature DB >> 18697528

A feasibility study to calculate unshielded fetal doses to pregnant patients in 6-MV photon treatments using Monte Carlo methods and anatomically realistic phantoms.

Bryan Bednarz1, X George Xu.   

Abstract

A Monte Carlo-based procedure to assess fetal doses from 6-MV external photon beam radiation treatments has been developed to improve upon existing techniques that are based on AAPM Task Group Report 36 published in 1995 [M. Stovall et al., Med. Phys. 22, 63-82 (1995)]. Anatomically realistic models of the pregnant patient representing 3-, 6-, and 9-month gestational stages were implemented into the MCNPX code together with a detailed accelerator model that is capable of simulating scattered and leakage radiation from the accelerator head. Absorbed doses to the fetus were calculated for six different treatment plans for sites above the fetus and one treatment plan for fibrosarcoma in the knee. For treatment plans above the fetus, the fetal doses tended to increase with increasing stage of gestation. This was due to the decrease in distance between the fetal body and field edge with increasing stage of gestation. For the treatment field below the fetus, the absorbed doses tended to decrease with increasing gestational stage of the pregnant patient, due to the increasing size of the fetus and relative constant distance between the field edge and fetal body for each stage. The absorbed doses to the fetus for all treatment plans ranged from a maximum of 30.9 cGy to the 9-month fetus to 1.53 cGy to the 3-month fetus. The study demonstrates the feasibility to accurately determine the absorbed organ doses in the mother and fetus as part of the treatment planning and eventually in risk management.

Entities:  

Mesh:

Year:  2008        PMID: 18697528      PMCID: PMC2809713          DOI: 10.1118/1.2938519

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  30 in total

1.  A reduction in the AAPM TG-36 reported peripheral dose distributions with tertiary multileaf collimation. American Association of Physicists in Medicine Task Group 36.

Authors:  S Mutic; E E Klein
Journal:  Int J Radiat Oncol Biol Phys       Date:  1999-07-01       Impact factor: 7.038

2.  Comparisons between MCNP, EGS4 and experiment for clinical electron beams.

Authors:  R Jeraj; P J Keall; P M Ostwald
Journal:  Phys Med Biol       Date:  1999-03       Impact factor: 3.609

3.  Neutron fluence and energy spectra around the Varian Clinac 2100C/2300C medical accelerator.

Authors:  K R Kase; X S Mao; W R Nelson; J C Liu; J H Kleck; M Elsalim
Journal:  Health Phys       Date:  1998-01       Impact factor: 1.316

4.  The calculated risk of fatal secondary malignancies from intensity-modulated radiation therapy.

Authors:  Stephen F Kry; Mohammad Salehpour; David S Followill; Marilyn Stovall; Deborah A Kuban; R Allen White; Isaac I Rosen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-07-15       Impact factor: 7.038

5.  Brain radiotherapy during pregnancy: an analysis of conceptus dose using anthropomorphic phantoms.

Authors:  M Mazonakis; J Damilakis; N Theoharopoulos; H Varveris; N Gourtsoyiannis
Journal:  Br J Radiol       Date:  1999-03       Impact factor: 3.039

Review 6.  Fetal dose from radiotherapy with photon beams: report of AAPM Radiation Therapy Committee Task Group No. 36.

Authors:  M Stovall; C R Blackwell; J Cundiff; D H Novack; J R Palta; L K Wagner; E W Webster; R J Shalek
Journal:  Med Phys       Date:  1995-01       Impact factor: 4.071

7.  Estimates of whole-body dose equivalent produced by beam intensity modulated conformal therapy.

Authors:  D Followill; P Geis; A Boyer
Journal:  Int J Radiat Oncol Biol Phys       Date:  1997-06-01       Impact factor: 7.038

8.  Fetal dose evaluation during breast cancer radiotherapy.

Authors:  C Antypas; P Sandilos; J Kouvaris; E Balafouta; E Karinou; N Kollaros; L Vlahos
Journal:  Int J Radiat Oncol Biol Phys       Date:  1998-03-01       Impact factor: 7.038

9.  Specific absorbed fractions for internal photon emitters calculated for a tomographic model of a pregnant woman.

Authors:  C Y Shi; X G Xu; M G Stabin
Journal:  Health Phys       Date:  2004-11       Impact factor: 1.316

10.  Fetal dose estimates for electron-beam treatment to the chest wall of a pregnant patient.

Authors:  J A Antolak; E A Strom
Journal:  Med Phys       Date:  1998-12       Impact factor: 4.071

View more
  13 in total

1.  Estimation of organs doses and radiation-induced secondary cancer risk from scattered photons for conventional radiation therapy of nasopharynx: a Monte Carlo study.

Authors:  Asghar Mesbahi; Farshad Seyednejad; Amir Gasemi-Jangjoo
Journal:  Jpn J Radiol       Date:  2010-06-30       Impact factor: 2.374

2.  Therapeutic combination of radiolabeled CLR1404 with external beam radiation in head and neck cancer model systems.

Authors:  Zachary S Morris; Jamey P Weichert; Jarob Saker; Eric A Armstrong; Abigail Besemer; Bryan Bednarz; Randall J Kimple; Paul M Harari
Journal:  Radiother Oncol       Date:  2015-06-26       Impact factor: 6.280

3.  Reconstruction of organ dose for external radiotherapy patients in retrospective epidemiologic studies.

Authors:  Choonik Lee; Jae Won Jung; Christopher Pelletier; Anil Pyakuryal; Stephanie Lamart; Jong Oh Kim; Choonsik Lee
Journal:  Phys Med Biol       Date:  2015-02-26       Impact factor: 3.609

4.  Analytical model for out-of-field dose in photon craniospinal irradiation.

Authors:  Phillip J Taddei; Wassim Jalbout; Rebecca M Howell; Nabil Khater; Fady Geara; Kenneth Homann; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2013-10-08       Impact factor: 3.609

5.  Monte Carlo modeling of a 6 and 18 MV Varian Clinac medical accelerator for in-field and out-of-field dose calculations: development and validation.

Authors:  Bryan Bednarz; X George Xu
Journal:  Phys Med Biol       Date:  2009-01-14       Impact factor: 3.609

6.  A study of the shielding used to reduce leakage and scattered radiation to the fetus in a pregnant patient treated with a 6-MV external X-ray beam.

Authors:  Bin Han; Bryan Bednarz; X George Xu
Journal:  Health Phys       Date:  2009-12       Impact factor: 1.316

Review 7.  A review of dosimetry studies on external-beam radiation treatment with respect to second cancer induction.

Authors:  X George Xu; Bryan Bednarz; Harald Paganetti
Journal:  Phys Med Biol       Date:  2008-06-09       Impact factor: 3.609

8.  A Novel Method to Extend a Partial-Body CT for the Reconstruction of Dose to Organs beyond the Scan Range.

Authors:  Gleb A Kuzmin; Matthew M Mille; Jae Won Jung; Choonik Lee; Christopher Pelletier; Gamal Akabani; Choonsik Lee
Journal:  Radiat Res       Date:  2018-04-04       Impact factor: 2.841

9.  Electron Beam Intraoperative Radiotherapy (ELIOT) in Pregnant Women with Breast Cancer: From in Vivo Dosimetry to Clinical Practice.

Authors:  Maria Leonardi; Agnese Cecconi; Rosa Luraschi; Elena Rondi; Federica Cattani; Roberta Lazzari; Anna Morra; Santos Soto; Vanna Zanagnolo; Viviana Galimberti; Oreste Gentilini; Fedro Peccatori; Barbara Jereczek-Fossa; Roberto Orecchia
Journal:  Breast Care (Basel)       Date:  2017-12-13       Impact factor: 2.860

10.  Monte Carlo Study of Fetal Dosimetry Parameters for 6 MV Photon Beam.

Authors:  Maryam Atarod; Parvaneh Shokrani
Journal:  J Med Signals Sens       Date:  2013-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.