Literature DB >> 18595743

Biomechanical comparison of single-row arthroscopic rotator cuff repair technique versus transosseous repair technique.

Stephen L Tocci1, Robert Z Tashjian, Evan Leventhal, David B Spenciner, Andrew Green, Braden C Fleming.   

Abstract

This study determined the effect of tear size on gap formation of single-row simple-suture arthroscopic rotator cuff repair (ARCR) vs transosseous Mason-Allen suture open RCR (ORCR) in 13 pairs of human cadaveric shoulders. A massive tear was created in 6 pairs and a large tear in 7. Repairs were cyclically tested in low-load and high-load conditions, with no significant difference in gap formation. Under low-load, gapping was greater in massive tears. Under high-load, there was a trend toward increased gap with ARCR for large tears. All repairs of massive tears failed in high-load. Gapping was greater posteriorly in massive tears for both techniques. Gap formation of a modeled RCR depends upon the tear size. ARCR of larger tears may have higher failure rates than ORCR, and the posterior aspect appears to be the site of maximum gapping. Specific attention should be directed toward maximizing initial fixation of larger rotator cuff tears, especially at the posterior aspect.

Entities:  

Mesh:

Year:  2008        PMID: 18595743     DOI: 10.1016/j.jse.2008.02.016

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  6 in total

Review 1.  Single versus double-row repair of the rotator cuff: does double-row repair with improved anatomical and biomechanical characteristics lead to better clinical outcome?

Authors:  Stephan Pauly; Christian Gerhardt; Jianhai Chen; Markus Scheibel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-08-25       Impact factor: 4.342

2.  Arthroscopic transosseous rotator cuff repair: technical note, outcomes, and complications.

Authors:  Eric M Black; Albert Lin; Uma Srikumaran; Nitin Jain; Michael T Freehill
Journal:  Orthopedics       Date:  2015-05       Impact factor: 1.390

3.  The rotator cuff tear repair with a new arthroscopic transosseous system: the Sharc-FT(®).

Authors:  P Baudi; E Rasia Dani; G Campochiaro; M Rebuzzi; F Serafini; F Catani
Journal:  Musculoskelet Surg       Date:  2013-04-16

4.  Biological augmentation of rotator cuff repair using bFGF-loaded electrospun poly(lactide-co-glycolide) fibrous membranes.

Authors:  Song Zhao; Jingwen Zhao; Shikui Dong; Xiaoqiao Huangfu; Bin Li; Huilin Yang; Jinzhong Zhao; Wenguo Cui
Journal:  Int J Nanomedicine       Date:  2014-05-14

5.  Icariin Promotes Tendon-Bone Healing during Repair of Rotator Cuff Tears: A Biomechanical and Histological Study.

Authors:  Chenyi Ye; Wei Zhang; Shengdong Wang; Shuai Jiang; Yuanbin Yu; Erman Chen; Deting Xue; Jianzhong Chen; Rongxin He
Journal:  Int J Mol Sci       Date:  2016-10-25       Impact factor: 5.923

6.  A non-inferiority comparison of Delta Medical's PEEK Suture Anchor and Smith & Nephew's PEEK Suture Anchor in arthroscopic rotator cuff repair: a multicenter prospective single-blind randomized controlled clinical trial.

Authors:  Peng Gao; Hongtao Wang; Yongsheng Xu; Yanlin Li; Guofeng Cai; Yufeng Wu; Ziqi Huang; Qiang Li; Jing Wang
Journal:  Ann Transl Med       Date:  2021-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.