Literature DB >> 18666131

Myocardial T*2 measurement in iron-overloaded thalassemia: an ex vivo study to investigate optimal methods of quantification.

Taigang He1, Peter D Gatehouse, Paul Kirk, Raad H Mohiaddin, Dudley J Pennell, David N Firmin.   

Abstract

Myocardial T*2 measurement has been increasingly used for iron quantification to assess the risk of cardiac complications in thalassemia patients. In this study the noise effects were evaluated along with different curve-fitting models on an iron overloaded ex vivo heart in order to determine the optimal method of T*2 measurement and to help understand issues affecting reproducibility and accuracy. Gradient multiecho short axis images were acquired with differing numbers of excitations to generate varying signal-to-noise ratio (SNR) images. A noise correction method was implemented; linear and nonlinear curve-fitting algorithms were compared and different curve-fitting models (monoexponential, truncation, baseline subtraction, and offset) were evaluated. This study suggests that the T*2 decay curve in an ex vivo heart can be fitted by a monoexponential model and accurate T*2 measurements can be obtained with proper noise correction. With MRI noise, T*2 is generally overestimated by including late low SNR data points, but underestimated by the offset or baseline subtraction models, which are in fact equivalent. In this situation the truncation model proves to be reproducible and more accurate than the other models. The study also shows that the nonlinear algorithm is preferred in T*2 curve fitting. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18666131     DOI: 10.1002/mrm.21625

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  33 in total

Review 1.  Magnetic resonance imaging quantification of liver iron.

Authors:  Claude B Sirlin; Scott B Reeder
Journal:  Magn Reson Imaging Clin N Am       Date:  2010-08       Impact factor: 2.266

2.  Proton density fat-fraction: a standardized MR-based biomarker of tissue fat concentration.

Authors:  Scott B Reeder; Houchun H Hu; Claude B Sirlin
Journal:  J Magn Reson Imaging       Date:  2012-07-06       Impact factor: 4.813

3.  Cardiac R2* values are independent of the image analysis approach employed.

Authors:  Antonella Meloni; Hugh Young Rienhoff; Amber Jones; Alessia Pepe; Massimo Lombardi; John C Wood
Journal:  Magn Reson Med       Date:  2013-10-01       Impact factor: 4.668

4.  A variable echo-number method for estimating R2 in MRI-based polymer gel dosimetry.

Authors:  Yoichi Watanabe; Hitoshi Kubo
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

Review 5.  Cardiovascular magnetic resonance T2* for tissue iron assessment in the heart.

Authors:  Taigang He
Journal:  Quant Imaging Med Surg       Date:  2014-10

6.  On T2* magnetic resonance and cardiac iron.

Authors:  John-Paul Carpenter; Taigang He; Paul Kirk; Michael Roughton; Lisa J Anderson; Sofia V de Noronha; Mary N Sheppard; John B Porter; J Malcolm Walker; John C Wood; Renzo Galanello; Gianluca Forni; Gualtiero Catani; Gildo Matta; Suthat Fucharoen; Adam Fleming; Michael J House; Greg Black; David N Firmin; Timothy G St Pierre; Dudley J Pennell
Journal:  Circulation       Date:  2011-03-28       Impact factor: 29.690

7.  Design and characterization of lisinopril-loaded superparamagnetic nanoparticles as a new contrast agent for in vitro, in vivo MRI imaging, diagnose the tumors and drug delivery system.

Authors:  Sajjad Abbasi Pour; Hamid Reza Shaterian
Journal:  J Mater Sci Mater Med       Date:  2017-05-11       Impact factor: 3.896

8.  Rosette Trajectories Enable Ungated, Motion-Robust, Simultaneous Cardiac and Liver T2 * Iron Assessment.

Authors:  Adam M Bush; Christopher M Sandino; Shreya Ramachandran; Frank Ong; Nicholas Dwork; Evan J Zucker; Ali B Syed; John M Pauly; Marcus T Alley; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2020-05-26       Impact factor: 4.813

9.  Myocardial T2* measurements in iron-overloaded thalassemia: An in vivo study to investigate optimal methods of quantification.

Authors:  Taigang He; Peter D Gatehouse; Gillian C Smith; Raad H Mohiaddin; Dudley J Pennell; David N Firmin
Journal:  Magn Reson Med       Date:  2008-11       Impact factor: 4.668

10.  Myocardial T2 quantitation in patients with iron overload at 3 Tesla.

Authors:  Hua Guo; Wing-Yan Au; Jerry S Cheung; Daniel Kim; Jens H Jensen; Pek-Lan Khong; Queenie Chan; Kevin C Chan; Christina Tosti; Haiying Tang; Truman R Brown; Wynnie W M Lam; Shau-Yin Ha; Gary M Brittenham; Ed X Wu
Journal:  J Magn Reson Imaging       Date:  2009-08       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.