Literature DB >> 18653254

Improved aortic distensibility after aortic homograft root replacement at long-term follow-up.

Attila Nemes, Tjebbe W Galema, Osama I I Soliman, Ad J J C Bogers, Folkert J ten Cate, Marcel L Geleijnse.   

Abstract

BACKGROUND: The ideal substitute for a diseased aortic valve remains unclear. Usually, the aortic full root replacement (FRR) technique is used, in which the native aortic root is removed and entirely replaced with the homograft aortic root, the coronary arteries being reimplanted into the homograft. The aim of the present study was to examine alterations in aortic size and stiffness in patients after FRR. METHODS AND PATIENTS: The study comprised 13 patients (mean age 46+/-15 years, 10 males) who underwent FRR because of acute aortic regurgitation due to endocarditis in 6 patients (46%) and aortic valve stenosis with or without regurgitation in 7 patients (54%). These patients underwent transthoracic two-dimensional echocardiography before FRR, before discharge (9+/-8 days post-FRR), and 6 months and 24 months after FRR. Systolic and diastolic ascending aortic diameters were recorded in M-mode at the middle of the ascending aorta, 3 to 4 cm above the aortic valve from a parasternal long-axis view. An aortic stiffness index (beta) was calculated. The results were compared to 13 age-, gender- and risk factor-matched controls.
RESULTS: The aortic stiffness index first non-significantly deteriorated from 12.7+/-8.1 to 16.4+/-9.1 immediately after FRR. Subsequently, an improvement to 14.2+/-7.1 (after 6 months) and 7.1+/-4.8 (after 24 months, P<0.05) was seen.
CONCLUSIONS: FRR is associated with a transient immediate post-FRR deterioration followed by a progressive improvement in aortic distensibility.

Entities:  

Mesh:

Year:  2008        PMID: 18653254     DOI: 10.1016/j.ijcard.2008.04.049

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  5 in total

1.  Effect of transcatheter aortic valve implantation on the ascending aorta's elasticity.

Authors:  Manolis Vavuranakis; Dimitrios A Vrachatis; Harisios Boudoulas; Theodore G Papaioannou; Carmen Moldovan; Maria G Kariori; Konstantinos I Kalogeras; Panagiota G Pietri; Constantinos Tentolouris; Christodoulos Stefanadis
Journal:  Clin Res Cardiol       Date:  2012-05-16       Impact factor: 5.460

2.  Arterial Stiffness in Aortic Stenosis: Relationship with Severity and Echocardiographic Procedures Response.

Authors:  Giuseppe Bruschi; Alessandro Maloberti; Paola Sormani; Giulia Colombo; Stefano Nava; Paola Vallerio; Francesca Casadei; Jolie Bruno; Antonella Moreo; Bruno Merlanti; Claudio Russo; Fabrizio Oliva; Silvio Klugmann; Cristina Giannattasio
Journal:  High Blood Press Cardiovasc Prev       Date:  2017-01-11

3.  Short-term changes of blood pressure and aortic stiffness in older patients after transcatheter aortic valve implantation.

Authors:  Jeannette A Goudzwaard; Eleonora Disegna; Marjo Jag de Ronde-Tillmans; Mattie J Lenzen; Peter Pt de Jaegere; Francesco Us Mattace-Raso
Journal:  Clin Interv Aging       Date:  2019-08-02       Impact factor: 4.458

4.  Assessment of aortic stiffness by cardiovascular magnetic resonance following the treatment of severe aortic stenosis by TAVI and surgical AVR.

Authors:  Tarique Al Musa; Akhlaque Uddin; Timothy A Fairbairn; Laura E Dobson; Steven P Sourbron; Christopher D Steadman; Manish Motwani; Ananth Kidambi; David P Ripley; Peter P Swoboda; Adam K McDiarmid; Bara Erhayiem; James J Oliver; Daniel J Blackman; Sven Plein; Gerald P McCann; John P Greenwood
Journal:  J Cardiovasc Magn Reson       Date:  2016-06-10       Impact factor: 5.364

5.  Effects of transcatheter aortic valve implantation on ascending aorta wall elastic properties: Tissue Doppler imaging and strain Doppler echocardiography study.

Authors:  Enrico Vizzardi; Edoardo Sciatti; Ivano Bonadei; Antonio D'Aloia; Sandro Gelsomino; Roberto Lorusso; Federica Ettori; Marco Metra
Journal:  Int J Cardiol Heart Vessel       Date:  2014-04-26
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.