Literature DB >> 18622793

Accuracy assessment of CT-based outer surface femur meshes.

F Gelaude1, J Vander Sloten, B Lauwers.   

Abstract

OBJECTIVES: Computer-aided bone surgery planning and implant design applications require accurate and compact representations of the patient's bone. The accuracy of bone segmentation from medical images has been studied extensively, with each study using a specific ground truth and a specific type and number of accuracy measurements. However, for convenience and practical reasons these three specifications have always been limited. The goal of this study is to thoroughly assess the absolute 3D accuracy of CT-based bone outer surface meshes, using femora as the examples.
MATERIALS AND METHODS: Using dense and very accurate optical surface scans of 15 dried femora as an absolute ground truth, this paper reports on the absolute 3D geometric accuracy of triangulated bone outer surface meshes, which were segmented from the CT scans of the corresponding formalin-fixed intact cadaver specimens using the author's previously presented contour-based segmentation algorithm on the one hand, and the commercially available Mimics(R) software (Materialise N.V., Leuven, Belgium) on the other. The study incorporates the effect of soft tissue presence on hard tissue segmentation and simultaneously reveals the accuracy shift introduced as a result of boiling the cadaver bones by processing extra CT scans of the dried bones.
RESULTS: The presented study demonstrates that, when using the optimal parameter settings for the respective segmentation procedures, sub-voxel mesh accuracies can be attained. Compact surface representations of femora can be generated with mean absolute accuracies of up to one fifth of the voxel size and Root Mean Square (RMS) error of half the voxel size.
CONCLUSIONS: The 3D accuracy of the contour-based segmentation previously presented by the author makes it most suitable for generating outer bone surface meshes for use in the aforementioned applications. The optimal parameter settings for this segmentation procedure have been identified. For the Mimics bone surface meshes, a single, but excellent, pre-defined set of parameters was identified.

Entities:  

Mesh:

Year:  2008        PMID: 18622793     DOI: 10.3109/10929080802195783

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  23 in total

1.  Morphology of insertion sites on patellar side of medial patellofemoral ligament.

Authors:  Shuhei Kikuchi; Goro Tajima; Jun Yan; Youichi Kamei; Moritaka Maruyama; Atsushi Sugawara; Kotaro Fujino; Sanjuro Takeda; Minoru Doita
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-01-07       Impact factor: 4.342

2.  Three-dimensional biplanar radiography as a new means of accessing femoral version: a comparitive study of EOS three-dimensional radiography versus computed tomography.

Authors:  M Lucius Pomerantz; Diana Glaser; Josh Doan; Sita Kumar; Eric W Edmonds
Journal:  Skeletal Radiol       Date:  2014-10-17       Impact factor: 2.199

3.  Three-dimensional finite element modeling of a maxillary premolar tooth based on the micro-CT scanning: a detailed description.

Authors:  Zheng Huang; Zhi Chen
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2013-10-20

4.  Morphology of the femoral insertion site of the medial patellofemoral ligament.

Authors:  Kotaro Fujino; Goro Tajima; Jun Yan; Youichi Kamei; Moritaka Maruyama; Sanjuro Takeda; Shuhei Kikuchi; Tadashi Shimamura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-12-03       Impact factor: 4.342

5.  How do CAD models compare with reverse engineered manufactured components for use in wear analysis?

Authors:  Matthew G Teeter; Douglas D R Naudie; Robert B Bourne; David W Holdsworth
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

Review 6.  Measuring and Establishing the Accuracy and Reproducibility of 3D Printed Medical Models.

Authors:  Elizabeth George; Peter Liacouras; Frank J Rybicki; Dimitrios Mitsouras
Journal:  Radiographics       Date:  2017-08-11       Impact factor: 5.333

7.  Morphology of the femoral insertion of the lateral collateral ligament and popliteus tendon.

Authors:  Sanjuro Takeda; Goro Tajima; Kotaro Fujino; Jun Yan; Youichi Kamei; Moritaka Maruyama; Shuhei Kikuchi; Minoru Doita
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-05-18       Impact factor: 4.342

8.  Morphology of the fibular insertion of the posterolateral corner and biceps femoris tendon.

Authors:  Hirotaka Takahashi; Goro Tajima; Shuhei Kikuchi; Jun Yan; Yoichi Kamei; Moritaka Maruyama; Atsushi Sugawara; Takaaki Saigo; Minoru Doita
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-09-12       Impact factor: 4.342

Review 9.  Three-dimensional reconstructions in spine and screw trajectory simulation on 3D digital images: a step by step approach by using Mimics software.

Authors:  Dong Chen; Chun-Hui Chen; Li Tang; Kai Wang; Yu-Zhe Li; Kevin Phan; Ai-Min Wu
Journal:  J Spine Surg       Date:  2017-12

10.  Current Total Knee Designs: Does Baseplate Roughness or Locking Mechanism Design Affect Polyethylene Backside Wear?

Authors:  Zachary W Sisko; Matthew G Teeter; Brent A Lanting; James L Howard; Richard W McCalden; Douglas D Naudie; Steven J MacDonald; Edward M Vasarhelyi
Journal:  Clin Orthop Relat Res       Date:  2017-09-13       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.