| Literature DB >> 18617364 |
Kenji Kawate1, Yutaka Ohneda, Tetsuji Ohmura, Hiroshi Yajima, Kazuya Sugimoto, Yoshinori Takakura.
Abstract
We investigated 55 hips of 53 patients with dysplastic hips. Individual computed tomography data were used in the manufacturing of cementless custom-made stems made of Ti-6Al-4V. The proximal one third was coated using porous coating covered with hydroxyapatite coating. The average age at surgery was 60 years and the average follow-up was 7 years. Five patients (9%) complained of postoperative thigh pain. According to Engh's radiologic classification system, there was bone-ingrown fixation in all hips. The cortical index and canal flare index were lower, and stem diameter was greater in the 11 hips (20%) with severe stress shielding than in the remaining 44 hips. Although the results obtained with this custom-made stem system for dysplastic hips were excellent, stress shielding is still an issue.Entities:
Mesh:
Substances:
Year: 2008 PMID: 18617364 DOI: 10.1016/j.arth.2007.12.021
Source DB: PubMed Journal: J Arthroplasty ISSN: 0883-5403 Impact factor: 4.757