Literature DB >> 18677365

Efficiency of capturing a phase image using cone-beam x-ray Talbot interferometry.

Wataru Yashiro1, Yoshihiro Takeda, Atsushi Momose.   

Abstract

We assesses the efficiency of x-ray Talbot interferometry (XTI), a technique based on the Talbot effect for measuring a wavefront gradient, in terms of how quickly it can capture a high-quality phase image with a large signal-to-noise ratio for a given incident photon number. Photon statistics cause errors in the phase of the moiré fringes and impose a detection limit on the wavefront gradient. The relation between the incident photon number and the detection limit is determined, and a figure of merit of XTI for a monochromatic cone beam is then defined. The dependence of the figure of merit on optical system parameters, such as grating pitch and position, is then discussed. The effects of varying the pattern height and linewidth of the second grating are shown for rectangular and trapezoidal teeth. Finally, we show how to design a practical cone-beam Talbot interferometer for certain boundary conditions.

Year:  2008        PMID: 18677365     DOI: 10.1364/josaa.25.002025

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  9 in total

1.  Scaling law for noise variance and spatial resolution in differential phase contrast computed tomography.

Authors:  Guang-Hong Chen; Joseph Zambelli; Ke Li; Nicholas Bevins; Zhihua Qi
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

2.  Low-dose, phase-contrast mammography with high signal-to-noise ratio.

Authors:  Lukas B Gromann; Dirk Bequé; Kai Scherer; Konstantin Willer; Lorenz Birnbacher; Marian Willner; Julia Herzen; Susanne Grandl; Karin Hellerhoff; Jonathan I Sperl; Franz Pfeiffer; Cristina Cozzini
Journal:  Biomed Opt Express       Date:  2016-01-07       Impact factor: 3.732

3.  Large-angle x-ray scatter in Talbot-Lau interferometry for breast imaging.

Authors:  Srinivasan Vedantham; Linxi Shi; Andrew Karellas
Journal:  Phys Med Biol       Date:  2014-10-08       Impact factor: 3.609

4.  Ellipsoidal mirror for two-dimensional 100-nm focusing in hard X-ray region.

Authors:  Hirokatsu Yumoto; Takahisa Koyama; Satoshi Matsuyama; Yoshiki Kohmura; Kazuto Yamauchi; Tetsuya Ishikawa; Haruhiko Ohashi
Journal:  Sci Rep       Date:  2017-11-27       Impact factor: 4.379

5.  In-vivo X-ray Dark-Field Chest Radiography of a Pig.

Authors:  Lukas B Gromann; Fabio De Marco; Konstantin Willer; Peter B Noël; Kai Scherer; Bernhard Renger; Bernhard Gleich; Klaus Achterhold; Alexander A Fingerle; Daniela Muenzel; Sigrid Auweter; Katharina Hellbach; Maximilian Reiser; Andrea Baehr; Michaela Dmochewitz; Tobias J Schroeter; Frieder J Koch; Pascal Meyer; Danays Kunka; Juergen Mohr; Andre Yaroshenko; Hanns-Ingo Maack; Thomas Pralow; Hendrik van der Heijden; Roland Proksa; Thomas Koehler; Nataly Wieberneit; Karsten Rindt; Ernst J Rummeny; Franz Pfeiffer; Julia Herzen
Journal:  Sci Rep       Date:  2017-07-06       Impact factor: 4.379

6.  X-ray Dark-field Radiography - In-Vivo Diagnosis of Lung Cancer in Mice.

Authors:  Kai Scherer; Andre Yaroshenko; Deniz Ali Bölükbas; Lukas B Gromann; Katharina Hellbach; Felix G Meinel; Margarita Braunagel; Jens von Berg; Oliver Eickelberg; Maximilian F Reiser; Franz Pfeiffer; Silke Meiners; Julia Herzen
Journal:  Sci Rep       Date:  2017-03-24       Impact factor: 4.379

7.  Implementation of a double-grating interferometer for phase-contrast computed tomography in a conventional system nanotom® m.

Authors:  Anna Khimchenko; Georg Schulz; Peter Thalmann; Bert Müller
Journal:  APL Bioeng       Date:  2018-01-26

8.  Probing Surface Morphology using X-ray Grating Interferometry.

Authors:  Wataru Yashiro; Susumu Ikeda; Yasuo Wada; Kentaro Totsu; Yoshio Suzuki; Akihisa Takeuchi
Journal:  Sci Rep       Date:  2019-10-01       Impact factor: 4.379

Review 9.  Quantitative X-ray phase contrast computed tomography with grating interferometry : Biomedical applications of quantitative X-ray grating-based phase contrast computed tomography.

Authors:  Lorenz Birnbacher; Eva-Maria Braig; Daniela Pfeiffer; Franz Pfeiffer; Julia Herzen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2021-04-13       Impact factor: 9.236

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.