Literature DB >> 18644672

Determination of lead in wine and rum samples by flow injection-hydride generation-atomic absorption spectrometry.

Latif Elçi1, Zikri Arslan, Julian F Tyson.   

Abstract

A method for direct determination of lead in wine and rum samples was developed, using a flow injection hydride generation system coupled to an atomic absorption spectrometer with flame-quartz atomizer (FI-HG-AAS). Lead hyride (PbH(4)) was generated using potassium ferricyanide (K(3)Fe(CN)(6)), as oxidant and sodium tetrahydroborate (NaBH(4)) as reductant. Samples were acidified to 0.40% (v/v) HCl for wine and to 0.30% (v/v) HCl for rum, which were then mixed on-line with 3% (m/v) K(3)Fe(CN)(6) solution in 0.03% (v/v) HCl prior to reaction with 0.2% (m/v) alkaline NaBH(4) solution. Lead contents of a rum and two different red wine samples were determined by FI-HG-AAS agreed with those obtained by ICP-MS. The analytical figures of merit of method developed were determined. The calibration curve was linear up to 8.0 microg L(-1) Pb with a regression coefficient of 0.998. The relative error was lower than 4.58%. The relative standard deviation (n=7) was better than 12%. A detection limit of 0.16 microg L(-1) was achieved for a sample volume of 170 microL.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18644672     DOI: 10.1016/j.jhazmat.2008.05.113

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  6 in total

1.  On-line chemical vapour generation of cadmium in the presence of hexacyanochromate(III) for determination by inductively coupled plasma mass spectrometry (ICP-MS).

Authors:  Vedat Yilmaz; Lakeysha Rose; Zikri Arslan; Maria D Little
Journal:  J Anal At Spectrom       Date:  2012-11-01       Impact factor: 4.023

2.  Simultaneous generation of hydrides of bismuth, lead and tin in the presence of ferricyanide and application to determination in biominerals by ICP-AES.

Authors:  Domingos D Afonso; Sitki Baytak; Zikri Arslan
Journal:  J Anal At Spectrom       Date:  2010       Impact factor: 4.023

3.  Determination of lead by hydride generation inductively coupled plasma mass spectrometry (HG-ICP-MS): on-line generation of plumbane using potassium hexacyanomanganate(III).

Authors:  Vedat Yilmaz; Zikri Arslan; LaKeysha Rose
Journal:  Anal Chim Acta       Date:  2012-11-29       Impact factor: 6.558

4.  Determination of Selected Metals in Fruit Wines by Spectroscopic Techniques.

Authors:  Justyna Płotka-Wasylka; Małgorzata Rutkowska; Bartłomiej Cieślik; Alan Tyburcy; Jacek Namieśnik
Journal:  J Anal Methods Chem       Date:  2017-10-31       Impact factor: 2.193

5.  Determination of Metals Content in Wine Samples by Inductively Coupled Plasma-Mass Spectrometry.

Authors:  Justyna Płotka-Wasylka; Marcin Frankowski; Vasil Simeonov; Żaneta Polkowska; Jacek Namieśnik
Journal:  Molecules       Date:  2018-11-05       Impact factor: 4.411

6.  Masking Agents Evaluation for Lead Determination by Flow Injection-Hydride Generation-Atomic Fluorescence Spectrometry Technique: Effect of KI, L-Cysteine, and 1,10-Phenanthroline.

Authors:  Blanca G Beltrán; Luz O Leal; Laura Ferrer; Víctor Cerdà
Journal:  Int J Anal Chem       Date:  2016-04-11       Impact factor: 1.885

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.