Literature DB >> 18613700

Stripping analysis of nanomolar perchlorate in drinking water with a voltammetric ion-selective electrode based on thin-layer liquid membrane.

Yushin Kim1, Shigeru Amemiya.   

Abstract

A highly sensitive analytical method is required for the assessment of nanomolar perchlorate contamination in drinking water as an emerging environmental problem. We developed the novel approach based on a voltammetric ion-selective electrode to enable the electrochemical detection of "redox-inactive" perchlorate at a nanomolar level without its electrolysis. The perchlorate-selective electrode is based on the submicrometer-thick plasticized poly(vinyl chloride) membrane spin-coated on the poly(3-octylthiophene)-modified gold electrode. The liquid membrane serves as the first thin-layer cell for ion-transfer stripping voltammetry to give low detection limits of 0.2-0.5 nM perchlorate in deionized water, commercial bottled water, and tap water under a rotating electrode configuration. The detection limits are not only much lower than the action limit (approximately 246 nM) set by the U.S. Environmental Protection Agency but also are comparable to the detection limits of the most sensitive analytical methods for detecting perchlorate, that is, ion chromatography coupled with a suppressed conductivity detector (0.55 nM) or electrospray ionization mass spectrometry (0.20-0.25 nM). The mass transfer of perchlorate in the thin-layer liquid membrane and aqueous sample as well as its transfer at the interface between the two phases were studied experimentally and theoretically to achieve the low detection limits. The advantages of ion-transfer stripping voltammetry with a thin-layer liquid membrane against traditional ion-selective potentiometry are demonstrated in terms of a detection limit, a response time, and selectivity.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18613700     DOI: 10.1021/ac8008687

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

Review 1.  Electrochemical sensors.

Authors:  Benjamin J Privett; Jae Ho Shin; Mark H Schoenfisch
Journal:  Anal Chem       Date:  2010-06-15       Impact factor: 6.986

2.  Ion-selective permeability of an ultrathin nanoporous silicon membrane as probed by scanning electrochemical microscopy using micropipet-supported ITIES tips.

Authors:  Ryoichi Ishimatsu; Jiyeon Kim; Ping Jing; Christopher C Striemer; David Z Fang; Philippe M Fauchet; James L McGrath; Shigeru Amemiya
Journal:  Anal Chem       Date:  2010-09-01       Impact factor: 6.986

3.  High lipophilicity of perfluoroalkyl carboxylate and sulfonate: implications for their membrane permeability.

Authors:  Ping Jing; Patrick J Rodgers; Shigeru Amemiya
Journal:  J Am Chem Soc       Date:  2009-02-18       Impact factor: 15.419

4.  Electrochemical Sensing and Imaging Based on Ion Transfer at Liquid/Liquid Interfaces.

Authors:  Shigeru Amemiya; Jiyeon Kim; Anahita Izadyar; Benjamin Kabagambe; Mei Shen; Ryoichi Ishimatsu
Journal:  Electrochim Acta       Date:  2013-11-01       Impact factor: 6.901

5.  High-temperature potentiometry: modulated response of ion-selective electrodes during heat pulses.

Authors:  Karin Y Chumbimuni-Torres; Chongdee Thammakhet; Michal Galik; Percy Calvo-Marzal; Jie Wu; Eric Bakker; Gerd-Uwe Flechsig; Joseph Wang
Journal:  Anal Chem       Date:  2009-12-15       Impact factor: 6.986

6.  Voltammetric Mechanism of Multiion Detection with Thin Ionophore-Based Polymeric Membrane.

Authors:  Peter J Greenawalt; Shigeru Amemiya
Journal:  Anal Chem       Date:  2016-05-09       Impact factor: 6.986

7.  Functionalization of PET Track-Etched Membranes by UV-Induced Graft (co)Polymerization for Detection of Heavy Metal Ions in Water.

Authors:  Maxim V Zdorovets; Ilya V Korolkov; Arman B Yeszhanov; Yevgeniy G Gorin
Journal:  Polymers (Basel)       Date:  2019-11-13       Impact factor: 4.329

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.