Literature DB >> 18562779

Attenuation correction of four dimensional (4D) PET using phase-correlated 4D-computed tomography.

Falk Pönisch1, Christian Richter, Uwe Just, Wolfgang Enghardt.   

Abstract

The image quality in a conventional positron emission tomography (PET)/computed tomography (CT) scanner is degraded by respiratory motion because of erroneous attenuation correction when three-dimensional image acquisition is used. To overcome this problem, time-resolved data acquisition (4D) is required. For this, a Siemens Biograph 16 PET/CT scanner has been modified and its normal capability has been extended to a true 4D-PET/4D-CT imaging device including phase-correlated attenuation correction. To verify the correct functionality of this device, experiments on a respiratory motion phantom that allowed movement in two dimensions have been performed. The measurements showed good spatial correlation as well as good time synchronization between the PET and CT data. Furthermore, the motion pattern of the phantom and the shape of the activity distribution have been examined, and the volume of the reconstructed PET images has been analyzed. The results demonstrate the feasibility of such a procedure, and we therefore recommend that 4D-PET data should be reconstructed using 4D-CT data, which can be acquired on the same machine.

Mesh:

Year:  2008        PMID: 18562779     DOI: 10.1088/0031-9155/53/13/N03

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

Review 1.  Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques.

Authors:  Matthias Hofmann; Bernd Pichler; Bernhard Schölkopf; Thomas Beyer
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

Review 2.  Current state of hybrid imaging: attenuation correction and fusion.

Authors:  Jonathon A Nye; Tracy L Faber
Journal:  J Nucl Cardiol       Date:  2011-05-07       Impact factor: 5.952

3.  Impact of CT attenuation correction method on quantitative respiratory-correlated (4D) PET/CT imaging.

Authors:  Matthew J Nyflot; Tzu-Cheng Lee; Adam M Alessio; Scott D Wollenweber; Charles W Stearns; Stephen R Bowen; Paul E Kinahan
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

4.  Techniques for respiration-induced artifacts reductions in thoracic PET/CT.

Authors:  Tao Sun; Greta S P Mok
Journal:  Quant Imaging Med Surg       Date:  2012-03

5.  The potential of positron emission tomography for intratreatment dynamic lung tumor tracking: a phantom study.

Authors:  Jaewon Yang; Tokihiro Yamamoto; Samuel R Mazin; Edward E Graves; Paul J Keall
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

6.  Optimal gating compared to 3D and 4D PET reconstruction for characterization of lung tumours.

Authors:  Wouter van Elmpt; James Hamill; Judson Jones; Dirk De Ruysscher; Philippe Lambin; Michel Ollers
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-01-11       Impact factor: 9.236

Review 7.  Advances in 4D radiation therapy for managing respiration: part I - 4D imaging.

Authors:  Geoffrey D Hugo; Mihaela Rosu
Journal:  Z Med Phys       Date:  2012-07-10       Impact factor: 4.820

8.  Motion artifacts occurring at the lung/diaphragm interface using 4D CT attenuation correction of 4D PET scans.

Authors:  Joseph H Killoran; Victor H Gerbaudo; Marcelo Mamede; Dan Ionascu; Sang-June Park; Ross Berbeco
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

9.  Impact of moving target on measurement accuracy in 3D and 4D PET imaging-a phantom study.

Authors:  Yunfeng Cui; James Bowsher; Jing Cai; Fang-Fang Yin
Journal:  Adv Radiat Oncol       Date:  2016-12-10

10.  Comparing approaches to correct for respiratory motion in NH3 PET-CT cardiac perfusion imaging.

Authors:  Paul J Schleyer; Michael J O'Doherty; Sally F Barrington; Geraint Morton; Paul K Marsden
Journal:  Nucl Med Commun       Date:  2013-12       Impact factor: 1.690

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.