Literature DB >> 18628096

Virtual 3D microscopy using multiplane whole slide images in diagnostic pathology.

Thomas Kalinski1, Ralf Zwönitzer, Saadettin Sel, Matthias Evert, Thomas Guenther, Harald Hofmann, Johannes Bernarding, Albert Roessner.   

Abstract

To reproduce focusing in virtual microscopy, it is necessary to construct 3-dimensional (3D) virtual slides composed of whole slide images with different focuses. As focusing is frequently used for the assessment of Helicobacter pylori colonization in diagnostic pathology, we prepared virtual 3D slides with up to 9 focus planes from 144 gastric biopsy specimens with or without H pylori gastritis. The biopsy specimens were diagnosed in a blinded manner by 3 pathologists according to the updated Sydney classification using conventional microscopy, virtual microscopy with a single focus plane, and virtual 3D microscopy with 5 and 9 focus planes enabling virtual focusing. Regarding the classification of H pylori, we found a positive correlation between the number of focus planes used in virtual microscopy and the number of correct diagnoses as determined by conventional microscopy. Concerning H pylori positivity, the specificity and sensitivity of virtual 3D microscopy using virtual slides with 9 focus planes achieved a minimum of 0.95 each, which was approximately the same as in conventional microscopy. We consider virtual 3D microscopy appropriate for primary diagnosis of H pylori gastritis and equivalent to conventional microscopy.

Entities:  

Mesh:

Year:  2008        PMID: 18628096     DOI: 10.1309/QAM22Y85QCV5JM47

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  17 in total

1.  [Pathowiki. A free expert database for pathology].

Authors:  M Rossner; F Rossner; R Zwönitzer; T Süss; H Hofmann; A Roessner; T Kalinski
Journal:  Pathologe       Date:  2012-03       Impact factor: 1.011

Review 2.  Review of Telemicrobiology.

Authors:  Daniel D Rhoads; Blaine A Mathison; Henry S Bishop; Alexandre J da Silva; Liron Pantanowitz
Journal:  Arch Pathol Lab Med       Date:  2015-08-28       Impact factor: 5.534

3.  [Virtual microscopy and routine diagnostics. A discussion paper].

Authors:  P Hufnagl; K Schlüns
Journal:  Pathologe       Date:  2008-11       Impact factor: 1.011

4.  Digital imaging in cytopathology.

Authors:  Walid E Khalbuss; Liron Pantanowitz; Anil V Parwani
Journal:  Patholog Res Int       Date:  2011-07-19

5.  Telecytology: Clinical applications, current challenges, and future benefits.

Authors:  Michael Thrall; Liron Pantanowitz; Walid Khalbuss
Journal:  J Pathol Inform       Date:  2011-12-26

6.  A virtual microscope for academic medical education: the pate project.

Authors:  Christoph Brochhausen; Hinrich B Winther; Christian Hundt; Volker H Schmitt; Elmar Schömer; C James Kirkpatrick
Journal:  Interact J Med Res       Date:  2015-05-11

7.  Linking whole-slide microscope images with DICOM by using JPEG2000 interactive protocol.

Authors:  Vilppu J Tuominen; Jorma Isola
Journal:  J Digit Imaging       Date:  2009-05-05       Impact factor: 4.056

8.  Optimal z-axis scanning parameters for gynecologic cytology specimens.

Authors:  Amber D Donnelly; Maheswari S Mukherjee; Elizabeth R Lyden; Julia A Bridge; Subodh M Lele; Najia Wright; Mary F McGaughey; Alicia M Culberson; Adam J Horn; Whitney R Wedel; Stanley J Radio
Journal:  J Pathol Inform       Date:  2013-12-31

9.  Investigation of scanning parameters for thyroid fine needle aspiration cytology specimens: A pilot study.

Authors:  Maheswari S Mukherjee; Amber D Donnelly; Elizabeth R Lyden; Whitney R Wedel; Mary F McGaughey; John J Baker; Stanley J Radio
Journal:  J Pathol Inform       Date:  2015-07-28

10.  Comparison of the diagnostic utility of digital pathology systems for telemicrobiology.

Authors:  Daniel D Rhoads; Nadia F Habib-Bein; Rahman S Hariri; Douglas J Hartman; Sara E Monaco; Andrew Lesniak; Jon Duboy; Mohamed El-Sayed Salama; Liron Pantanowitz
Journal:  J Pathol Inform       Date:  2016-03-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.