Abstract

OBJECTIVES: To describe three steps: (1) the initial Veress pressure (VIP-Pressure), (2) transient high-pressure pneumoperitoneum (HIP-Entry) prior to trocar/cannula insertion, and (3) visual entry with a trocarless cannula during closed laparoscopic entry, which may reduce major injuries.
DESIGN: Prospective observational cohort study (Canadian Task Force Classification II-2).
SETTING: University-affiliated teaching hospital.
INTERVENTIONS: VIP-Pressure. During laparoscopic entry, the initial VIP pressure was measured and correlated against the body habitus and parity of 365 consecutive women. HIP-Entry was performed in 2,498 consecutive cases. In 100 women, the CO(2) volume, heart rate, blood pressure, oxygen saturation, and pulmonary compliance were recorded at pressures of 10, 15, 20, 25, and 30 mmHg. Visual entry with a trocarless blunt cannula was performed in 776 women. The cannula, housing a 0 degrees laparoscope, was rotated clockwise applying minimal downward force. MEASUREMENTS AND
RESULTS: VIP-Pressure. Pneumoperitoneum was established after one, two or three Veress needle attempts at the umbilicus in 82.4%, 10.9%, and 4.0% of women, respectively. In seven (2.2%), pneumoperitoneum was established at the left upper quadrant (LUQ) during the fourth attempt, and in two (0.6%) entry was abandoned. Median initial Veress pressure was 4 mmHg (range 2-10 mmHg). The VIP pressure correlated positively with women's weight (r = 0.518, p < 0.001) and body mass index (BMI) (r=0.545, p<0.001), and negatively with parity (r= -0.179, p<0.001). HIP-Entry. The abdomen was insufflated to 25-30 mmHg prior to primary trocar/cannula insertion. There were no changes in cardiovascular parameters between 15 and 30 mmHg. A 21% decrease in pulmonary compliance from 15 to 30 mmHg was of no clinical significance. No injury has been experienced with the visual cannula in 776 cases.
CONCLUSIONS: (1) A VIP-Pressure (<10 mmHg) indicates intraperitoneal placement of the Veress needle. (2) The use of transient HIP-Entry does not adversely affect cardiopulmonary function in healthy women. (3) Visual cannula offers an additional step towards safer entry.

Entities:  

Mesh:

Year:  2008        PMID: 18626703     DOI: 10.1007/s00464-008-0060-4

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  32 in total

Review 1.  Litigation of laparoscopic major vessel injuries in Canada.

Authors:  G A Vilos
Journal:  J Am Assoc Gynecol Laparosc       Date:  2000-11

Review 2.  Complications associated with optical-access laparoscopic trocars.

Authors:  Howard T Sharp; Mark K Dodson; Michael L Draper; Daren A Watts; Raymond C Doucette; William W Hurd
Journal:  Obstet Gynecol       Date:  2002-04       Impact factor: 7.661

Review 3.  Complications of laparoscopic surgery.

Authors:  Javier F Magrina
Journal:  Clin Obstet Gynecol       Date:  2002-06       Impact factor: 2.190

4.  Trocar injuries in laparoscopic surgery.

Authors:  S Bhoyrul; M A Vierra; C R Nezhat; T M Krummel; L W Way
Journal:  J Am Coll Surg       Date:  2001-06       Impact factor: 6.113

5.  Three spectra of laparoscopic entry access injuries.

Authors:  J G Chandler; S L Corson; L W Way
Journal:  J Am Coll Surg       Date:  2001-04       Impact factor: 6.113

6.  Safe entry techniques during laparoscopy: left upper quadrant entry using the ninth intercostal space--a review of 918 procedures.

Authors:  Neena Agarwala; C Y Liu
Journal:  J Minim Invasive Gynecol       Date:  2005 Jan-Feb       Impact factor: 4.137

7.  Survey of laparoscopic entry injuries provoking litigation.

Authors:  S L Corson; J G Chandler; L W Way
Journal:  J Am Assoc Gynecol Laparosc       Date:  2001-08

8.  Left upper quadrant approach in gynecologic laparoscopic surgery using reusable instruments.

Authors:  K W Lam; T C Pun
Journal:  J Am Assoc Gynecol Laparosc       Date:  2002-05

9.  Laparoscopy without trocars.

Authors:  A M Ternamian
Journal:  Surg Endosc       Date:  1997-08       Impact factor: 4.584

Review 10.  Trocar-associated injuries and fatalities: an analysis of 1399 reports to the FDA.

Authors:  Janie Fuller; Binita S Ashar; Julia Carey-Corrado
Journal:  J Minim Invasive Gynecol       Date:  2005 Jul-Aug       Impact factor: 4.137

View more
  6 in total

Review 1.  Abdominal anatomy in the context of port placement and trocars.

Authors:  Ibrahim Alkatout; Liselotte Mettler; Nicolai Maass; Günter-Karl Noé; Mohamed Elessawy
Journal:  J Turk Ger Gynecol Assoc       Date:  2015-11-02

Review 2.  Trocar Injuries in Laparoscopy: Techniques, Tools, and Means for Prevention. A Systematic Review of the Literature.

Authors:  Bram Cornette; Frederik Berrevoet
Journal:  World J Surg       Date:  2016-10       Impact factor: 3.352

3.  Routine blood group and antibody screening prior to emergency laparoscopy.

Authors:  J Barrett-Lee; J Vatish; M Vazirian-Zadeh; P Waterland
Journal:  Ann R Coll Surg Engl       Date:  2018-02-27       Impact factor: 1.891

4.  Laparoscopic management of a large torted ovarian cyst in an adolescent virgin: a case report.

Authors:  Mohamed Sabry; Abdou S Ait Allah; Eman Roshdy; Ayman Al-Hendy
Journal:  Int J Womens Health       Date:  2012-05-15

Review 5.  Complications of Laparoscopy in Connection with Entry Techniques.

Authors:  Ibrahim Alkatout
Journal:  J Gynecol Surg       Date:  2017-06-01

6.  A novel abdominal wall entry suction device to increase Veress needle safety: A prospective cohort pilot study.

Authors:  Jean H T Daemen; Laura N Deden; Anneline van den Ende; Milan E J Pijl; Cornelis H Slump; Frits J Berends; Edo O Aarts
Journal:  Ann Med Surg (Lond)       Date:  2019-10-07
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.