Literature DB >> 1862403

Change of disc height, radial disc bulge, and intradiscal pressure from discectomy. An in vitro investigation on human lumbar discs.

P Brinckmann1, H Grootenboer.   

Abstract

Partial discectomy was done in vitro on 15 human lumbar discs from donors 20-40 years of age. The change of disc height, radial disc bulge, and intradiscal pressure was measured in relation to the mass of central disc tissue excised. Disc height decreases and radial disc bulge increases approximately in proportion with the mass of the tissue excised. At the same time, intradiscal pressure decreases. On average, removal of 1 g of disc tissue results in a height decrease of 0.8 mm and a radial bulge increase of 0.2 mm. Removal of 3 g of central disc tissue lowers the intradiscal pressure to approximately 40% of its initial value. A mechanical model is presented which explains the observed relation between the volume of material removed and the subsequent change of height, bulge, and pressure. The experimental results and the model provide insight into the rationale of disc pressurization. A high intradiscal pressure is a prerequisite for the mechanical function of the disc under physiologic conditions.

Entities:  

Mesh:

Year:  1991        PMID: 1862403     DOI: 10.1097/00007632-199106000-00008

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  49 in total

1.  Replacing the nucleus pulposus of the intervertebral disk: prediction of suitable properties of a replacement material using finite element analysis.

Authors:  J R Meakin
Journal:  J Mater Sci Mater Med       Date:  2001-03       Impact factor: 3.896

2.  A prospective morphological study of facet joint integrity following intervertebral disc replacement with the CHARITE Artificial Disc.

Authors:  Hans Trouillier; P Kern; H J Refior; M Müller-Gerbl
Journal:  Eur Spine J       Date:  2005-09-07       Impact factor: 3.134

3.  Is a collagen scaffold for a tissue engineered nucleus replacement capable of restoring disc height and stability in an animal model?

Authors:  Hans-Joachim Wilke; Frank Heuer; Cornelia Neidlinger-Wilke; Lutz Claes
Journal:  Eur Spine J       Date:  2006-07-26       Impact factor: 3.134

4.  Effect of bilateral facetectomy of thoracolumbar spine T11-L1 on spinal stability.

Authors:  Tian-Xia Qiu; Ee-Chon Teo; Qing-Hang Zhang
Journal:  Med Biol Eng Comput       Date:  2006-04-05       Impact factor: 2.602

5.  Nucleotomy reduces the effects of cyclic compressive loading with unloaded recovery on human intervertebral discs.

Authors:  Brent L Showalter; Neil R Malhotra; Edward J Vresilovic; Dawn M Elliott
Journal:  J Biomech       Date:  2014-06-06       Impact factor: 2.712

6.  Intradiscal pressure depends on recent loading and correlates with disc height and compressive stiffness.

Authors:  Pieter-Paul A Vergroesen; Albert J van der Veen; Barend J van Royen; Idsart Kingma; Theo H Smit
Journal:  Eur Spine J       Date:  2014-07-17       Impact factor: 3.134

7.  Biomechanical changes of the lumbar intervertebral disc after automated and nonautomated percutaneous discectomy: an in vitro investigation.

Authors:  W H Castro; J Jerosch; J Rondhuis; H Halm; P Brinckmann
Journal:  Eur Spine J       Date:  1992-09       Impact factor: 3.134

8.  Abnormal stress concentrations in lumbar intervertebral discs following damage to the vertebral bodies: a cause of disc failure?

Authors:  M A Adams; D S McNally; J Wagstaff; A E Goodship
Journal:  Eur Spine J       Date:  1993-03       Impact factor: 3.134

9.  Vertebroplasty and Kyphoplasty Can Restore Normal Spine Mechanics following Osteoporotic Vertebral Fracture.

Authors:  Jin Luo; Michael A Adams; Patricia Dolan
Journal:  J Osteoporos       Date:  2010-06-20

10.  Biomechanical testing of a polymer-based biomaterial for the restoration of spinal stability after nucleotomy.

Authors:  Aldemar A Hegewald; Sven Knecht; Daniel Baumgartner; Hans Gerber; Michaela Endres; Christian Kaps; Edgar Stüssi; Claudius Thomé
Journal:  J Orthop Surg Res       Date:  2009-07-15       Impact factor: 2.359