Literature DB >> 18601596

Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories.

Giuseppe Lippi1, Norbert Blanckaert, Pierangelo Bonini, Sol Green, Steve Kitchen, Vladimir Palicka, Anne J Vassault, Mario Plebani.   

Abstract

Prevention of medical errors is a major goal of healthcare, though healthcare workers themselves have not yet fully accepted or implemented reliable models of system error, and neither has the public. While there is widespread perception that most medical errors arise from an inappropriate or delayed clinical management, the issue of laboratory errors is receiving a great deal of attention due to their impact on the quality and efficiency of laboratory performances and patient safety. Haemolytic specimens are a frequent occurrence in clinical laboratories, and prevalence can be as high as 3.3% of all of the routine samples, accounting for up to 40%-70% of all unsuitable specimens identified, nearly five times higher than other causes, such as insufficient, incorrect and clotted samples. This article focuses on this challenging issue, providing an overview on prevalence and leading causes of in vivo and in vitro haemolysis, and tentative guidelines on identification and management of haemolytic samples in clinical laboratories. This strategy includes continuous education of healthcare personnel, systematic detection/quantification of haemolysis in any sample, immediate clinicians warning on the probability of in vivo haemolysis, registration of non-conformity, completing of tests unaffected by haemolysis and request of a second specimen for those potentially affected.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18601596     DOI: 10.1515/CCLM.2008.170

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  63 in total

1.  Pseudohyperkalemia without reported haemolysis in a patient with chronic lymphocytic leukaemia.

Authors:  James S Chan; Stacy L Baker; Aaron W Bernard
Journal:  BMJ Case Rep       Date:  2012-01-10

Review 2.  Pre-analytic variability in cardiovascular biomarker testing.

Authors:  Roberto Cemin; Massimo Daves
Journal:  J Thorac Dis       Date:  2015-10       Impact factor: 2.895

3.  Types and frequency of preanalytical errors in haematology lab.

Authors:  Shashi Upreti; Sanjay Upreti; Rani Bansal; Nadia Jeelani; Vinay Bharat
Journal:  J Clin Diagn Res       Date:  2013-11-10

4.  Maximizing peptide identification events in proteomic workflows using data-dependent acquisition (DDA).

Authors:  Nicholas W Bateman; Scott P Goulding; Nicholas J Shulman; Avinash K Gadok; Karen K Szumlinski; Michael J MacCoss; Christine C Wu
Journal:  Mol Cell Proteomics       Date:  2013-07-02       Impact factor: 5.911

5.  Preanalytical stability of adrenocorticotropic hormone depends on both time to centrifugation and temperature.

Authors:  Zhi-Qi Wu; Hua-Guo Xu
Journal:  J Clin Lab Anal       Date:  2016-10-13       Impact factor: 2.352

Review 6.  Effectiveness of practices to reduce blood sample hemolysis in EDs: a laboratory medicine best practices systematic review and meta-analysis.

Authors:  Nicholas J Heyer; James H Derzon; Linda Winges; Colleen Shaw; Diana Mass; Susan R Snyder; Paul Epner; James H Nichols; Julie A Gayken; Dennis Ernst; Edward B Liebow
Journal:  Clin Biochem       Date:  2012-09       Impact factor: 3.281

7.  Targeting Rejection: Analysis of Specimen Acceptability and Rejection, and Framework for Identifying Interventions in a Single Tertiary Healthcare Facility.

Authors:  Lisa Rooper; Jamal Carter; John Hargrove; Sheri Hoffmann; Stefan Riedel
Journal:  J Clin Lab Anal       Date:  2016-09-15       Impact factor: 2.352

8.  Hemolysis and IgA-antibodies against tissue transglutaminase: When are antibody test results no longer reliable?

Authors:  Johannes Wolf; Norman Haendel; Johannes Remmler; Carl Elias Kutzner; Thorsten Kaiser; Thomas Mothes
Journal:  J Clin Lab Anal       Date:  2017-11-23       Impact factor: 2.352

9.  Errors in the Extra-Analytical Phases of Clinical Chemistry Laboratory Testing.

Authors:  Annalise E Zemlin
Journal:  Indian J Clin Biochem       Date:  2017-05-05

10.  Development of a Novel Quality Improvement Indicator Based on the Hemolysis Index.

Authors:  Eun Jin Lee; Miyoung Kim; Han Sung Kim; Min Jeong Park; Young Kyung Lee; Hee Jung Kang
Journal:  Ann Lab Med       Date:  2016-11       Impact factor: 3.464

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.