Literature DB >> 18599401

System calibration and statistical image reconstruction for ultra-high resolution stationary pinhole SPECT.

Frans van der Have1, Brendan Vastenhouw, Mart Rentmeester, Freek J Beekman.   

Abstract

For multipinhole single-photon emission computed tomography (SPECT), iterative reconstruction algorithms are preferred over analytical methods, because of the often complex multipinhole geometries and the ability of iterative algorithms to compensate for effects like spatially variant sensitivity and resolution. Ideally, such compensation methods are based on accurate knowledge of the position-dependent point spread functions (PSFs) specifying the response of the detectors to a point source at every position in the instrument. This paper describes a method for model-based generation of complete PSF lookup tables from a limited number of point-source measurements for stationary SPECT systems and its application to a submillimeter resolution stationary small-animal SPECT system containing 75 pinholes (U-SPECT-I). The method is based on the generalization over the entire object to be reconstructed, of a small number of properties of point-source responses which are obtained at a limited number of measurement positions. The full shape of measured point-source responses can almost be preserved in newly created PSF tables. We show that these PSFs can be used to obtain high-resolution SPECT reconstructions: the reconstructed resolutions judged by rod visibility in a micro-Derenzo phantom are 0.45 mm with 0.6-mm pinholes and below 0.35 mm with 0.3-mm pinholes. In addition, we show that different approximations, such as truncating the PSF kernel, with significant reduction of reconstruction time, can still lead to acceptable reconstructions.

Entities:  

Mesh:

Year:  2008        PMID: 18599401     DOI: 10.1109/TMI.2008.924644

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  19 in total

1.  Small-animal molecular imaging methods.

Authors:  Robert A de Kemp; Frederick H Epstein; Ciprian Catana; Benjamin M W Tsui; Erik L Ritman
Journal:  J Nucl Med       Date:  2010-05-01       Impact factor: 10.057

2.  A SPECT imager with synthetic collimation.

Authors:  Ronan J Havelin; Brian W Miller; Harrison H Barrett; Lars R Furenlid; J M Murphy; Mark J Foley
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-08-25

3.  A residual correction method for high-resolution PET reconstruction with application to on-the-fly Monte Carlo based model of positron range.

Authors:  Lin Fu; Jinyi Qi
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

4.  In vivo Biodistribution of Radiolabeled Acoustic Protein Nanostructures.

Authors:  Johann Le Floc'h; Aimen Zlitni; Holly A Bilton; Melissa Yin; Arash Farhadi; Nancy R Janzen; Mikhail G Shapiro; John F Valliant; F Stuart Foster
Journal:  Mol Imaging Biol       Date:  2018-04       Impact factor: 3.488

5.  Absolute quantitative total-body small-animal SPECT with focusing pinholes.

Authors:  Chao Wu; Frans van der Have; Brendan Vastenhouw; Rudi A J O Dierckx; Anne M J Paans; Freek J Beekman
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-06-25       Impact factor: 9.236

6.  Performance evaluation of small-animal multipinhole μSPECT scanners for mouse imaging.

Authors:  Steven Deleye; Roel Van Holen; Jeroen Verhaeghe; Stefaan Vandenberghe; Sigrid Stroobants; Steven Staelens
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-01-24       Impact factor: 9.236

Review 7.  Recent advances in small-animal cardiovascular imaging.

Authors:  Benjamin M W Tsui; Dara L Kraitchman
Journal:  J Nucl Med       Date:  2009-04-16       Impact factor: 10.057

8.  A System Calibration and Fast Iterative Reconstruction Method for Next-Generation SPECT Imagers.

Authors:  Brian W Miller; Roel Van Holen; Harrison H Barrett; Lars R Furenlid
Journal:  IEEE Trans Nucl Sci       Date:  2012-10       Impact factor: 1.679

9.  A System Calibration and Fast Iterative Reconstruction Method for Next-Generation SPECT Imagers.

Authors:  Brian W Miller; Roel Van Holen; Harrison H Barrett; Lars R Furenlid
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2011-10-23

10.  Joint Optimization of Collimator and Reconstruction Parameters in X-Ray Fluorescence Computed Tomography Using Analytical Point Spread Function and Model Observer.

Authors:  Hsin Wu Tseng; Srinivasan Vedantham; Sang Hyun Cho; Andrew Karellas
Journal:  IEEE Trans Biomed Eng       Date:  2019-12-30       Impact factor: 4.538

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.