Literature DB >> 18641069

Minimizing pulling geometry errors in atomic force microscope single molecule force spectroscopy.

Monica Rivera1, Whasil Lee, Changhong Ke, Piotr E Marszalek, Daniel G Cole, Robert L Clark.   

Abstract

In atomic force microscopy-based single molecule force spectroscopy (AFM-SMFS), it is assumed that the pulling angle is negligible and that the force applied to the molecule is equivalent to the force measured by the instrument. Recent studies, however, have indicated that the pulling geometry errors can drastically alter the measured force-extension relationship of molecules. Here we describe a software-based alignment method that repositions the cantilever such that it is located directly above the molecule's substrate attachment site. By aligning the applied force with the measurement axis, the molecule is no longer undergoing combined loading, and the full force can be measured by the cantilever. Simulations and experimental results verify the ability of the alignment program to minimize pulling geometry errors in AFM-SMFS studies.

Mesh:

Substances:

Year:  2008        PMID: 18641069      PMCID: PMC2553119          DOI: 10.1529/biophysj.108.138842

Source DB:  PubMed          Journal:  Biophys J        ISSN: 0006-3495            Impact factor:   4.033


  12 in total

1.  Force Spectroscopy of Molecular Systems-Single Molecule Spectroscopy of Polymers and Biomolecules.

Authors: 
Journal:  Angew Chem Int Ed Engl       Date:  2000-09-15       Impact factor: 15.336

Review 2.  Single molecule force spectroscopy in biology using the atomic force microscope.

Authors:  J Zlatanova; S M Lindsay; S H Leuba
Journal:  Prog Biophys Mol Biol       Date:  2000       Impact factor: 3.667

3.  Distance measurement by circular scanning of the excitation beam in the two-photon microscope.

Authors:  Katarina Kis-Petikova; Enrico Gratton
Journal:  Microsc Res Tech       Date:  2004-01-01       Impact factor: 2.769

4.  Force spectroscopy of single biomolecules.

Authors:  Matthias Rief; Helmut Grubmüller
Journal:  Chemphyschem       Date:  2002-03-12       Impact factor: 3.102

5.  Atomic force microscope.

Authors: 
Journal:  Phys Rev Lett       Date:  1986-03-03       Impact factor: 9.161

6.  Microfabricated torsion levers optimized for low force and high-frequency operation in fluids.

Authors:  Arthur Beyder; Frederick Sachs
Journal:  Ultramicroscopy       Date:  2006-05-11       Impact factor: 2.689

7.  Pulling geometry-induced errors in single molecule force spectroscopy measurements.

Authors:  Changhong Ke; Yong Jiang; Monica Rivera; Robert L Clark; Piotr E Marszalek
Journal:  Biophys J       Date:  2007-02-26       Impact factor: 4.033

8.  Dynamic strength of molecular adhesion bonds.

Authors:  E Evans; K Ritchie
Journal:  Biophys J       Date:  1997-04       Impact factor: 4.033

9.  Reversible unfolding of individual titin immunoglobulin domains by AFM.

Authors:  M Rief; M Gautel; F Oesterhelt; J M Fernandez; H E Gaub
Journal:  Science       Date:  1997-05-16       Impact factor: 47.728

10.  Stretching short biopolymers by fields and forces.

Authors:  Yuko Hori; Ashok Prasad; Jané Kondev
Journal:  Phys Rev E Stat Nonlin Soft Matter Phys       Date:  2007-04-03
View more
  1 in total

Review 1.  Experimental and computational characterization of biological liquid crystals: a review of single-molecule bioassays.

Authors:  Kilho Eom; Jaemoon Yang; Jinsung Park; Gwonchan Yoon; Young Soo Sohn; Shinsuk Park; Dae Sung Yoon; Sungsoo Na; Taeyun Kwon
Journal:  Int J Mol Sci       Date:  2009-09-10       Impact factor: 6.208

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.