Literature DB >> 18573523

Effect of pulpal pressure on the microtensile bond strength of luting resin cements to human dentin.

N Hiraishi1, C K Y Yiu, N M King, F R Tay.   

Abstract

OBJECTIVES: The objectives of this study were to examine the effect of pulpal pressure on the microtensile bond strength (mTBS) of luting resin cements to human dentin and the permeability of dentin surfaces pre-treated with an adhesive and a self-etching primer.
METHODS: Cylindrical composite blocks were luted with resin cements (RelyX ARC, 3M ESPE: ARC; Panavia F, Kuraray Medical Inc.: PF; RelyX Unicem, 3M ESPE: UN) in the absence or presence of simulated pulpal pressure. The application of Adper Single Bond 2 (3M ESPE) and ED primer 2.0 (Kuraray) was performed under 0 cm H(2)O. After each resin cement was applied, the pulpal pressure group was subjected to 20 cm H(2)O of hydrostatic pressure for 10 min during the initial setting period. Testing for mTBS was performed on 0.9 mm x 0.9 mm sectioned beams after 24h water-storage. Scanning electron microscopy was performed to investigate the fractured surfaces after mTBS testing and additional dentin surfaces that were treated by an etchant, ED primer 2.0 and UN. Fluid permeability was measured on dentin surfaces that were applied with Adper Single Bond 2 and ED primer 2.0.
RESULTS: Application of pulpal pressure reduced mTBS significantly in groups ARC and PF. Porous bonding interfaces due to water permeability through the cured adhesive were observed on fractured surfaces. Dentin surfaces that were applied with the adhesive and the primer were more permeable than smear layer-covered dentin. The mTBS of UN was significantly lower than ARC and PF regardless of the absence/presence of pulpal pressure. SIGNIFICANCE: Fluid permeation during the initial setting period deteriorated the bonding quality of resin cements.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18573523     DOI: 10.1016/j.dental.2008.05.005

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  6 in total

1.  Four-year clinical evaluation of a self-adhesive luting agent for ceramic inlays.

Authors:  Marleen Peumans; M Voet; J De Munck; K Van Landuyt; A Van Ende; B Van Meerbeek
Journal:  Clin Oral Investig       Date:  2012-06-17       Impact factor: 3.573

2.  Bond strength of self-adhesive resin cements to different treated indirect composites.

Authors:  M Victoria Fuentes; Laura Ceballos; Santiago González-López
Journal:  Clin Oral Investig       Date:  2012-05-23       Impact factor: 3.573

3.  [Effect of intrapulpal pressure on the bonding strength of resin cement to dentin].

Authors:  Y X Pan; X H Li; F C Tian; X Y Wang
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2019-04-18

4.  'Wet or Dry tooth surface?' - for self-adhesive resin cement.

Authors:  Jeong-Won Park
Journal:  Restor Dent Endod       Date:  2012-11-21

Review 5.  Validity of bond strength tests: A critical review-Part II.

Authors:  Kantheti Sirisha; Tankonda Rambabu; Yalavarthi Ravishankar; Pabbati Ravikumar
Journal:  J Conserv Dent       Date:  2014-09

6.  Effect of Two Immediate Dentin Sealing Approaches on Bond Strength of Lava™ CAD/CAM Indirect Restoration.

Authors:  Hassan Faez Abdullah Gailani; Cristina Benavides-Reyes; María Victoria Bolaños-Carmona; Eva Rosel-Gallardo; Purificación González-Villafranca; Santiago González-López
Journal:  Materials (Basel)       Date:  2021-03-26       Impact factor: 3.623