Literature DB >> 18672418

Spatial harmonic imaging of X-ray scattering--initial results.

Han Wen1, Eric E Bennett, Monica M Hegedus, Stefanie C Carroll.   

Abstract

Coherent X-ray scattering is related to the electron density distribution by a Fourier transform, and therefore a window into the microscopic structures of biological samples. Current techniques of scattering rely on small-angle measurements from highly collimated X-ray beams produced from synchrotron light sources. Imaging of the distribution of scattering provides a new contrast mechanism which is different from absorption radiography, but is a lengthy process of raster or line scans of the beam over the object. Here, we describe an imaging technique in the spatial frequency domain capable of acquiring both the scattering and absorption distributions in a single exposure. We present first results obtained with conventional X-ray equipment. This method interposes a grid between the X-ray source and the imaged object, so that the grid-modulated image contains a primary image and a grid harmonic image. The ratio between the harmonic and primary images is shown to be a pure scattering image. It is the auto-correlation of the electron density distribution at a specific distance. We tested a number of samples at 60-200 nm autocorrelation distance, and found the scattering images to be distinct from the absorption images and reveal new features. This technique is simple to implement, and should help broaden the imaging applications of X-ray scattering.

Entities:  

Mesh:

Year:  2008        PMID: 18672418      PMCID: PMC2882966          DOI: 10.1109/TMI.2007.912393

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

1.  Multiple-image radiography.

Authors:  Miles N Wernick; Oliver Wirjadi; Dean Chapman; Zhong Zhong; Nikolas P Galatsanos; Yongyi Yang; Jovan G Brankov; Oral Oltulu; Mark A Anastasio; Carol Muehleman
Journal:  Phys Med Biol       Date:  2003-12-07       Impact factor: 3.609

2.  Molecular dynamics of cyclically contracting insect flight muscle in vivo.

Authors:  Michael Dickinson; Gerrie Farman; Mark Frye; Tanya Bekyarova; David Gore; David Maughan; Thomas Irving
Journal:  Nature       Date:  2005-01-20       Impact factor: 49.962

3.  Multiple-image radiography for human soft tissue.

Authors:  Carol Muehleman; Jun Li; Zhong Zhong; Jovan G Brankov; Miles N Wernick
Journal:  J Anat       Date:  2006-01       Impact factor: 2.610

4.  Diffraction enhanced x-ray imaging.

Authors:  D Chapman; W Thomlinson; R E Johnston; D Washburn; E Pisano; N Gmür; Z Zhong; R Menk; F Arfelli; D Sayers
Journal:  Phys Med Biol       Date:  1997-11       Impact factor: 3.609

5.  Coherent scatter in diagnostic radiology.

Authors:  P C Johns; M J Yaffe
Journal:  Med Phys       Date:  1983 Jan-Feb       Impact factor: 4.071

  5 in total
  34 in total

1.  Multicontrast x-ray computed tomography imaging using Talbot-Lau interferometry without phase stepping.

Authors:  Nicholas Bevins; Joseph Zambelli; Ke Li; Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  Single-shot x-ray differential phase-contrast and diffraction imaging using two-dimensional transmission gratings.

Authors:  Harold H Wen; Eric E Bennett; Rael Kopace; Ashley F Stein; Vinay Pai
Journal:  Opt Lett       Date:  2010-06-15       Impact factor: 3.776

3.  A grating-based single-shot x-ray phase contrast and diffraction method for in vivo imaging.

Authors:  Eric E Bennett; Rael Kopace; Ashley F Stein; Han Wen
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

4.  Interpretation of dark-field contrast and particle-size selectivity in grating interferometers.

Authors:  Susanna K Lynch; Vinay Pai; Julie Auxier; Ashley F Stein; Eric E Bennett; Camille K Kemble; Xianghui Xiao; Wah-Keat Lee; Nicole Y Morgan; Han Harold Wen
Journal:  Appl Opt       Date:  2011-08-01       Impact factor: 1.980

5.  Fourier X-ray scattering radiography yields bone structural information.

Authors:  Han Wen; Eric E Bennett; Monica M Hegedus; Stanislas Rapacchi
Journal:  Radiology       Date:  2009-04-29       Impact factor: 11.105

6.  Motionless phase stepping in X-ray phase contrast imaging with a compact source.

Authors:  Houxun Miao; Lei Chen; Eric E Bennett; Nick M Adamo; Andrew A Gomella; Alexa M DeLuca; Ajay Patel; Nicole Y Morgan; Han Wen
Journal:  Proc Natl Acad Sci U S A       Date:  2013-11-11       Impact factor: 11.205

7.  A general theory of interference fringes in x-ray phase grating imaging.

Authors:  Aimin Yan; Xizeng Wu; Hong Liu
Journal:  Med Phys       Date:  2015-06       Impact factor: 4.071

8.  X-ray spatial frequency heterodyne imaging of protein-based nanobubble contrast agents.

Authors:  Danielle Rand; Masaki Uchida; Trevor Douglas; Christoph Rose-Petruck
Journal:  Opt Express       Date:  2014-09-22       Impact factor: 3.894

9.  Crystal analyser-based X-ray phase contrast imaging in the dark field: implementation and evaluation using excised tissue specimens.

Authors:  Masami Ando; Naoki Sunaguchi; Yanlin Wu; Synho Do; Yongjin Sung; Abner Louissaint; Tetsuya Yuasa; Shu Ichihara; Rajiv Gupta
Journal:  Eur Radiol       Date:  2013-09-19       Impact factor: 5.315

10.  Fabrication of 200 nanometer period centimeter area hard x-ray absorption gratings by multilayer deposition.

Authors:  S K Lynch; C Liu; N Y Morgan; X Xiao; A A Gomella; D Mazilu; E E Bennett; L Assoufid; F de Carlo; H Wen
Journal:  J Micromech Microeng       Date:  2012-08-23       Impact factor: 1.881

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.