Literature DB >> 1864957

Three-dimensional characterization of human ventricular myofiber architecture by ultrasonic backscatter.

S A Wickline1, E D Verdonk, J G Miller.   

Abstract

Normal human left ventricular architecture comprises a highly aligned array of cardiac myofibers whose orientation depends on transmural location. This study was designed to determine whether measurement of integrated backscatter could be used detect the progressive transmural shift of myofiber alignment that occurs from epicardium to endocardium in human ventricular wall segments. Integrated backscatter was measured at 32 transmural levels in seven cylindrical biopsy specimens (1.4 cm diam) sampled from normal regions of six explanted fixed human hearts by insonification of samples at 180 independent angles in 2 degrees steps around their entire circumference with a 5-MHz broadband piezoelectric transducer. Histologic analysis was performed to determine fiber orientation. Integrated backscatter varied approximately as a sinusoidal function of the angle of insonification at each transmural level. Greater integrated backscatter was observed for insonification perpendicular as compared with parallel to fibers (difference = 14.5 +/- 0.6 dB). Ultrasonic analysis revealed a progressive transmural shift in fiber orientation of approximately 9.2 +/- 0.7 degrees/mm of tissue. Histologic analysis revealed a concordant shift in fiber orientation of 7.9 +/- 0.8 degrees/mm of tissue. Thus, human myocardium manifests anisotropy of ultrasonic scattering that may be useful for characterization of the intramural fiber alignment and overall three-dimensional organization of cardiac myofibers.

Entities:  

Mesh:

Year:  1991        PMID: 1864957      PMCID: PMC295352          DOI: 10.1172/JCI115323

Source DB:  PubMed          Journal:  J Clin Invest        ISSN: 0021-9738            Impact factor:   14.808


  29 in total

1.  Ultrasonic tissue characterization: prospects for clinical cardiology.

Authors:  S A Wickline; B E Sobel
Journal:  J Am Coll Cardiol       Date:  1989-12       Impact factor: 24.094

2.  Ultrasonic tissue characterization with a real time integrated backscatter imaging system in normal and aging human hearts.

Authors:  T Masuyama; U Nellessen; I Schnittger; T L Tye; W L Haskell; R L Popp
Journal:  J Am Coll Cardiol       Date:  1989-12       Impact factor: 24.094

3.  Cyclic variation of ultrasound backscatter in normal myocardium is view dependent: clinical studies with a real-time backscatter imaging system.

Authors:  B F Vandenberg; L Rath; T A Shoup; R E Kerber; S M Collins; D J Skorton
Journal:  J Am Soc Echocardiogr       Date:  1989 Sep-Oct       Impact factor: 5.251

4.  Constitutive relations and finite deformations of passive cardiac tissue II: stress analysis in the left ventricle.

Authors:  J D Humphrey; F C Yin
Journal:  Circ Res       Date:  1989-09       Impact factor: 17.367

5.  Sensitive detection of the effects of reperfusion on myocardium by ultrasonic tissue characterization with integrated backscatter.

Authors:  S A Wickline; L J Thomas; J G Miller; B E Sobel; J E Perez
Journal:  Circulation       Date:  1986-08       Impact factor: 29.690

6.  Stress distribution in the canine left ventricle during diastole and systole.

Authors:  D D Streeter; R N Vaishnav; D J Patel; H M Spotnitz; J Ross; E H Sonnenblick
Journal:  Biophys J       Date:  1970-04       Impact factor: 4.033

7.  Early identification with ultrasonic integrated backscatter of viable but stunned myocardium in dogs.

Authors:  M R Milunski; G A Mohr; K A Wear; B E Sobel; J G Miller; S A Wickline
Journal:  J Am Coll Cardiol       Date:  1989-08       Impact factor: 24.094

8.  Ultrasonic tissue characterization with integrated backscatter. Acute myocardial ischemia, reperfusion, and stunned myocardium in patients.

Authors:  M R Milunski; G A Mohr; J E Pérez; Z Vered; K A Wear; C J Gessler; B E Sobel; J G Miller; S A Wickline
Journal:  Circulation       Date:  1989-09       Impact factor: 29.690

9.  Ultrasound integrated backscatter tissue characterization of remote myocardial infarction in human subjects.

Authors:  Z Vered; G A Mohr; B Barzilai; C J Gessler; S A Wickline; K A Wear; T A Shoup; A N Weiss; B E Sobel; J G Miller
Journal:  J Am Coll Cardiol       Date:  1989-01       Impact factor: 24.094

10.  Ultrasonic tissue characterization of human hypertrophied hearts in vivo with cardiac cycle-dependent variation in integrated backscatter.

Authors:  T Masuyama; F G St Goar; T L Tye; G Oppenheim; I Schnittger; R L Popp
Journal:  Circulation       Date:  1989-10       Impact factor: 29.690

View more
  11 in total

1.  Simulating cardiac ultrasound image based on MR diffusion tensor imaging.

Authors:  Xulei Qin; Silun Wang; Ming Shen; Guolan Lu; Xiaodong Zhang; Mary B Wagner; Baowei Fei
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

Review 2.  Left ventricular form and function revisited: applied translational science to cardiovascular ultrasound imaging.

Authors:  Partho P Sengupta; Vijay K Krishnamoorthy; Josef Korinek; Jagat Narula; Mani A Vannan; Steven J Lester; Jamil A Tajik; James B Seward; Bijoy K Khandheria; Marek Belohlavek
Journal:  J Am Soc Echocardiogr       Date:  2007-05       Impact factor: 5.251

3.  DTI template-based estimation of cardiac fiber orientations from 3D ultrasound.

Authors:  Xulei Qin; Baowei Fei
Journal:  Med Phys       Date:  2015-06       Impact factor: 4.071

4.  Extracting Cardiac Myofiber Orientations from High Frequency Ultrasound Images.

Authors:  Xulei Qin; Zhibin Cong; Rong Jiang; Ming Shen; Mary B Wagner; Paul Kishbom; Baowei Fei
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-03-29

5.  Imaging technologies for cardiac fiber and heart failure: a review.

Authors:  Shana R Watson; James D Dormer; Baowei Fei
Journal:  Heart Fail Rev       Date:  2018-03       Impact factor: 4.214

6.  Quantifying Backscatter Anisotropy Using the Reference Phantom Method.

Authors:  Quinton W Guerrero; Ivan M Rosado-Mendez; Lindsey C Drehfal; Helen Feltovich; Timothy J Hall
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-04-27       Impact factor: 2.725

7.  Accuracy and reproducibility of strain by speckle tracking in pediatric subjects with normal heart and single ventricular physiology: a two-dimensional speckle-tracking echocardiography and magnetic resonance imaging correlative study.

Authors:  Gautam K Singh; Brian Cupps; Michael Pasque; Pamela K Woodard; Mark R Holland; Achiau Ludomirsky
Journal:  J Am Soc Echocardiogr       Date:  2010-09-18       Impact factor: 5.251

8.  Extensible behavior of titin in the miniswine left ventricle.

Authors:  Martin M Lewinter; Joseph Popper; Mark McNabb; Lori Nyland; Stephen B Bell; Henk Granzier
Journal:  Circulation       Date:  2010-02-01       Impact factor: 29.690

9.  Ultrasound backscatter tensor imaging (BTI): analysis of the spatial coherence of ultrasonic speckle in anisotropic soft tissues.

Authors:  Clement Papadacci; Mickael Tanter; Mathieu Pernot; Mathias Fink
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-06       Impact factor: 2.725

Review 10.  Physiological basis in the assessment of myocardial mechanics using speckle-tracking echocardiography 2D. Part I.

Authors:  Wojciech Mądry; Maciej Aleksander Karolczak
Journal:  J Ultrason       Date:  2016-06-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.