Literature DB >> 18666128

Imaging pH using the chemical exchange saturation transfer (CEST) MRI: Correction of concomitant RF irradiation effects to quantify CEST MRI for chemical exchange rate and pH.

Phillip Zhe Sun1, A Gregory Sorensen.   

Abstract

Chemical exchange saturation transfer (CEST) MRI has been shown capable of detecting dilute labile protons and abnormal tissue glucose/oxygen metabolism, and thus, may serve as a complementary imaging technique to the conventional MRI methods. CEST imaging, however, is also dependent on experimental parameters such as the power, duration, and waveform of the irradiation RF pulse. As a result, its sensitivity and specificity for microenvironment properties such as pH is not optimal. In this study, the dependence of CEST contrast on experimental parameters was solved and an iterative compensation algorithm was proposed that corrects the experimentally measured CEST contrast from the concomitant RF irradiation effects. The proposed algorithm was verified with both numerical simulation and experimental measurements from a tissue-like pH phantom, and showed that pH derived from the compensated CEST imaging agrees reasonably well with pH-electrode measurements within 0.1 pH unit. In sum, our study validates the use of a correction algorithm to compensate CEST imaging from concomitant RF irradiation effects for accurate calibration of the chemical exchange rate, and demonstrates the feasibility of pH imaging with CEST MRI. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18666128     DOI: 10.1002/mrm.21653

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  64 in total

1.  Improved measurement of labile proton concentration-weighted chemical exchange rate (k(ws)) with experimental factor-compensated and T(1) -normalized quantitative chemical exchange saturation transfer (CEST) MRI.

Authors:  Renhua Wu; Charng-Ming Liu; Philip K Liu; Phillip Zhe Sun
Journal:  Contrast Media Mol Imaging       Date:  2012 Jul-Aug       Impact factor: 3.161

2.  Investigation of chemical exchange at intermediate exchange rates using a combination of chemical exchange saturation transfer (CEST) and spin-locking methods (CESTrho).

Authors:  Feliks Kogan; Anup Singh; Keija Cai; Mohammad Haris; Hari Hariharan; Ravinder Reddy
Journal:  Magn Reson Med       Date:  2011-10-18       Impact factor: 4.668

3.  Fast multislice pH-weighted chemical exchange saturation transfer (CEST) MRI with Unevenly segmented RF irradiation.

Authors:  Phillip Zhe Sun; Jerry S Cheung; Enfeng Wang; Thomas Benner; A Gregory Sorensen
Journal:  Magn Reson Med       Date:  2010-09-24       Impact factor: 4.668

4.  Early experience of translating pH-weighted MRI to image human subjects at 3 Tesla.

Authors:  Phillip Zhe Sun; Thomas Benner; William A Copen; A Gregory Sorensen
Journal:  Stroke       Date:  2010-10       Impact factor: 7.914

5.  Inverse Z-spectrum analysis for spillover-, MT-, and T1 -corrected steady-state pulsed CEST-MRI--application to pH-weighted MRI of acute stroke.

Authors:  Moritz Zaiss; Junzhong Xu; Steffen Goerke; Imad S Khan; Robert J Singer; John C Gore; Daniel F Gochberg; Peter Bachert
Journal:  NMR Biomed       Date:  2014-01-03       Impact factor: 4.044

Review 6.  A review of optimization and quantification techniques for chemical exchange saturation transfer MRI toward sensitive in vivo imaging.

Authors:  Jinsuh Kim; Yin Wu; Yingkun Guo; Hairong Zheng; Phillip Zhe Sun
Journal:  Contrast Media Mol Imaging       Date:  2015-01-12       Impact factor: 3.161

7.  Assessment of unilateral ureter obstruction with multi-parametric MRI.

Authors:  Feng Wang; Keiko Takahashi; Hua Li; Zhongliang Zu; Ke Li; Junzhong Xu; Raymond C Harris; Takamune Takahashi; John C Gore
Journal:  Magn Reson Med       Date:  2017-07-24       Impact factor: 4.668

8.  Sensitivity-enhanced chemical exchange saturation transfer (CEST) MRI with least squares optimization of Carr Purcell Meiboom Gill multi-echo echo planar imaging.

Authors:  Phillip Zhe Sun; Yu Wang; Jie Lu
Journal:  Contrast Media Mol Imaging       Date:  2014 Mar-Apr       Impact factor: 3.161

9.  Imaging of glutamate in the spinal cord using GluCEST.

Authors:  Feliks Kogan; Anup Singh; Catherine Debrosse; Mohammad Haris; Kejia Cai; Ravi Prakash Nanga; Mark Elliott; Hari Hariharan; Ravinder Reddy
Journal:  Neuroimage       Date:  2013-04-09       Impact factor: 6.556

10.  Investigation of optimizing and translating pH-sensitive pulsed-chemical exchange saturation transfer (CEST) imaging to a 3T clinical scanner.

Authors:  Phillip Zhe Sun; Thomas Benner; Ashok Kumar; A Gregory Sorensen
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.