Literature DB >> 18675608

Post operative monitoring of microvascular breast reconstructions using the implantable Cook-Swartz doppler system: a study of 145 probes & technical discussion.

J M Smit1, I S Whitaker, A G Liss, Th Audolfsson, M Kildal, R Acosta.   

Abstract

INTRODUCTION: Accurate post operative assessment of free tissue transfers is challenging despite all the subjective and objective techniques available today. In our continual search to optimise patient outcomes, we introduced the Cook-Swartz probe into our clinical practice in May 2006.
METHODS: We present our single centre experience in 103 patients undergoing 121 microvascular breast reconstructions and monitored using implantable Cook-Swartz venous dopplers between May 2006 and January 2008.
RESULTS: In total, we used 145 probes on 121 microvascular breast reconstructions (DIEP=102, SIEP=15, SGAP=4) in 103 female patients. The mean operative time was 4h and 55 min (mu=295; range 117-630; ó+/-101 min) and we suffered 2 complete flap losses. A problem with the audible signal was noted in 15 patients (4 intra-operatively). We revised 14 of the 15. All fourteen had compromised anastomoses. In the remaining case, the patient was not returned to theatre as the primary surgeon was confident there were no other signs of vascular compromise. Overall, when using the venous doppler probe we found a false positive rate of 6.7% and 0% false negatives. DISCUSSION: We advocate the use of a Cook-Swartz probe which has been well received by both surgeons, nursing staff and patients, as an adjunct to traditional clinical monitoring techniques. We also include a comprehensive experience based technical discussion concerning its application, attachment, use and post-operative removal.

Entities:  

Mesh:

Year:  2008        PMID: 18675608     DOI: 10.1016/j.bjps.2008.06.007

Source DB:  PubMed          Journal:  J Plast Reconstr Aesthet Surg        ISSN: 1748-6815            Impact factor:   2.740


  9 in total

1.  A System for Simple Real-Time Anastomotic Failure Detection and Wireless Blood Flow Monitoring in the Lower Limbs.

Authors:  Michael A Rothfuss; Nicholas G Franconi; Jignesh V Unadkat; Michael L Gimbel; Alexander Star; Marlin H Mickle; Ervin Sejdic
Journal:  IEEE J Transl Eng Health Med       Date:  2016-08-25       Impact factor: 3.316

2.  The venous anatomy of the abdominal wall for Deep Inferior Epigastric Artery (DIEP) flaps in breast reconstruction.

Authors:  Warren M Rozen; Mark W Ashton
Journal:  Gland Surg       Date:  2012-08

3.  Case report. The use of both antegrade and retrograde internal mammary vessels in a folded, stacked deep inferior epigastric artery perforator flap.

Authors:  Rodney K Chan; Wojitec Przylecki; Lifei Guo; Stephanie A Caterson
Journal:  Eplasty       Date:  2010-04-30

4.  The unsuitability of implantable Doppler probes for the early detection of renal vascular complications - a porcine model for prevention of renal transplant loss.

Authors:  Chris Amdisen; Bente Jespersen; Ulla Møldrup; Anna K Keller
Journal:  PLoS One       Date:  2017-05-25       Impact factor: 3.240

5.  Use of Near-infrared Spectroscopy and Implantable Doppler for Postoperative Monitoring of Free Tissue Transfer for Breast Reconstruction: A Systematic Review and Meta-analysis.

Authors:  Melissa Berthelot; James Ashcroft; Piers Boshier; Judith Hunter; Francis Patrick Henry; Benny Lo; Guang-Zhong Yang; Daniel Leff
Journal:  Plast Reconstr Surg Glob Open       Date:  2019-10-29

6.  Flexible Doppler ultrasound device for the monitoring of blood flow velocity.

Authors:  Fengle Wang; Peng Jin; Yunlu Feng; Ji Fu; Peng Wang; Xin Liu; Yingchao Zhang; Yinji Ma; Yingyun Yang; Aiming Yang; Xue Feng
Journal:  Sci Adv       Date:  2021-10-27       Impact factor: 14.136

7.  Patient Management Strategies in Perioperative, Intraoperative, and Postoperative Period in Breast Reconstruction With DIEP-Flap: Clinical Recommendations.

Authors:  Kuo Chen; Narasimha M Beeraka; Mikhail Y Sinelnikov; Jin Zhang; Dajiang Song; Yuanting Gu; Jingruo Li; I V Reshetov; O I Startseva; Junqi Liu; Ruitai Fan; Pengwei Lu
Journal:  Front Surg       Date:  2022-02-15

8.  Evaluation of implantable Doppler probe continuous monitoring of hepatic artery anastomosis after liver transplantation.

Authors:  Shrirang Vasant Kulkarni; Pankaj P Rao; C S Naidu; N Pathak; A K Singh
Journal:  Med J Armed Forces India       Date:  2020-06-03

9.  The efficacy of the Cook-Swartz implantable Doppler in the detection of free-flap compromise: a systematic review protocol.

Authors:  Riaz A Agha; Buket Gundogan; Alexander J Fowler; Thomas W H Bragg; Dennis P Orgill
Journal:  BMJ Open       Date:  2014-03-12       Impact factor: 2.692

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.