Literature DB >> 18617806

A method to obtain mean organ doses in a RANDO phantom.

Ernest M Scalzetti1, Walter Huda, Shashank Bhatt, Kent M Ogden.   

Abstract

A quantitative method of obtaining average organ dose from point measurements made in the male RANDO phantom is described for 24 compact organs of interest in patient dosimetry. A three-dimensional Cartesian coordinate system was created by considering each of the 36 RANDO phantom sections as the z coordinate, and using a rectangular frame to assign x and y coordinates relative to the center of each section. Anatomical atlases and clinical experience were used to identify the location and extent of each organ and tissue in the RANDO phantom. This proposed scheme is comparable to one used in a commercial phantom and offers investigators a comprehensive protocol for obtaining mean organ doses in the RANDO phantom.

Entities:  

Mesh:

Year:  2008        PMID: 18617806     DOI: 10.1097/01.HP.0000310997.09116.e3

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  7 in total

1.  Organ and effective dose reduction in adult chest CT using abdominal lead shielding.

Authors:  G R Iball; D S Brettle
Journal:  Br J Radiol       Date:  2011-11       Impact factor: 3.039

2.  In-patient to isocenter KERMA ratios in CT.

Authors:  Walter Huda; Kent M Ogden; Robert L Lavallee; Marsha L Roskopf; Ernest M Scalzetti
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

3.  A comparison of radiation exposure between diagnostic CTA and DSA examinations of cerebral and cervicocerebral vessels.

Authors:  A-L Manninen; J-M Isokangas; A Karttunen; T Siniluoto; M T Nieminen
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-14       Impact factor: 3.825

4.  Head and neck effective dose and quantitative assessment of image quality: a study to compare cone beam CT and multislice spiral CT.

Authors:  Cosimo Nardi; Cinzia Talamonti; Stefania Pallotta; Paola Saletti; Linda Calistri; Cesare Cordopatri; Stefano Colagrande
Journal:  Dentomaxillofac Radiol       Date:  2017-06-20       Impact factor: 2.419

5.  Secondary cancer risk from modern external-beam radiotherapy of prostate cancer patients: Impact of fractionation and dose distribution.

Authors:  Chomporn Sitathanee; Puangpen Tangboonduangjit; Mantana Dhanachai; Sawanee Suntiwong; Pornpan Yongvithisatid; Sukanya Rutchantuk; Pimolpun Changkaew; Rattana Watjiranon; Suphalak Khachonkham; Vipa Boonkitticharoen
Journal:  J Radiat Res       Date:  2021-07-10       Impact factor: 2.724

6.  Skin Dosimetry with EBT3 Radiochromic Film in Radiotherapy of Parotid Cancer.

Authors:  Mohammad Taghi Bahreyni Toossi; Mahdi Ghorbani; Farideh Khorshidi; Mohammad Mohammadi; Nastaran Mohamadian; Fateme Akbari; Mahdie Dayani
Journal:  J Biomed Phys Eng       Date:  2021-10-01

7.  Evaluation of patient organ doses from kilovoltage cone-beam CT imaging in radiation therapy.

Authors:  Alper Özseven; Bahar Dirican
Journal:  Rep Pract Oncol Radiother       Date:  2021-04-14
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.