Literature DB >> 18649060

Side-by-side false and true lumen stenting for recanalization of the chronically occluded right coronary artery.

Kenan Omurlu1, Ozcan Ozeke.   

Abstract

Subintimal or false lumen stent deployment is a rare complication of percutaneous coronary interventions. The most balloon-induced small non-flow limiting dissections heal spontaneously and can be treated medically with close observation if distal coronary flow is not compromised. However, the complex and severe flow-limiting postprocedural dissections may result in abrupt vessel closure and thrombosis, with ensuing myocardial ischemia and necrosis, and can be treated effectively by coronary stenting. It is essential to ensure that the guide-wire is in the true lumen before placing the stent in total occlusive lesions, otherwise the stent placement will impair distal coronary flow. We present here an interesting case of successful coronary recanalization despite false lumen stenting of the proximal right coronary artery followed by true lumen stenting.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18649060     DOI: 10.1007/s00380-008-1052-y

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  9 in total

1.  Compression of a subintimal or false lumen stent by stenting in the true lumen.

Authors:  G S Krivonyak; S G Warren
Journal:  J Invasive Cardiol       Date:  2001-10       Impact factor: 2.022

2.  A novel use of cutting balloon in treating coronary artery dissection that developed during PCI.

Authors:  Shigenori Ito; Shinsuke Ojio; Takahiko Suzuki
Journal:  J Invasive Cardiol       Date:  2003-04       Impact factor: 2.022

Review 3.  Coronary artery dissection and perforation complicating percutaneous coronary intervention.

Authors:  Jason H Rogers; John M Lasala
Journal:  J Invasive Cardiol       Date:  2004-09       Impact factor: 2.022

4.  Treating chronic total occlusions using subintimal tracking and reentry: the STAR technique.

Authors:  Antonio Colombo; Ghada W Mikhail; Iassen Michev; Ioannis Iakovou; Flavio Airoldi; Alaide Chieffo; Renata Rogacka; Mauro Carlino; Matteo Montorfano; Giuseppe M Sangiorgi; Nicola Corvaja; Goran Stankovic
Journal:  Catheter Cardiovasc Interv       Date:  2005-04       Impact factor: 2.692

5.  Postprocedural resistance of the target lesion is a strong predictor of subsequent revascularization: assessment by a novel lesion-specific physiological parameter, the epicardial resistance index.

Authors:  Kazuhito Suzuki; Yukio Tsurumi; Yuji Fuda; Yasuhiro Ishii; Atsushi Takagi; Nobuhisa Hagiwara; Hiroshi Kasanuki
Journal:  Heart Vessels       Date:  2007-05-21       Impact factor: 2.037

6.  Impact of post-dilatation with a focal expanding balloon for optimization of intracoronary stenting.

Authors:  Fumiaki Mori; Yukio Tsurumi; Nobuhisa Hagiwara; Hiroshi Kasanuki
Journal:  Heart Vessels       Date:  2007-05-21       Impact factor: 2.037

7.  In-hospital morbidity and mortality in patients undergoing elective coronary angioplasty.

Authors:  C E Bredlau; G S Roubin; P P Leimgruber; J S Douglas; S B King; A R Gruentzig
Journal:  Circulation       Date:  1985-11       Impact factor: 29.690

8.  Short- and long-term evolution of unstented nonocclusive coronary dissection after coronary angioplasty.

Authors:  A Cappelletti; A Margonato; G Rosano; A Mailhac; F Veglia; A Colombo; S L Chierchia
Journal:  J Am Coll Cardiol       Date:  1999-11-01       Impact factor: 24.094

9.  Uncomplicated moderate coronary artery dissections after balloon angioplasty: good outcome without stenting.

Authors:  M Albertal; G Van Langenhove; E Regar; I P Kay; D Foley; G Sianos; K Kozuma; T Beijsterveldt; S G Carlier; J A Belardi; E Boersma; J E Sousa; B de Bruyne; P W Serruys
Journal:  Heart       Date:  2001-08       Impact factor: 5.994

  9 in total
  2 in total

1.  Fatigue life analysis and experimental verification of coronary stent.

Authors:  Jianjun Li; Qiyi Luo; Zhiyong Xie; Yu Li; Yanjun Zeng
Journal:  Heart Vessels       Date:  2010-07-31       Impact factor: 2.037

2.  The double helix angiography of right coronary arteries: false lumen stenting of a type F right coronary artery spiral dissection with late recanalization of the true lumen and occlusion of the stented false lumen.

Authors:  Anthony W Wassef; Iain Kirkpatrick; Kunal Minhas; Amrit Malik; Malek Kass; Farrukh Hussain
Journal:  Heart Int       Date:  2014-08-19
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.