Literature DB >> 18686460

Dermabond wound closure in primary hip arthroplasty.

Ashish Khurana1, Salim Parker, Vivek Goel, Phillip M Alderman.   

Abstract

Cyanoacrylate glues have been used in various surgical specialties for primary wound closure or as a supplement to other methods. We assessed the overall results and safety of this technique following primary hip arthroplasty. Ninety-three patients undergoing primary total hip replacement were studied. The surgical wound had been closed with subcuticular vicryl followed by the application of topical dermabond adhesive, without any additional dressings. The mean follow-up was 7.2 months. One patient suffered wound dehiscence on the third post operative day. Two patients had serous oozing from the wound for the initial 3-4 days. This technique provides an immediate water tight seal in a sterile operative environment and provides a barrier to micro organisms. It has good tensile strength, aesthetic value and patient satisfaction.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18686460

Source DB:  PubMed          Journal:  Acta Orthop Belg        ISSN: 0001-6462            Impact factor:   0.500


  13 in total

1.  Systematic review of the use of cyanoacrylate glue in addition to standard wound closure in the prevention of surgical site infection.

Authors:  Matthew Machin; Chen Liu; Alex Coupland; Alun Huw Davies; Ankur Thapar
Journal:  Int Wound J       Date:  2018-12-04       Impact factor: 3.315

2.  Skin closure with 2-octyl cyanoacrylate and polyester mesh after primary total knee arthroplasty offers superior cosmetic outcomes and patient satisfaction compared to staples: a prospective trial.

Authors:  Kavin Sundaram; Nicolas S Piuzzi; Brendan M Patterson; Kim L Stearns; Viktor E Krebs; Michael A Mont
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-11-05

Review 3.  The antibacterial effect of 2-octyl cyanoacrylate (Dermabond®) skin adhesive.

Authors:  Jeremy L Rushbrook; Grace White; Lizi Kidger; Philip Marsh; Thomas Fo Taggart
Journal:  J Infect Prev       Date:  2014-11-30

4.  Tissue Adhesive for Wound Closure Reduces Immediate Postoperative Wound Dressing Changes After Primary TKA: A Randomized Controlled Study in Simultaneous Bilateral TKA.

Authors:  Kirill Gromov; Anders Troelsen; Sofie Raaschou; Håkon Sandhold; Christian Skovgaard Nielsen; Henrik Kehlet; Henrik Husted
Journal:  Clin Orthop Relat Res       Date:  2019-09       Impact factor: 4.176

5.  A Prospective, Randomized and Controlled Study on Tissue Adhesive for Skin Incision in Total Knee Arthroplasty.

Authors:  Xiangpeng Kong; Minzhi Yang; Renwen Guo; Jiying Chen; Wei Chai; Yan Wang
Journal:  Ther Clin Risk Manag       Date:  2020-08-24       Impact factor: 2.423

6.  Improving Efficiency of Hip Fracture Care by Simplifying Wound Management and Eliminating Unnecessary Clinical Follow-Up.

Authors:  Liana Meffert; John Davison; Natalie Glass; Michael Willey
Journal:  Iowa Orthop J       Date:  2020

Review 7.  Tunable Adhesion for Bio-Integrated Devices.

Authors:  Zhaozheng Yu; Huanyu Cheng
Journal:  Micromachines (Basel)       Date:  2018-10-18       Impact factor: 2.891

8.  Octyl-2-cyanoacrylate tissue adhesive without subcuticular suture for wound closure after total hip arthroplasty: a prospective observational study on thirty-two cases with controls for 3 months follow-up.

Authors:  Li-Shen Wang; Xin-Yu Wang; Hao-Tian Tu; Yi-Fan Huang; Xin Qi; Yu-Hang Gao
Journal:  J Orthop Surg Res       Date:  2020-10-10       Impact factor: 2.359

9.  Complications of reverse shoulder arthroplasty: a concise review.

Authors:  Su Cheol Kim; Il Su Kim; Min Chang Jang; Jae Chul Yoo
Journal:  Clin Shoulder Elb       Date:  2021-03-02

10.  A prospective randomized comparison of two skin closure techniques in acetabular fracture surgery.

Authors:  Christopher D Mudd; John A Boudreau; Berton R Moed
Journal:  J Orthop Traumatol       Date:  2013-12-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.