Literature DB >> 18634132

Heart stroke volume and cardiac output by four-dimensional ultrasound in normal fetuses.

F S Molina1, C Faro, A Sotiriadis, T Dagklis, K H Nicolaides.   

Abstract

OBJECTIVE: To establish reference intervals for fetal heart stroke volume and cardiac output with gestation.
METHODS: Fetal heart ventricular volumes were measured using the four-dimensional (4D) spatiotemporal imaging correlation (STIC) ultrasound technique in 140 normal singleton pregnancies at 12-34 weeks' gestation. The Virtual Organ Computer-aided AnaLysis (VOCAL) technique was used to obtain a sequence of six sections of each ventricular volume in systole and diastole. Each volume was obtained after a 30 degrees rotation from the previous one around a fixed axis extending from the apex of the heart to the point that divides symmetrically each atrioventricular valve. The contour of each ventricle was drawn manually and the 4D volumes of the left and right ventricle in systole and diastole were estimated. The stroke volume for each ventricle was then calculated by subtracting the one in systole from the one in diastole and the cardiac output was calculated by multiplying the stroke volume by the fetal heart rate. In 50 cases the stroke volumes were measured by the same sonographer twice and the intraobserver agreement of measurements was calculated.
RESULTS: The left and right stroke volume and cardiac output increased exponentially with gestation, from respective mean values of 0.02 mL, 0.01 mL, 2.39 mL/min and 1.80 mL/min at 12 weeks to 0.30 mL, 0.32 mL, 43.46 mL/min and 46.72 mL/min at 20 weeks, and 2.07 mL, 2.67 mL, 284.71 mL/min and 365.99 mL/min at 34 weeks. The ratio of right to left stroke volume increased significantly with gestation from about 0.97 at 12 weeks to 1.13 at 34 weeks. In the Bland-Altman test, the mean percentage difference and 95% limits of intraobserver agreement for left stroke volume and right stroke volume were - 2.1 (-18.4, 14.2)% and - 0.8 (-16.4, 18.0)%, respectively.
CONCLUSIONS: In normal fetuses the stroke volume and cardiac output increase between 12 and 34 weeks' gestation. The extent to which, in pathological pregnancies, possible deviations in these measurements from normal prove to be useful in the prediction of outcome remains to be determined. (c) 2008 ISUOG. Published by John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2008        PMID: 18634132     DOI: 10.1002/uog.5374

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  18 in total

1.  Prospective evaluation of the fetal heart using Fetal Intelligent Navigation Echocardiography (FINE).

Authors:  M Garcia; L Yeo; R Romero; D Haggerty; I Giardina; S S Hassan; T Chaiworapongsa; E Hernandez-Andrade
Journal:  Ultrasound Obstet Gynecol       Date:  2016-03-10       Impact factor: 7.299

2.  Feasibility of automated fetal fractional shortening measurement with two-dimensional tracking and construction of a reference range for normal fetuses.

Authors:  Sumito Nagasaki; Masahiko Nakata; Mayumi Takano; Kento Usui; Junya Sakuma; Eijiro Hayata; Mineto Morita
Journal:  J Med Ultrason (2001)       Date:  2019-04-05       Impact factor: 1.314

3.  Fetal Physiologically Based Pharmacokinetic Models: Systems Information on Fetal Cardiac Output and Its Distribution to Different Organs during Development.

Authors:  Khaled Abduljalil; Xian Pan; Ruth Clayton; Trevor N Johnson; Masoud Jamei
Journal:  Clin Pharmacokinet       Date:  2021-01-24       Impact factor: 6.447

4.  Reference Ranges of Fetal Cardiac Biometric Parameters Using Three-Dimensional Ultrasound with Spatiotemporal Image Correlation M Mode and Their Applicability in Congenital Heart Diseases.

Authors:  Giselle Darahem Tedesco; Marilim de Souza Bezerra; Fernanda Silveira Bello Barros; Wellington P Martins; Luciano Marcondes Machado Nardozza; Milene Carvalho Carrilho; Antonio Fernandes Moron; Francisco Herlânio Costa Carvalho; Liliam Cristine Rolo; Edward Araujo Júnior
Journal:  Pediatr Cardiol       Date:  2016-11-23       Impact factor: 1.655

5.  A Prospective Study of the Use of Fetal Intelligent Navigation Echocardiography (FINE) to Obtain Standard Fetal Echocardiography Views.

Authors:  Paola Veronese; Gianna Bogana; Alessia Cerutti; Lami Yeo; Roberto Romero; Maria Teresa Gervasi
Journal:  Fetal Diagn Ther       Date:  2016-06-17       Impact factor: 2.587

Review 6.  Three- and four-dimensional ultrasound in fetal echocardiography: an up-to-date overview.

Authors:  B M E Adriaanse; J M G van Vugt; M C Haak
Journal:  J Perinatol       Date:  2016-03-10       Impact factor: 2.521

7.  Fetal cardiac ventricular volume, cardiac output, and ejection fraction determined with 4-dimensional ultrasound using spatiotemporal image correlation and virtual organ computer-aided analysis.

Authors:  Neil Hamill; Lami Yeo; Roberto Romero; Sonia S Hassan; Stephen A Myers; Pooja Mittal; Juan Pedro Kusanovic; Mamtha Balasubramaniam; Tinnakorn Chaiworapongsa; Edi Vaisbuch; Jimmy Espinoza; Francesca Gotsch; Luis F Goncalves; Wesley Lee
Journal:  Am J Obstet Gynecol       Date:  2011-04-30       Impact factor: 8.661

8.  Repeatability and reproducibility of fetal cardiac ventricular volume calculations using spatiotemporal image correlation and virtual organ computer-aided analysis.

Authors:  Neil Hamill; Roberto Romero; Sonia S Hassan; Wesley Lee; Stephen A Myers; Pooja Mittal; Juan Pedro Kusanovic; Tinnakorn Chaiworapongsa; Edi Vaisbuch; Jimmy Espinoza; Francesca Gotsch; Angela Carletti; Luís F Gonçalves; Lami Yeo
Journal:  J Ultrasound Med       Date:  2009-10       Impact factor: 2.153

9.  The fetal cardiovascular response to increased placental vascular impedance to flow determined with 4-dimensional ultrasound using spatiotemporal image correlation and virtual organ computer-aided analysis.

Authors:  Neil Hamill; Roberto Romero; Sonia Hassan; Wesley Lee; Stephen A Myers; Pooja Mittal; Juan Pedro Kusanovic; Mamtha Balasubramaniam; Tinnakorn Chaiworapongsa; Edi Vaisbuch; Jimmy Espinoza; Francesca Gotsch; Luis F Goncalves; Shali Mazaki-Tovi; Offer Erez; Edgar Hernandez-Andrade; Lami Yeo
Journal:  Am J Obstet Gynecol       Date:  2012-12-07       Impact factor: 8.661

10.  Real-time 3-dimensional echocardiographic assessment of ventricular volume, mass, and function in human fetuses.

Authors:  Minjuan Zheng; Micheal Schaal; Yan Chen; Xiaokui Li; Weihui Shentu; Pengyuan Zhang; Muhammad Ashraf; Shuping Ge; David J Sahn
Journal:  PLoS One       Date:  2013-03-14       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.