Literature DB >> 18581504

Comparison of the USCOM ultrasound cardiac output monitor with pulmonary artery catheter thermodilution in patients undergoing liver transplantation.

Lai-Sze Grace Wong1, Boon-Hun Yong, Karl Kang Young, Lee-Sung Lau, King-Lik Cheng, Jeff Siu-Fan Man, Michael G Irwin.   

Abstract

The aim of the study was to compare the standard technique of cardiac output determination by pulmonary artery catheter thermodilution (PAC-TD) with a noninvasive ultrasound Doppler monitor (USCOM Pty., Ltd., Coffs Harbour, Australia) in surgery for liver transplantation. We wished to determine if the degree of accuracy would allow the ultrasound cardiac output monitor (USCOM) to be used as an alternative monitor in a clinical setting in which wide fluctuations in cardiac output could be expected. This was a prospective method comparison study, with 71 paired measurements obtained in 12 patients undergoing liver transplantation in a university teaching hospital. Bland-Altman analysis of the 2 techniques showed a bias of 0.39 L/minute, with the USCOM cardiac output lower compared with that of PAC-TD. The bias was small and did not vary with the magnitude of the cardiac output. The 95% limits of agreement were -1.47 and 2.25 L/minute. There was good repeatability for USCOM measurements, with a repeatability coefficient of 0.43 for USCOM versus 0.77 for PAC-TD. We conclude that USCOM is acceptable for the clinical determination of noninvasive cardiac output, particularly in situations in which tracking changes over time is more important than knowing the precise value. However, the utility of USCOM is limited by its inability to measure pulmonary artery pressure.

Entities:  

Mesh:

Year:  2008        PMID: 18581504     DOI: 10.1002/lt.21483

Source DB:  PubMed          Journal:  Liver Transpl        ISSN: 1527-6465            Impact factor:   5.799


  15 in total

1.  In vitro evaluation of an ultrasonic cardiac output monitoring (USCOM) device.

Authors:  Shaun D Gregory; Helena Cooney; Sara Diab; Chris Anstey; Ogilvie Thom; John F Fraser
Journal:  J Clin Monit Comput       Date:  2015-03-07       Impact factor: 2.502

Review 2.  [Meta-analyses on measurement precision of non-invasive hemodynamic monitoring technologies in adults].

Authors:  G Pestel; K Fukui; M Higashi; I Schmidtmann; C Werner
Journal:  Anaesthesist       Date:  2018-06       Impact factor: 1.041

3.  Ultrasound Assessment of the Change in Carotid Corrected Flow Time in Fluid Responsiveness in Undifferentiated Shock.

Authors:  Igor Barjaktarevic; William E Toppen; Scott Hu; Elizabeth Aquije Montoya; Stephanie Ong; Russell Buhr; Ian J David; Tisha Wang; Talayeh Rezayat; Steven Y Chang; David Elashoff; Daniela Markovic; David Berlin; Maxime Cannesson
Journal:  Crit Care Med       Date:  2018-11       Impact factor: 7.598

4.  Cardiac index measurements by transcutaneous Doppler ultrasound and transthoracic echocardiography in adult and pediatric emergency patients.

Authors:  H Bryant Nguyen; Daryl P Banta; Gail Stewart; Tommy Kim; Ramesh Bansal; James Anholm; William A Wittlake; Stephen W Corbett
Journal:  J Clin Monit Comput       Date:  2010-06-20       Impact factor: 2.502

5.  The resuscitation package in sepsis.

Authors:  Lee M Demertzis; Marin H Kollef
Journal:  Curr Infect Dis Rep       Date:  2010-09       Impact factor: 3.725

6.  Evolution of haemodynamics and outcome of fluid-refractory septic shock in children.

Authors:  Akash Deep; Chulananda D A Goonasekera; Yanzhong Wang; Joe Brierley
Journal:  Intensive Care Med       Date:  2013-06-28       Impact factor: 17.440

7.  Pulmonary Artery Catheter (PAC) Accuracy and Efficacy Compared with Flow Probe and Transcutaneous Doppler (USCOM): An Ovine Cardiac Output Validation.

Authors:  Robert A Phillips; Sally G Hood; Beverley M Jacobson; Malcolm J West; Li Wan; Clive N May
Journal:  Crit Care Res Pract       Date:  2012-05-09

Review 8.  Neonatal liver failure: aetiologies and management--state of the art.

Authors:  Naresh P Shanmugam; Sanjay Bansal; Anne Greenough; Anita Verma; Anil Dhawan
Journal:  Eur J Pediatr       Date:  2010-10-02       Impact factor: 3.860

9.  Liver transplantation: Advances and perioperative care.

Authors:  Amar Nandhakumar; Stuart A McCluskey; Coimbatore Srinivas; Tony T Chandy
Journal:  Indian J Anaesth       Date:  2012-07

10.  Temporal haemodynamic changes after bisoprolol treatment in patients with uncontrolled hypertension.

Authors:  Weiwei Zeng; Brian Tomlinson
Journal:  Ann Transl Med       Date:  2021-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.