Literature DB >> 1864034

Noncemented porous-coated anatomic total hip arthroplasty.

B M Dodge1, R Fitzrandolph, D N Collins.   

Abstract

In 1984, as an alternate to the acrylic fixation of the components of total hip arthroplasty, the use of an uncemented porous-coated anatomic (PCA) hip system with a beaded porous coating to achieve biologic fixation was initiated. Since then, 44 patients with cementless acetabular components and 35 patients with cementless femoral components have been followed for a minimum of 24 months and an average of 37 months. Harris hip scores averaged 90.5 at most recent follow-up intervals. No reoperations were necessary for failures of fixation or change in position of the acetabular component. Ominous roentgenographic signs such as progressive bead shedding, progressive radiolucencies, or progressive component migration have not occurred. Two femoral component revisions have been necessary: one for intractable pain and one for pain and roentgenographic loosening. Although thigh pain has been prevalent (20%), all patients have been accommodated and have retained stable hip scores. Progressive radiolucencies and progressive implant subsidence have been rare occurrences. The authors continue to use the cementless acetabular component in all cases of total hip arthroplasty in which initial stability can be obtained. It is their preference to cement the femoral component in patients over 65 or when initial stability cannot be achieved.

Entities:  

Mesh:

Year:  1991        PMID: 1864034

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  6 in total

1.  Follow-up (6-9 years) results of the uncemented CLS Spotorno stem.

Authors:  J U Bulow; G Scheller; P Arnold; M Synatschke; L Jani
Journal:  Arch Orthop Trauma Surg       Date:  1996       Impact factor: 3.067

2.  What works best, a cemented or cementless primary total hip arthroplasty?: minimum 17-year followup of a randomized controlled trial.

Authors:  Kristoff Corten; Robert B Bourne; Kory D Charron; Keegan Au; Cecil H Rorabeck
Journal:  Clin Orthop Relat Res       Date:  2010-07-13       Impact factor: 4.176

3.  Uncemented porous-coated anatomic total hip replacement in Chinese patients.

Authors:  K H Chiu; W Y Shen; K M Chan
Journal:  Int Orthop       Date:  1995       Impact factor: 3.075

4.  Uncemented total hip replacements and thigh pain.

Authors:  G Petrou; M Gavras; A Diamantopoulos; T Kapetsis; N Kremmydas; A Kouzoupis
Journal:  Arch Orthop Trauma Surg       Date:  1994       Impact factor: 3.067

5.  Increased risk of periprosthetic femur fractures associated with a unique cementless stem design.

Authors:  Chad D Watts; Matthew P Abdel; David G Lewallen; Daniel J Berry; Arlen D Hanssen
Journal:  Clin Orthop Relat Res       Date:  2014-12-12       Impact factor: 4.176

6.  Accelerated polyethylene wear and early failure of the uncemented Reflection acetabular component: a ten to fifteen-year follow-up study.

Authors:  Nicholas D Clement; Martin Mitchell; Morag E Trayner; Daniel E Porter; Graham M Lawson; Richard Burnett
Journal:  Int Orthop       Date:  2013-08-22       Impact factor: 3.075

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.