Literature DB >> 18562085

A passive acoustic device for real-time monitoring of the efficacy of shockwave lithotripsy treatment.

T G Leighton1, F Fedele, A J Coleman, C McCarthy, S Ryves, A M Hurrell, A De Stefano, P R White.   

Abstract

Extracorporeal shockwave lithotripsy (ESWL) is the preferred modality for the treatment of renal and ureteric stone disease. Currently X-ray or ultrasound B-scan imaging are used to locate the stone and to check that it remains targeted at the focus of the lithotripter during treatment. Neither imaging modality is particularly effective in allowing the efficacy of treatment to be judged during the treatment session. A new device is described that, when placed on the patient's skin, can passively monitor the acoustic signals that propagate through the body after each lithotripter shock, and which can provide useful information on the effectiveness of targeting. These acoustic time histories are analyzed in real time to extract the two main characteristic peak amplitudes (m(1) and m(2)) and the time between these peaks (t(c)). A set of rules based on the acoustic parameters was developed during a clinical study in which a complete set of acoustic and clinical data was obtained for 30 of the 118 subjects recruited. The rules, which complied with earlier computational fluid dynamics (CFD) modeling and in vitro tests, allow each shock to be classified as "effective" or "ineffective." These clinically-derived rules were then applied in a second clinical study in which complete datasets were obtained for 49 of the 85 subjects recruited. This second clinical study demonstrated almost perfect agreement (kappa = 0.94) between the number of successful treatments, defined as >50% fragmentation as determined by X-ray at the follow-up appointment, and a device-derived global treatment score, TS(0), a figure derived from the total number of effective shocks in any treatment. The acoustic system is shown to provide a test of the success of the treatment that has a sensitivity of 91.7% and a specificity of 100%. In addition to the predictive capability, the device provides valuable real-time feedback to the lithotripter operator by indicating the effectiveness of each shock, plus an indication TS(t) of the cumulative effectiveness of the shocks given so far in any treatment, and trends in key parameters. This feedback would allow targeting adjustments to be made during treatment. An example is given of its application to mistargeting because of respiration. tgl@soton.ac.uk

Entities:  

Mesh:

Year:  2008        PMID: 18562085     DOI: 10.1016/j.ultrasmedbio.2008.03.011

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  12 in total

1.  Bubble dynamics in a compressible liquid in contact with a rigid boundary.

Authors:  Qianxi Wang; Wenke Liu; A M Zhang; Yi Sui
Journal:  Interface Focus       Date:  2015-10-06       Impact factor: 3.906

2.  A heuristic model of stone comminution in shock wave lithotripsy.

Authors:  Nathan B Smith; Pei Zhong
Journal:  J Acoust Soc Am       Date:  2013-08       Impact factor: 1.840

3.  Comparison of Broad vs Narrow Focal Width Lithotripter Fields.

Authors:  Yifei Xing; Tony T Chen; Walter N Simmons; Georgy Sankin; Franklin H Cocks; Michael E Lipkin; Glenn M Preminger; Pei Zhong
Journal:  J Endourol       Date:  2017-04-21       Impact factor: 2.942

Review 4.  For Whom the Bubble Grows: Physical Principles of Bubble Nucleation and Dynamics in Histotripsy Ultrasound Therapy.

Authors:  Kenneth B Bader; Eli Vlaisavljevich; Adam D Maxwell
Journal:  Ultrasound Med Biol       Date:  2019-03-26       Impact factor: 2.998

5.  Improving the lens design and performance of a contemporary electromagnetic shock wave lithotripter.

Authors:  Andreas Neisius; Nathan B Smith; Georgy Sankin; Nicholas John Kuntz; John Francis Madden; Daniel E Fovargue; Sorin Mitran; Michael Eric Lipkin; Walter Neal Simmons; Glenn M Preminger; Pei Zhong
Journal:  Proc Natl Acad Sci U S A       Date:  2014-03-17       Impact factor: 11.205

6.  Cavitation-induced damage of soft materials by focused ultrasound bursts: A fracture-based bubble dynamics model.

Authors:  Pooya Movahed; Wayne Kreider; Adam D Maxwell; Shelby B Hutchens; Jonathan B Freund
Journal:  J Acoust Soc Am       Date:  2016-08       Impact factor: 1.840

7.  In Vitro Evaluation of Urinary Stone Comminution with a Clinical Burst Wave Lithotripsy System.

Authors:  Shivani Ramesh; Tony T Chen; Adam D Maxwell; Bryan W Cunitz; Barbrina Dunmire; Jeff Thiel; James C Williams; Anthony Gardner; Ziyue Liu; Ian Metzler; Jonathan D Harper; Mathew D Sorensen; Michael R Bailey
Journal:  J Endourol       Date:  2020-03-20       Impact factor: 2.942

Review 8.  Shock wave technology and application: an update.

Authors:  Jens J Rassweiler; Thomas Knoll; Kai-Uwe Köhrmann; James A McAteer; James E Lingeman; Robin O Cleveland; Michael R Bailey; Christian Chaussy
Journal:  Eur Urol       Date:  2011-02-23       Impact factor: 20.096

9.  A PVDF receiver for ultrasound monitoring of transcranial focused ultrasound therapy.

Authors:  Meaghan A O'Reilly; Kullervo Hynynen
Journal:  IEEE Trans Biomed Eng       Date:  2010-05-27       Impact factor: 4.538

Review 10.  Shock wave lithotripsy: advances in technology and technique.

Authors:  James E Lingeman; James A McAteer; Ehud Gnessin; Andrew P Evan
Journal:  Nat Rev Urol       Date:  2009-12       Impact factor: 14.432

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.