Quality assurance in stereotactic radiosurgery using a standard linear accelerator.

J S Tsai1, B A Buck, G K Svensson, E Alexander, C W Cheng, E G Mannarino, J S Loeffler.   

Abstract

Methods have recently been developed for using standard linear accelerators to perform stereotactic radiosurgery. The accuracy necessary to perform this procedure requires an intensive quality assurance program to encompass all aspects of dose calibration and mechanical integrity of the treatment unit, the treatment planning process, and treatment delivery. The programs developed at the Joint Center for Radiation Therapy (JCRT) include testing of the linear accelerator and the stereotactic system, cross checking of the treatment planning process, and a quality assurance check list of the treatment delivery procedure. This report outlines in detail the quality assurance program currently in use at the JCRT.

Mesh:

Year:  1991        PMID: 1869467     DOI: 10.1016/0360-3016(91)90694-y

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  6 in total

1.  Head to head comparison of two commercial phantoms used for SRS QA.

Authors:  Vikren Sarkar; Long Huang; Yu-Huei Jessica Huang; Martin W Szegedi; Prema Rassiah-Szegedi; Hui Zhao; Bill J Salter
Journal:  J Radiosurg SBRT       Date:  2016

2.  Glioblastoma revisited: do clinical observations match basic science theory? Radiosurgery: clinical observations.

Authors:  E Alexander
Journal:  J Neurooncol       Date:  1993-08       Impact factor: 4.130

3.  Halo ring supporting the Brown-Roberts-Wells stereotactic frame for fractionated radiotherapy.

Authors:  S Carini; G Scielzo; F Grillo Ruggieri; F Bistolfi; M Ravegnani; L Andreussi
Journal:  Acta Neurochir (Wien)       Date:  1994       Impact factor: 2.216

4.  American College of Radiology (ACR) and American Society for Radiation Oncology (ASTRO) Practice Guideline for the Performance of Stereotactic Radiosurgery (SRS).

Authors:  Steven K Seung; David A Larson; James M Galvin; Minesh P Mehta; Louis Potters; Christopher J Schultz; Santosh V Yajnik; Alan C Hartford; Seth A Rosenthal
Journal:  Am J Clin Oncol       Date:  2013-06       Impact factor: 2.339

5.  On the selection of gantry and collimator angles for isocenter localization using Winston-Lutz tests.

Authors:  Weiliang Du; Jennifer L Johnson; Wei Jiang; Rajat J Kudchadker
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

6.  Knowledge-based planning in robotic intracranial stereotactic radiosurgery treatments.

Authors:  Suhong Yu; Huijun Xu; Yin Zhang; Xin Zhang; Michael A Dyer; Ariel E Hirsch; Minh Tam Truong; Heming Zhen
Journal:  J Appl Clin Med Phys       Date:  2021-02-09       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.