Effect of dose metrics and radiation risk models when optimizing CT x-ray tube voltage.

W Huda1, K M Ogden, M R Khorasani.   

Abstract

We investigated the effect of different CT dose metrics, as well as the implications of various radiation risk models, on the optimization of x-ray tube voltage (kV) in CT. Soft tissue attenuation characteristics and noise levels, obtained from CT scans of a Rando phantom, were used to compute contrast-to-noise ratios (CNR) at x-ray tube voltages between 80 and 140 kV. Four CT dose metrics were evaluated: (a) CTDIair, (b) weighted CTDIw, (c) organ dose (Dorgan), and (d) effective dose (E). All doses were obtained using the ImPACT CT Dosimetry software package. Soft tissue CNR was adjusted by the modification of the mAs by assuming that CNR(2) was proportional to mAs. Optimization criteria were: (a) maintaining a constant CNR at each kV and identifying the value that minimizes patient dose; and (b) maintaining a constant dose at each kV and identifying the value that maximizes CNR. We also investigated the implication for optimization strategies assuming that radiation risk is proportional to En, with n varying between 0 and 2. Optimizing with respect to phantom measurements (i.e., CTDIair and CTDIw) could generate results that differed quantitatively and qualitatively from those obtained using patient doses (i.e., Dorgan and E). For head CT scans, 140 kV offered the lowest patient doses as well as the highest CNR, whereas in abdominal scans 80 kV was optimal. Use of an optimal kV for CT imaging over current practice of using 120 kV might reduce patient doses by 10-15%, or improve CNR by 5-10%. Assuming that the risk was proportional to En made no difference to the optimal kV for positive values of n up to 2. We conclude that (a) CT optimization with respect to kV should generally be performed with respect to the patient effective dose, (b) neither CTDIair nor the body CTDIw are appropriate for use in CT optimization, (c) the range of current radiation risk models should not affect the optimal kV value in CT imaging.

Entities:  

Mesh:

Year:  2008        PMID: 18695298     DOI: 10.1088/0031-9155/53/17/017

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Quantitative assessment on coronary computed tomography angiography (CCTA) image quality: comparisons between genders and different tube voltage settings.

Authors:  Teo Chee Chian; Norziana Mat Nassir; Mohd Izuan Ibrahim; Ahmad Khairuddin Md Yusof; Akmal Sabarudin
Journal:  Quant Imaging Med Surg       Date:  2017-02

2.  Developing patient-specific dose protocols for a CT scanner and exam using diagnostic reference levels.

Authors:  Keith J Strauss
Journal:  Pediatr Radiol       Date:  2014-07-19

3.  Utility of additional CT examinations driven by completion of a standard trauma imaging protocol in patients transferred for minor trauma.

Authors:  Matthew T Heller; Emanuel Kanal; Omar Almusa; Samuel Schwarz; Marios Papachristou; Rajiv Shah; Stephen Ventrelli
Journal:  Emerg Radiol       Date:  2014-02-16
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.