Literature DB >> 18599285

Non-enzymatic glucose biosensor based on overoxidized polypyrrole nanofiber electrode modified with cobalt(II) phthalocyanine tetrasulfonate.

Levent Ozcan1, Yücel Sahin, Hayrettin Türk.   

Abstract

An enzymeless biosensor, based on electrodeposition of overoxidized polypyrrole nanofiber onto pencil graphite electrode and modified with cobalt(II) phthalocyanine tetrasulfonate (CoPcTS), was investigated in this study. CoPcTS showed electrocatalytic activity for the oxidation of glucose in alkaline solution. The electrochemical performance of the modified electrodes was investigated by differential pulse voltammetric (DPV) method. The resulting biosensor exhibited excellent performance for glucose determination with a wide linear range (0.25-20mM), a highly reproducible response (R.S.D. of 2.7%), low percentage of the interferences and long-term stability. The calculated detection limit was 0.1mM at 3sigma. In order to verify the reliability of the biosensor, it was applied to the determination of glucose in serum samples. The results were satisfactory and agreed closely with those measured in a hospital.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18599285     DOI: 10.1016/j.bios.2008.05.004

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  9 in total

1.  Electrochemical Preparation of a Molecularly Imprinted Polypyrrole-modified Pencil Graphite Electrode for Determination of Ascorbic Acid.

Authors:  Levent Özcan; Mutlu Sahin; Yücel Sahin
Journal:  Sensors (Basel)       Date:  2008-09-18       Impact factor: 3.576

2.  Voltammetric Behaviour of Sulfamethoxazole on Electropolymerized-Molecularly Imprinted Overoxidized Polypyrrole.

Authors:  Sabriye Perçin Ozkorucuklu; Yücel Sahin; Güleren Alsancak
Journal:  Sensors (Basel)       Date:  2008-12-18       Impact factor: 3.576

3.  Nanostructured biosensor using bioluminescence quenching technique for glucose detection.

Authors:  Longyan Chen; Longyi Chen; Michelle Dotzert; C W James Melling; Jin Zhang
Journal:  J Nanobiotechnology       Date:  2017-08-22       Impact factor: 10.435

Review 4.  Pencil Graphite Electrodes: A Versatile Tool in Electroanalysis.

Authors:  Iulia Gabriela David; Dana-Elena Popa; Mihaela Buleandra
Journal:  J Anal Methods Chem       Date:  2017-01-31       Impact factor: 2.193

Review 5.  Polymers and Plastics Modified Electrodes for Biosensors: A Review.

Authors:  Sonia Lanzalaco; Brenda G Molina
Journal:  Molecules       Date:  2020-05-24       Impact factor: 4.411

6.  Preparation and Characterization of Magnetic Polypyrrole Composite Microspheres Decorated with Copper (II) As A Sensing Platform for Electrochemical Detection of Carbamazepine.

Authors:  Azadeh Fatahi; Reihaneh Malakooti; Mohsen Shahlaei
Journal:  Iran J Pharm Res       Date:  2020       Impact factor: 1.696

7.  Reduced graphene oxide-supported methylene blue nanocomposite as a glucose oxidase-mimetic for electrochemical glucose sensing.

Authors:  Shaojun Yang; Daliang Liu; Qing Bo Meng; Shuyao Wu; Xi-Ming Song
Journal:  RSC Adv       Date:  2018-09-20       Impact factor: 3.361

8.  Nickel sulfide-incorporated sulfur-doped graphitic carbon nitride nanohybrid interface for non-enzymatic electrochemical sensing of glucose.

Authors:  S Vinoth; P Mary Rajaitha; A Venkadesh; K S Shalini Devi; S Radhakrishnan; A Pandikumar
Journal:  Nanoscale Adv       Date:  2020-07-30

9.  Cobalt Phthalocyanine-Ionic Liquid Composite Modified Electrodes for the Voltammetric Detection of DNA Hybridization Related to Hepatitis B Virus.

Authors:  Ece Yaralı; Arzum Erdem
Journal:  Micromachines (Basel)       Date:  2021-06-26       Impact factor: 2.891

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.