Literature DB >> 18599397

Computational analysis and improvement of SIRT.

Jens Gregor1, Thomas Benson.   

Abstract

Iterative X-ray computed tomography (CT) algorithms have the potential for producing high-quality images but are computationally very demanding, especially when applied to high-resolution problems. Focusing on simultaneous iterative reconstruction technique (SIRT), we provide an eigenvalue based scheme for automatically determining a near-optimal value of the relaxation parameter. This accelerates the convergence rate of SIRT to the point where only half the number of iterations normally required is needed. We also modify the way SIRT uses preconditioning to solve a weighted least squares problem. The resulting algorithm, which we call PSIRT, is associated with a smaller memory footprint and calls for less data to be communicated in a distributed-memory implementation. Experimental residual norm and timing results are provided based on cone-beam micro-CT mouse data, including for an ordered subsets study.

Entities:  

Mesh:

Year:  2008        PMID: 18599397     DOI: 10.1109/TMI.2008.923696

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  16 in total

1.  Comparison of SIRT and SQS for Regularized Weighted Least Squares Image Reconstruction.

Authors:  Jens Gregor; Jeffrey A Fessler
Journal:  IEEE Trans Comput Imaging       Date:  2015-06-05

2.  High resolution 3D visualization of the spinal cord in a post-mortem murine model.

Authors:  Inna Bukreeva; Victor Asadchikov; Alexey Buzmakov; Marina Chukalina; Anastasya Ingacheva; Nikolay A Korolev; Alberto Bravin; Alberto Mittone; Gabriele E M Biella; Alejandra Sierra; Francesco Brun; Lorenzo Massimi; Michela Fratini; Alessia Cedola
Journal:  Biomed Opt Express       Date:  2020-03-27       Impact factor: 3.732

3.  Significance of the spectral correction of photon counting detector response in material classification from spectral x-ray CT.

Authors:  Doniyor Jumanazarov; Jakeoung Koo; Henning F Poulsen; Ulrik L Olsen; Mihai Iovea
Journal:  J Med Imaging (Bellingham)       Date:  2022-06-30

4.  The Influence of X-Ray Computed Tomography Acquisition Parameters on Image Quality and Probability of Detection of Additive Manufacturing Defects.

Authors:  Felix H Kim; Adam L Pintar; Shawn P Moylan; Edward J Garboczi
Journal:  J Manuf Sci Eng       Date:  2019-11       Impact factor: 3.033

5.  Deep denoising for multi-dimensional synchrotron X-ray tomography without high-quality reference data.

Authors:  Allard A Hendriksen; Minna Bührer; Laura Leone; Marco Merlini; Nicola Vigano; Daniël M Pelt; Federica Marone; Marco di Michiel; K Joost Batenburg
Journal:  Sci Rep       Date:  2021-06-04       Impact factor: 4.379

6.  CT brush and CancerZap!: two video games for computed tomography dose minimization.

Authors:  Graham Alvare; Richard Gordon
Journal:  Theor Biol Med Model       Date:  2015-05-12       Impact factor: 2.432

7.  A multiresolution approach to discrete tomography using DART.

Authors:  Andrei Dabravolski; Kees Joost Batenburg; Jan Sijbers
Journal:  PLoS One       Date:  2014-09-05       Impact factor: 3.240

8.  A novel method for dendrochronology of large historical wooden objects using line trajectory X-ray tomography.

Authors:  Francien G Bossema; Marta Domínguez-Delmás; Willem Jan Palenstijn; Alexander Kostenko; Jan Dorscheid; Sophia Bethany Coban; Erma Hermens; K Joost Batenburg
Journal:  Sci Rep       Date:  2021-05-26       Impact factor: 4.379

9.  Radiation dose reduction of chest CT with iterative reconstruction in image space - Part I: studies on image quality using dual source CT.

Authors:  Hye Jeon Hwang; Joon Beom Seo; Jin Seong Lee; Jae-Woo Song; Song Soo Kim; Hyun Joo Lee; Chae Hun Lim
Journal:  Korean J Radiol       Date:  2012-10-12       Impact factor: 3.500

10.  Bone-induced streak artifact suppression in sparse-view CT image reconstruction.

Authors:  Seung Oh Jin; Jae Gon Kim; Soo Yeol Lee; Oh-Kyong Kwon
Journal:  Biomed Eng Online       Date:  2012-08-02       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.