Literature DB >> 18694637

Comparison of exhaled nitric oxide measurements between NIOX MINO electrochemical and Ecomedics chemiluminescence analyzer.

J D Boot1, L de Ridder, M L de Kam, C Calderon, M A Mascelli, Z Diamant.   

Abstract

BACKGROUND: Exhaled nitric oxide (eNO) is an established, noninvasive biomarker of active airway inflammation in (atopic) asthma. Treatment with anti-inflammatory therapy, such as inhaled corticosteroids, effectively decreases eNO levels. The NIOX MINO (MINO) is a hand-held, relatively inexpensive, electrochemical device that has been shown to yield comparable eNO measurements to the NIOX stationary unit. AIM: To compare measurements of MINO with another widely used and validated stationary chemiluminescence analyzer, the Ecomedics (ECO).
METHODS: We performed subsequent eNO measurements on ECO and MINO in 50 subjects (19 healthy volunteers, 18 healthy smokers and 13 non-smoking, atopic asthmatics, not on controller therapy) on two visits 4-10 days apart. The mean of three acceptable measurements by ECO and the first acceptable measurement with the MINO were used for analysis.
RESULTS: Both devices yielded reproducible eNO values for all subjects on both visits, with an overall CV of 22.7% (ECO) and 18.3% (MINO). A significant correlation was found between both devices (r=0.97, p<0.0001). Bland-Altman plots showed a high degree of agreement for the entire study population (mean difference MINO vs ECO=-10%; 95% limit of agreement were -36% and +28%) and in the three individual subgroups.
CONCLUSIONS: Exhaled NO values measured with the MINO are reproducible and in agreement with the ECO. Our results add further evidence to the reliability of the MINO and warrant its applicability in research and clinical practice.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18694637     DOI: 10.1016/j.rmed.2008.06.021

Source DB:  PubMed          Journal:  Respir Med        ISSN: 0954-6111            Impact factor:   3.415


  9 in total

1.  Measurement of Fractional Exhaled Nitric Oxide: Comparison of Three Different Analysers.

Authors:  Stephanie Korn; Maike Wilk; Stefanie Voigt; Stephan Weber; Thomas Keller; Roland Buhl
Journal:  Respiration       Date:  2019-07-09       Impact factor: 3.580

Review 2.  Noninvasive effects measurements for air pollution human studies: methods, analysis, and implications.

Authors:  Jaime Mirowsky; Terry Gordon
Journal:  J Expo Sci Environ Epidemiol       Date:  2015-01-21       Impact factor: 5.563

Review 3.  An Evidence-Based Review of Application Devices for Nitric Oxide Concentration Determination from Exhaled Air in the Diagnosis of Inflammation and Treatment Monitoring.

Authors:  Magdalena Wyszyńska; Monika Nitsze-Wierzba; Aleksandra Czelakowska; Jacek Kasperski; Joanna Żywiec; Małgorzata Skucha-Nowak
Journal:  Molecules       Date:  2022-07-03       Impact factor: 4.927

Review 4.  Clinical application of exhaled nitric oxide measurement in pediatric lung diseases.

Authors:  Angelo Manna; Carlo Caffarelli; Margherita Varini; Carlotta Povesi Dascola; Silvia Montella; Marco Maglione; Francesco Sperlì; Francesca Santamaria
Journal:  Ital J Pediatr       Date:  2012-12-31       Impact factor: 2.638

5.  Validation of a portable nitric oxide analyzer for screening in primary ciliary dyskinesias.

Authors:  Amanda Harris; Esther Bhullar; Kerry Gove; Rhiannon Joslin; Jennifer Pelling; Hazel J Evans; Woolf T Walker; Jane S Lucas
Journal:  BMC Pulm Med       Date:  2014-02-10       Impact factor: 3.317

6.  Pilot Study of Use of Nitric Oxide in Monitoring Multiple Dental Foci in Oral Cavity-A Case Report.

Authors:  Magdalena Wyszyńska; Przemysław Rosak; Aleksandra Czelakowska; Ewa Białożyt-Bujak; Jacek Kasperski; Maciej Łopaciński; Nour Al Khatib; Małgorzata Skucha-Nowak
Journal:  Healthcare (Basel)       Date:  2022-01-20

7.  DASH for asthma: a pilot study of the DASH diet in not-well-controlled adult asthma.

Authors:  Jun Ma; Peg Strub; Phillip W Lavori; A Sonia Buist; Carlos A Camargo; Kari C Nadeau; Sandra R Wilson; Lan Xiao
Journal:  Contemp Clin Trials       Date:  2013-05-03       Impact factor: 2.226

8.  Kinetics of TH2 biomarkers in sputum of asthmatics following inhaled allergen.

Authors:  Rob G J A Zuiker; Marcella K Ruddy; Nicoletta Morelli; Robin Mogg; Veronica M Rivas; Kristien van Dyck; Inge De Lepeleire; Michael R L Tanen; J Diderik Boot; Ingrid M C Kamerling; Zuzana Diamant
Journal:  Eur Clin Respir J       Date:  2015-05-26

Review 9.  Fractional exhaled nitric oxide-measuring devices: technology update.

Authors:  Mauro Maniscalco; Carolina Vitale; Alessandro Vatrella; Antonio Molino; Andrea Bianco; Gennaro Mazzarella
Journal:  Med Devices (Auckl)       Date:  2016-06-23
  9 in total