Literature DB >> 18594635

Accurate image reconstruction from few-view and limited-angle data in diffraction tomography.

Samuel J LaRoque1, Emil Y Sidky, Xiaochuan Pan.   

Abstract

We present a method for obtaining accurate image reconstruction from highly sparse data in diffraction tomography (DT). A practical need exists for reconstruction from few-view and limited-angle data, as this can greatly reduce required scan times in DT. Our method does this by minimizing the total variation (TV) of the estimated image, subject to the constraint that the Fourier transform of the estimated image matches the measured Fourier data samples. Using simulation studies, we show that the TV-minimization algorithm allows accurate reconstruction in a variety of few-view and limited-angle situations in DT. Accurate image reconstruction is obtained from far fewer data samples than are required by common algorithms such as the filtered-backpropagation algorithm. Overall our results indicate that the TV-minimization algorithm can be successfully applied to DT image reconstruction under a variety of scan configurations and data conditions of practical significance.

Entities:  

Mesh:

Year:  2008        PMID: 18594635      PMCID: PMC2834797          DOI: 10.1364/josaa.25.001772

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  5 in total

1.  An accurate iterative reconstruction algorithm for sparse objects: application to 3D blood vessel reconstruction from a limited number of projections.

Authors:  Meihua Li; Haiquan Yang; Hiroyuki Kudo
Journal:  Phys Med Biol       Date:  2002-08-07       Impact factor: 3.609

2.  Comparison of reconstruction algorithms for optical diffraction tomography.

Authors:  Pengyi Guo; Anthony J Devaney
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2005-11       Impact factor: 2.129

3.  Unified reconstruction theory for diffraction tomography, with consideration of noise control.

Authors:  X Pan
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  1998-09       Impact factor: 2.129

4.  Minimal-scan filtered backpropagation algorithms for diffraction tomography.

Authors:  X Pan; M A Anastasio
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  1999-12       Impact factor: 2.129

5.  A filtered backpropagation algorithm for diffraction tomography.

Authors:  A J Devaney
Journal:  Ultrason Imaging       Date:  1982-10       Impact factor: 1.578

  5 in total
  16 in total

1.  Compressed sensing based cone-beam computed tomography reconstruction with a first-order method.

Authors:  Kihwan Choi; Jing Wang; Lei Zhu; Tae-Suk Suh; Stephen Boyd; Lei Xing
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

2.  Selective-diffusion regularization for enhancement of microcalcifications in digital breast tomosynthesis reconstruction.

Authors:  Yao Lu; Heang-Ping Chan; Jun Wei; Lubomir M Hadjiiski
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

3.  An interprojection sensor fusion approach to estimate blocked projection signal in synchronized moving grid-based CBCT system.

Authors:  Hong Zhang; Lei Ren; Vic Kong; William Giles; You Zhang; Jian-Yue Jin
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

4.  Statistical iterative reconstruction to improve image quality for digital breast tomosynthesis.

Authors:  Shiyu Xu; Jianping Lu; Otto Zhou; Ying Chen
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

5.  Cone-beam breast computed tomography using ultra-fast image reconstruction with constrained, total-variation minimization for suppression of artifacts.

Authors:  Hsin Wu Tseng; Srinivasan Vedantham; Andrew Karellas
Journal:  Phys Med       Date:  2020-04-28       Impact factor: 2.685

6.  Volume-of-change cone-beam CT for image-guided surgery.

Authors:  Junghoon Lee; J Webster Stayman; Yoshito Otake; Sebastian Schafer; Wojciech Zbijewski; A Jay Khanna; Jerry L Prince; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2012-07-17       Impact factor: 3.609

7.  Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?

Authors:  Xiaochuan Pan; Emil Y Sidky; Michael Vannier
Journal:  Inverse Probl       Date:  2009-01-01       Impact factor: 2.407

8.  Technical Note: Iterative megavoltage CT (MVCT) reconstruction using block-matching 3D-transform (BM3D) regularization.

Authors:  Qihui Lyu; Chunlin Yang; Hao Gao; Yi Xue; Daniel O'Connor; Tianye Niu; Ke Sheng
Journal:  Med Phys       Date:  2018-04-30       Impact factor: 4.071

9.  Dynamic intensity-weighted region of interest imaging for conebeam CT.

Authors:  Erik Pearson; Xiaochuan Pan; Charles Pelizzari
Journal:  J Xray Sci Technol       Date:  2016-03-17       Impact factor: 1.535

10.  PWLS-PR: low-dose computed tomography image reconstruction using a patch-based regularization method based on the penalized weighted least squares total variation approach.

Authors:  Jing Fu; Fei Feng; Huimin Quan; Qian Wan; Zixiang Chen; Xin Liu; Hairong Zheng; Dong Liang; Guanxun Cheng; Zhanli Hu
Journal:  Quant Imaging Med Surg       Date:  2021-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.